1.
Int J Spine Surg ; 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38866587

ABSTRACT

BACKGROUND: Anterior cervical discectomy and fusion (ACDF) is known to elicit adverse biomechanical effects on immediately adjacent segments; however, its impact on the kinematics of the remaining nonadjacent cervical levels has not been understood. This study aimed to explore the biomechanical impact of ACDF on kinematics beyond the immediate fusion site. We hypothesized that compensatory motion following single-level ACDF is not predictably distributed to adjacent segments due to compensation from noncontiguous levels. METHODS: Six fresh-frozen cervical spines (C2-T1) underwent fluoroscopic screening and sagittal and coronal reformats from computed tomography scans and were utilized to grade segmental degeneration. Each specimen was tested to 30° of flexion and extension intact and following single-level ACDF at the C5-C6 level. The motions of each vertebral body were tracked using 3-dimensional (3D) motion capture into an inverse kinematics model, facilitating correlations between the 3D reconstruction from computed tomography images and the 3D motion capture data. This model was used to calculate each level's flexion/extension range of motion (ROM). RESULTS: Single-level fusion at the C5-C6 level across all specimens resulted in a significant motion reduction of -6.8° (P = 0.002). No significant change in ROM occurred in the immediate adjacent segments C4-C5 (P = 0.07) or C6-C7 (P = 0.15). Hypermobility was observed in 2 specimens (33%) exclusively in adjacent segments. In contrast, the other 4 spines (66%) displayed hypermobility at noncontiguous segments. Hypermobility occurred in 42% (5/12) of the adjacent segments, 28% (5/18) of the noncontiguous segments, and 50% (3/6) of the cervicothoracic segments. CONCLUSION: Single-level ACDF impacts ROM beyond adjacent segments, extending to noncontiguous levels. Compensatory motion, not limited to adjacent levels, may be influenced by degenerative changes in noncontiguous segments. Surprisingly, hypermobility may not occur in adjacent segments after ACDF. CLINICAL RELEVANCE: Overall, the multifaceted biomechanical effects of ACDF underscore the need for a comprehensive understanding of cervical spine dynamics beyond immediate adjacency, and it needs to be taken into consideration when planning single-level ACDF.

2.
Article in English | MEDLINE | ID: mdl-38819199

ABSTRACT

STUDY DESIGN: Retrospective Database review. OBJECTIVE: Analyze revisions of CDAs reported to the MAUDE database. SUMMARY OF BACKGROUND DATA: Cervical disc arthroplasty (CDA) has emerged as a motion-preserving alternative to anterior cervical discectomy and fusion (ACDF) for degenerative cervical disease, demonstrating comparable outcomes. Despite the availability of variable CDA designs, there is limited data on the specific complications of individual CDAs. The Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database has been used to systematically report complications associated with CDAs. However, data on specific reasons for CDA revision remains scarce. The purpose of this study is to compare common complications associated with revision for different CDAs. METHODS: The MAUDE database was queried from January 2005 to September 2023, including all nine FDA-approved CDAs. The full-text reports of each complication were categorized based on whether revision surgery was performed, the complications and the type of CDA collected and compared. RESULTS: A total of 678 revisions for nine CDAs were reported: Mobi-C (239), M6 (167), Prodisc-C (88), Prestige (60), PCM (44), Bryan (35), Secure (23), Simplify (21), and Discover (1). The top three complications associated with revision were migration (23.5%), neck pain (15.5%), and heterotopic ossification (6.6%). The most common complications per device were migration for Mobi-C (26.4%), Prodisc-C (21.3%), Prestige (24.6%), PCM (84.1%), Bryan (48.6%), Secure (30.4%), and Discover (100%). For M6, the most common complications associated with revision surgery were osteolysis (18.6%) and neck pain (18.6%), while neck pain (23.8%) was the most common for the Simplify. CONCLUSION: The MAUDE database highlights complications related to CDA revision in which the primary complications consistently include implant migration, neck pain, and heterotopic ossification ,varying in their rerelvance depending on the CDA.

3.
J Neurosurg Case Lessons ; 7(17)2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38648675

ABSTRACT

BACKGROUND: Radicular pain after lumbar decompression surgery can result from epidural hematoma/seroma, recurrent disc herniation, incomplete decompression, or other rare complications. A less recognized complication is postoperative nerve root herniation, resulting from an initially unrecognized intraoperative or, more commonly, a spontaneous postoperative durotomy. Rarely, this nerve root herniation can become entrapped within local structures, including the facet joint. The aim of this study was to illustrate our experience with three cases of lumbosacral nerve root eventration into an adjacent facet joint and to describe our diagnostic and surgical approach to this rare complication. OBSERVATIONS: Three patients who had undergone lumbar decompression surgery with or without fusion experienced postoperative radiculopathy. Exploratory revision surgery revealed all three had a durotomy with nerve root eventration into the facet joint. Significant symptom improvement was achieved in all patients following liberation of the neural elements from the facet joints. LESSONS: Entrapment of herniated nerve roots into the facet joint may be a previously underappreciated complication and remains quite challenging to diagnose even with the highest-quality advanced imaging. Thus, clinicians must have a high index of suspicion to diagnose this issue and a low threshold for surgical exploration.

4.
Global Spine J ; : 21925682241232328, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38324511

ABSTRACT

STUDY DESIGN: Human Cadaveric Study. OBJECTIVE: This study aims to explore the feasibility of using preoperative magnetic resonance imaging (MRI), zero-time-echo (ZTE) and spoiled gradient echo (SPGR), as source data for robotic-assisted spine surgery and assess the accuracy of pedicle screws. METHODS: Zero-time-echo and SPGR MRI scans were conducted on a human cadaver. These images were manually post-processed, producing a computed tomography (CT)-like contrast. The Mazor X robot was used for lumbar pedicle screw-place navigating of MRI. The cadaver underwent a postoperative CT scan to determine the actual position of the navigated screws. RESULTS: Ten lumbar pedicle screws were robotically navigated of MRI (4 ZTE; 6 SPGR). All MR-navigated screws were graded A on the Gertzbein-Robbins scale. Comparing preoperative robotic planning to postoperative CT scan trajectories: The screws showed a median deviation of overall 0.25 mm (0.0; 1.3), in the axial plane 0.27 mm (0.0; 1.3), and in the sagittal plane 0.24 mm (0.0; 0.7). CONCLUSION: This study demonstrates the first successful registration of MRI sequences, ZTE and SPGR, in robotic spine surgery here used for intraoperative navigation of lumbar pedicle screws achieving sufficient accuracy, showcasing potential progress toward radiation-free spine surgery.

6.
Radiol Clin North Am ; 62(2): 217-228, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38272616

ABSTRACT

Chronic low back pain is a major source of pain and disability globally involving multifactorial causes. Historically, intervertebral disc degeneration and disruption have been associated as primary back pain triggers of the anterior column, termed "discogenic pain." Recently, the vertebral endplates have been identified as another possible pain trigger of the anterior column. This "endplate-driven" model, defined "vertebrogenic pain," is often interconnected with disc degeneration. Diagnosis of vertebrogenic and discogenic pain relies on imaging techniques that isolate pain generators and exclude comorbid conditions. Traditional methods, like radiographs and discography, are augmented by more sensitive methods, including SPECT, CT, and MRI. Morphologic MRI is pivotal in revealing indicators of vertebrogenic (eg, Modic endplate changes) and discogenic pain (eg, disc degeneration and annular fissures). More advanced methods, like ultra-short-echo time imaging, and quantitative MRI further amplify MRI's accuracy in the detection of painful endplate and disc pathology. This review explores the pathophysiology of vertebrogenic and discogenic pain as well as the impact of different imaging modalities in the diagnosis of low back pain. We hope this information can help identify patients who may benefit from personalized clinical treatment and image-guided therapies.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Low Back Pain , Humans , Intervertebral Disc Degeneration/complications , Intervertebral Disc Degeneration/diagnostic imaging , Intervertebral Disc Degeneration/pathology , Intervertebral Disc/diagnostic imaging , Intervertebral Disc/pathology , Low Back Pain/diagnostic imaging , Low Back Pain/etiology , Radiography , Magnetic Resonance Imaging/adverse effects
7.
Sci Rep ; 13(1): 22660, 2023 12 19.
Article in English | MEDLINE | ID: mdl-38114733

ABSTRACT

The aim of this study was to determine tissue-specific blood perfusion impairment of the cervical cord above the compression site in patients with degenerative cervical myelopathy (DCM) using intravoxel incoherent motion (IVIM) imaging. A quantitative MRI protocol, including structural and IVIM imaging, was conducted in healthy controls and patients. In patients, T2-weighted scans were acquired to quantify intramedullary signal changes, the maximal canal compromise, and the maximal cord compression. T2*-weighted MRI and IVIM were applied in all participants in the cervical cord (covering C1-C3 levels) to determine white matter (WM) and grey matter (GM) cross-sectional areas (as a marker of atrophy), and tissue-specific perfusion indices, respectively. IVIM imaging resulted in microvascular volume fraction ([Formula: see text]), blood velocity ([Formula: see text]), and blood flow ([Formula: see text]) indices. DCM patients additionally underwent a standard neurological clinical assessment. Regression analysis assessed associations between perfusion parameters, clinical outcome measures, and remote spinal cord atrophy. Twenty-nine DCM patients and 30 healthy controls were enrolled in the study. At the level of stenosis, 11 patients showed focal radiological evidence of cervical myelopathy. Above the stenosis level, cord atrophy was observed in the WM (- 9.3%; p = 0.005) and GM (- 6.3%; p = 0.008) in patients compared to healthy controls. Blood velocity (BV) and blood flow (BF) indices were decreased in the ventral horns of the GM (BV: - 20.1%, p = 0.0009; BF: - 28.2%, p = 0.0008), in the ventral funiculi (BV: - 18.2%, p = 0.01; BF: - 21.5%, p = 0.04) and lateral funiculi (BV: - 8.5%, p = 0.03; BF: - 16.5%, p = 0.03) of the WM, across C1-C3 levels. A decrease in microvascular volume fraction was associated with GM atrophy (R = 0.46, p = 0.02). This study demonstrates tissue-specific cervical perfusion impairment rostral to the compression site in DCM patients. IVIM indices are sensitive to remote perfusion changes in the cervical cord in DCM and may serve as neuroimaging biomarkers of hemodynamic impairment in future studies. The association between perfusion impairment and cervical cord atrophy indicates that changes in hemodynamics caused by compression may contribute to the neurodegenerative processes in DCM.


Subject(s)
Cervical Cord , Musculoskeletal Diseases , Spinal Cord Compression , Spinal Cord Diseases , Humans , Constriction, Pathologic/pathology , Spinal Cord Diseases/diagnostic imaging , Spinal Cord Diseases/pathology , Spinal Cord Compression/diagnostic imaging , Spinal Cord Compression/pathology , Magnetic Resonance Imaging/methods , Cervical Cord/diagnostic imaging , Cervical Cord/pathology , Perfusion , Musculoskeletal Diseases/pathology , Atrophy/pathology , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/pathology
8.
Foot Ankle Orthop ; 7(2): 24730114221092021, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35520475

ABSTRACT

Background: Magnetic resonance imaging (MRI) is commonly used for evaluation of ankle cartilage repair, yet its association with clinical outcome is controversial. This study analyzes the correlation between MRI and clinical outcome after cartilage repair of the talus including bone marrow stimulation, cell-based techniques, as well as restoration with allo- or autografting. Methods: A systematic search was performed in MEDLINE, Embase, and Cochrane Collaboration. Articles were screened for correlation of MRI and clinical outcome. Guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) were used. Chi-square test and regression analysis were performed to identify variables that determine correlation between clinical and radiologic outcome. Results: Of 2687 articles, a total of 43 studies (total 1212 cases) were included with a mean Coleman score of 57 (range, 33-70). Overall, 93% were case series, and 5% were retrospective and 2% prospective cohort studies. Associations between clinical outcome and ≥1 imaging variable were found in 21 studies (49%). Of 24 studies (56%) using the composite magnetic resonance observation of cartilage repair tissue (MOCART) score, 7 (29%) reported a correlation of the composite score with clinical outcome. Defect fill was associated with clinical outcome in 5 studies (12%), and 5 studies (50%) reported a correlation of T2 mapping and clinical outcome. Advanced age, shorter follow-up, and larger study size were associated with established correlation between clinical and radiographic outcome (P = .021, P = .028, and P = .033). Conclusion: Interpreting MRI in prediction of clinical outcome in ankle cartilage repair remains challenging; however, it seems to hold some value in reflecting clinical outcome in patients with advanced age and/or at a shorter follow-up. Yet, further research is warranted to optimize postoperative MRI protocols and assessments allowing for a more comprehensive repair tissue evaluation, which eventually reflect clinical outcome in patients after cartilage repair of the ankle.Level of Evidence: Level III, systematic review and meta-analysis.

9.
Spine J ; 22(1): 75-83, 2022 01.
Article in English | MEDLINE | ID: mdl-34284130

ABSTRACT

BACKGROUND CONTEXT: Early postoperative MR images are frequently necessary after spine surgery. The appearance of commonly used adjunct hemostatic agents and dural sealants in MR images has not been systematically evaluated. PURPOSE: The purpose of this experimental study was to systematically analyze and describe the characteristics of the most commonly applied hemostatic agents and dural sealants in spine surgery on early postoperative MR images. STUDY DESIGN: Cadaver Study METHODS: Four commonly applied dural sealants (Duraseal, Bioglue, Tachosil, Tisseel) and five commonly used hemostatic agents (Surgiflo, Bonewax, , Spongostan, Gelfoam, Avitene) were investigated. The experimental setting involved a human cadaver where a standard left-sided laminotomy was performed on nine levels of the thoracolumbar spine, and the materials were separately applied and mixed with fresh blood or water for hemostatic and dural sealants, respectively. The cadaver model was scanned at a 3 Tesla MRI and the imaging findings for all materials were compared to the surrounding tissue and systematically reported. RESULTS: All investigated dural sealants and hemostatic agents were distinguishable from the surrounding tissue on MR images with different appearances on the MR sequences. A detailed atlas for the identification of the materials in postoperative spine MRI was established. CONCLUSION: Commonly used hemostatic agents and dural sealants can be successfully identified on early postoperative spine MRI. CLINICAL SIGNIFICANCE: Knowledge about MRI appearances of commonly used adjunct surgical materials helps in interpretation of postoperative imaging and supports clinical decision making.


Subject(s)
Fibrin Tissue Adhesive , Hemostatics , Humans , Laminectomy , Magnetic Resonance Imaging , Postoperative Period
SELECTION OF CITATIONS
SEARCH DETAIL
...