Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Case Rep Surg ; 2019: 4036823, 2019.
Article in English | MEDLINE | ID: mdl-30963015

ABSTRACT

Although Schistosoma infection in humans commonly involves the intestines, megacolon is a rare finding. We report a 47-year-old patient who was found to have chronic megacolon. After failing conservative management, he underwent extended hemicolectomy with colorectal anastomosis. The colon pathology revealed chronic schistosomiasis and Schistosoma serology was positive.

2.
BMC Anesthesiol ; 15: 147, 2015 Oct 15.
Article in English | MEDLINE | ID: mdl-26471790

ABSTRACT

BACKGROUND: Maintaining the cuff pressure of endotracheal tubes (ETTs) within 20-30 cmH2O is a standard practice. The aim of the study was to evaluate the effectiveness of standard practice in maintaining cuff pressure within the target range. METHODS: This was a prospective observational study conducted in a tertiary-care intensive care unit, in which respiratory therapists (RTs) measured the cuff pressure 6 hourly by a handheld manometer. In this study, a research RT checked cuff pressure 2-4 h after the clinical RT measurement. Percentages of patients with cuff pressure levels above and below the target range were calculated. We identified predictors of low-cuff pressure. RESULTS: We analyzed 2120 cuff-pressure measurements. The mean cuff pressure was 27 ± 2 cmH2O by the clinical RT and 21 ± 5 cmH2O by the research RT (p < 0.0001). The clinical RT documented that 98.0 % of cuff pressures were within the normal range. The research RT found the cuff pressures to be within the normal range in only 41.5 %, below the range in 53 % and above the range in 5.5 %. Low cuff pressure was found more common with lower ETT size (OR, 0.34 per 0.5 unit increase in ETT size; 95 % CI, 0.15-0.79) and with lower peak airway pressure (OR per one cm H2O increment, 0.93; 95 % CI, 0.87-0.99) on multivariate analysis. CONCLUSIONS: Cuff pressure is frequently not maintained within the target range with low-cuff pressure being very common approximately 3 h after routine measurements. Low cuff pressure was associated with lower ETT size and lower peak airway pressure. There is a need to redesign the process for maintaining cuff pressure within the target range.


Subject(s)
Intubation, Intratracheal/instrumentation , Monitoring, Intraoperative/methods , Pressure , Respiration, Artificial/instrumentation , Tracheostomy/instrumentation , Adult , Aged , Cohort Studies , Female , Humans , Intubation, Intratracheal/methods , Male , Manometry/instrumentation , Manometry/methods , Middle Aged , Predictive Value of Tests , Prevalence , Prospective Studies , Respiration, Artificial/methods , Tracheostomy/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...