Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Clin Med Phys ; 20(8): 29-35, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31313508

ABSTRACT

Recently, there has been an increased interest in the feasibility and impact of automation within the field of medical dosimetry. While there have been many commercialized solutions for automatic treatment planning, the use of an application programming interface to achieve complete plan generation for specific treatment sites is a process only recently available for certain commercial vendors. Automatic plan generation for 20 prostate patients was achieved via a stand-alone automated planning script that accessed a knowledge-based planning solution. Differences between the auto plans and clinically treated, baseline plans were analyzed and compared. The planning script successfully initialized a treatment plan, accessed the knowledge-based planning model, optimized the plan, assessed for constraint compliance, and normalized the treatment plan for maximal coverage while meeting constraints. Compared to baseline plans, the auto-generated plans showed significantly improved rectal sparing with similar coverage for targets and comparable doses to the remaining organs-at-risk. Utilization of a script, with its associated time saving and integrated process management, can quickly and automatically generate an acceptable clinical treatment plan for prostate cancer with either improved or similar results compared to a manually created plan.


Subject(s)
Automation , Patient Care Planning/standards , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/standards , Radiotherapy, Intensity-Modulated/methods , Algorithms , Humans , Knowledge Bases , Male , Radiotherapy Dosage , Software
2.
Radiol Oncol ; 49(3): 291-8, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26401136

ABSTRACT

BACKGROUND: Volumetric modulated arc therapy (VMAT) has quickly become accepted as standard of care for the treatment of prostate cancer based on studies showing it is able to provide faster delivery with adequate target coverage and reduced monitor units while maintaining organ at risk (OAR) sparing. This study aims to demonstrate the potential to increase dose conformality with increased planner control and OAR sparing using a hybrid treatment technique compared to VMAT. METHODS: Eleven patients having been previously treated for prostate cancer with VMAT techniques were replanned with a hybrid technique on Varian Treatment Planning System. Multiple static IMRT fields (2 to 3) were planned initially based on critical OAR to reduce dose but provide some planning treatment volume (PTV) coverage. This was used as a base dose plan to provide 30-35% coverage for a single arc VMAT plan. RESULTS: The clinical VMAT plan was used as a control for the purposes of comparison. Average of all OAR sparing between the hybrid technique and VMAT showed the hybrid plan delivering less dose in almost all cases except for V80 of the bladder and maximum dose to right femoral head. PTV coverage was superior with the VMAT technique. Monitor unit differences varied, with the hybrid plan able to deliver fewer units 37% of the time, similar results 18% of the time, and higher units 45% of the time. On average, the hybrid plan delivered 10% more monitor units. CONCLUSIONS: The hybrid plan can be delivered in a single gantry rotation combining aspects of VMAT with regions of dynamic intensity modulated radiation therapy (IMRT) within the treatment arc.

SELECTION OF CITATIONS
SEARCH DETAIL
...