Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Preprint in English | bioRxiv | ID: ppbiorxiv-515436

ABSTRACT

We analyzed the dynamics of the earliest T cell response to SARS-COV-2. A wave of TCRs strongly but transiently expand during infection, frequently peaking the same week as the first positive PCR test. These expanding TCR CDR3s were enriched for sequences functionally annotated as SARS-COV-2 specific. Most epitopes recognized by the expanding TCRs were highly conserved between SARS-COV-2 strains, but not with circulating human coronaviruses. Many expanding CDR3s were also present at high precursor frequency in pre-pandemic TCR repertoires. A similar set of early response TCRs specific for lymphocytic choriomeningitis virus epitopes were also found at high frequency in the pre-infection naive repertoire. High frequency naive precursors may allow the T cell response to respond rapidly during the crucial early phases of acute viral infection. One-Sentence SummaryHigh frequency naive precursors underly the rapid T cell response during the crucial early phases of acute viral infection.

2.
Preprint in English | medRxiv | ID: ppmedrxiv-22274025

ABSTRACT

BackgroundUnderstanding immunological responses to SARS-CoV-2 vaccinations is integral to the management of SARS-CoV-2. We aimed to investigate determinants of antibody response to the BNT162b2 vaccine. MethodsA cross-sectional analysis of anti-spike binding antibodies in serum samples from healthcare workers after one or two doses. Post-vaccination interval was restricted to [≥]21 days after dose 1, [≥]14 days after dose 2. The primary outcome was anti-S titres with explanatory variables dose, previous infection, dosing interval, age, ethnicity, and comorbidities. Multivariable linear regression was also conducted. ResultsParticipants (n=5,871) included 3,989 post-dose 1, 1,882 post-dose 2. In SARS-CoV-2 infection naive, 99.65% seroconverted after dose 1 and >99.9% seroconverted after dose 2. Geometric mean anti-S titre in the naive cohort was 75.48 Binding Antibody Units/ml after dose 1, 7,049 BAU/ml after dose 2. Anti-S titres were higher in those with previous infection (2,111 BAU/ml post-dose 1, 16,052 BAU/ml post-dose 2), and increased with time between infection and vaccination: 3 months 1,970 (1,506-2,579) vs 9 months; 13,759 (8,097-23,379). Longer dosing intervals increased antibody response post-dose 2: 11-fold higher with a longer interval (>10 weeks) than those with shorter intervals, across all age-groups. Younger participants had higher mean titres (>2.2-fold higher). Multivariable regression modelling corroborated the above associations, and also found higher titres associated with being female or from an ethnic minority but lower titres among immunocompromised participants. ConclusionThe number of antigen exposures and timing between vaccinations plays a significant role in the magnitude of the post-vaccination antibody response, with implications for long-term protection and post-booster antibody responses.

3.
Preprint in English | medRxiv | ID: ppmedrxiv-22270845

ABSTRACT

Determining the protection an individual has to SARS-CoV-2 variants of concern (VoC) will be crucial for future immune surveillance and understanding the changing immune response. As further variants emerge, current serology tests are becoming less effective in reflecting neutralising capability of the immune system. A better measure of an evolving antigen-antibody immune response is needed. We describe a multiplexed, baited, targeted-proteomic assay for direct detection of multiple proteins in the SARS-CoV-2 anti-spike antibody immunocomplex. This enables a more sophisticated and informative characterisation of the antibody response to vaccination and infection against VoC. Using this assay, we detail different and specific responses to each variant by measuring several antibody classes, isotypes and associated complement binding. Furthermore, we describe how these proteins change using serum from individuals collected after infection, first and second dose vaccination. We show complete IgG1 test concordance with gold standard ELISA (r>0.8) and live virus neutralisation against Wuhan Hu-1, Alpha B.1.1.7, Beta B.1.351, and Delta B.1.617.1 variants (r>0.79). We also describe a wide degree of heterogeneity in the immunocomplex of individuals and a greater IgA response in those patients who had a previous infection. Significantly, our test points to an important role the complement system may play particularly against VoC. Where we observe altered Complement C1q association to the Delta VoC response and a stronger overall association with neutralising antibodies than IgG1. A detailed understanding of an individuals antibody response could benefit public health immunosurveillance, vaccine design and inform vaccination dosing using a personalised medicine approach.

4.
Preprint in English | medRxiv | ID: ppmedrxiv-21267006

ABSTRACT

BackgroundUnderstanding the duration and effectiveness of infection and vaccine-acquired SARS-CoV-2 immunity is essential to inform pandemic policy interventions, including the timing of vaccine-boosters. We investigated this in our large prospective cohort of UK healthcare workers undergoing routine asymptomatic PCR testing. MethodsWe assessed vaccine effectiveness (VE) (up to 10-months after first dose) and infection-acquired immunity by comparing time to PCR-confirmed infection in vaccinated and unvaccinated individuals using a Cox regression-model, adjusted by prior SARS-CoV-2 infection status, vaccine-manufacturer/dosing-interval, demographics and workplace exposures. ResultsOf 35,768 participants, 27% (n=9,488) had a prior SARS-CoV-2 infection. Vaccine coverage was high: 97% had two-doses (79% BNT162b2 long-interval, 8% BNT162b2 short-interval, 8% ChAdOx1). There were 2,747 primary infections and 210 reinfections between 07/12/2020 and 21/09/2021. Adjusted VE (aVE) decreased from 81% (95% CI 68%-89%) 14-73 days after dose-2 to 46% (95% CI 22%-63%) >6-months; with no significant difference for short-interval BNT162b2 but significantly lower aVE (50% (95% CI 18%-70%) 14-73 days after dose-2 from ChAdOx1. Protection from infection-acquired immunity showed evidence of waning in unvaccinated follow-up but remained consistently over 90% in those who received two doses of vaccine, even in those infected over 15-months ago. ConclusionTwo doses of BNT162b2 vaccination induce high short-term protection to SARS-CoV-2 infection, which wanes significantly after six months. Infection-acquired immunity boosted with vaccination remains high over a year after infection. Boosters will be essential to maintain protection in vaccinees who have not had primary infection to reduce infection and transmission in this population. Trial registration numberISRCTN11041050

5.
Preprint in English | medRxiv | ID: ppmedrxiv-21265497

ABSTRACT

1.In March 2020, the Rare and Imported Pathogens Laboratory at Public Health England, Porton Down, was tasked by the Department of Health and Social Care with setting up a national surveillance laboratory facility to study SARS-CoV-2 antibody responses and population-level sero-surveillance in response to the growing SARS-CoV-2 outbreak. In the following 12 months, the laboratory tested more than 160,000 samples, facilitating a wide range of research and informing PHE, DHSC and UK government policy. Here we describe the implementation and use of the Euroimmun anti-SARS-CoV-2 IgG assay and provide an extended evaluation of its performance. We present a markedly improved sensitivity of 91.39% ([≥]14 days 92.74%, [≥]21 days 93.59%) compared to our small-scale early study, and a specificity of 98.56%. In addition, we detail extended characteristics of the Euroimmun assay: intra- and inter-assay precision, correlation to neutralisation and assay linearity.

6.
Preprint in English | medRxiv | ID: ppmedrxiv-21257572

ABSTRACT

Precision monitoring of antibody responses during the COVID-19 pandemic is increasingly important during large scale vaccine rollout and rise in prevalence of Severe Acute Respiratory Syndrome-related Coronavirus-2 (SARS-CoV-2) variants of concern (VOC). Equally important is defining Correlates of Protection (CoP) for SARS-CoV-2 infection and COVID-19 disease. Data from epidemiological studies and vaccine trials identified virus neutralising antibodies (Nab) and SARS-CoV-2 antigen-specific (notably RBD, and S) binding antibodies as candidate CoP. In this study, we used the World Health Organisation (WHO) international standard to benchmark neutralising antibody responses and a large panel of binding antibody assays to compare convalescent sera obtained from: a) COVID-19 patients; b) SARS-CoV-2 seropositive healthcare workers (HCW) and c) seronegative HCW. The ultimate aim of this study, was to identify biomarkers of humoral immunity that could be used as candidate CoP in internationally accepted unitage. Whenever suitable, the antibody levels of the samples studied were expressed in International Units (INU) for virus neutralisation assays or International Binding Antibody Units (BAU) for ELISA tests. In this work we used commercial and non-commercial antibody binding assays; a lateral flow test for detection of SARS-CoV-2-specific IgG / IgM; a high throughput multiplexed particle flow cytometry assay for SARS-CoV-2 Spike (S), Nucleocapsid (N) and Receptor Binding Domain (RBD) proteins); a multiplex antigen semi-automated immuno-blotting assay measuring IgM, IgA and IgG; a pseudotyped microneutralisation test (pMN) and electroporation-dependent neutralisation assay (EDNA). Our results indicate that overall, severe COVID-19 patients showed statistically significantly higher levels of SARS-CoV-2-specific neutralising antibodies (average 1029 IU/ml) than those observed in seropositive HCW with mild or asymptomatic infections (379 IU/ml) and that clinical severity scoring, based on WHO guidelines was tightly correlated with neutralisation and RBD / S binding assays. In addition, there was a positive correlation between severity, N-antibody assays and intracellular virus neutralisation.

7.
Preprint in English | medRxiv | ID: ppmedrxiv-21254540

ABSTRACT

The correlates of natural protective immunity to SARS-CoV-2 in the majority who experience asymptomatic infection or non-severe disease are not fully characterised, and remain important as new variants emerge. We addressed this question using blood transcriptomics, multiparameter flow cytometry and T cell receptor (TCR) sequencing spanning the time of incident infection. We identified a type 1 interferon (IFN) response common to other acute respiratory viruses, and a cell proliferation response that discriminated SARS-CoV-2 from other viruses. These responses peaked by the time the virus was first detected, and in some preceded virus detection. Cell proliferation was most evident in CD8 T cells and associated with rapid expansion of SARS-CoV-2 reactive TCRs. We found an equally rapid increase in immunoglobulin transcripts, but circulating virus-specific antibodies lagged by 1-2 weeks. Our data support a protective role for rapid induction of type 1 IFN and CD8 T cell responses to SARS-CoV-2.

8.
Preprint in English | medRxiv | ID: ppmedrxiv-20225920

ABSTRACT

BackgroundSARS-CoV-2 serology is used to identify prior infection at individual and at population level. Extended longitudinal studies with multi-timepoint sampling to evaluate dynamic changes in antibody levels are required to identify the time horizon in which these applications of serology are valid, and to explore the longevity of protective humoral immunity. MethodsHealth-care workers were recruited to a prospective cohort study from the first SARS-CoV-2 epidemic peak in London, undergoing weekly symptom screen, viral PCR and blood sampling over 16-21 weeks. Serological analysis (n=12,990) was performed using semi-quantitative Euroimmun IgG to viral spike S1 domain and Roche total antibody to viral nucleocapsid protein (NP) assays. Comparisons were made to previously reported pseudovirus neutralising antibody measurements. FindingsA total of 157/729 (21.5%) participants developed positive SARS-CoV-2 serology by one or other assay, of whom 31.0% were asymptomatic and there were no deaths. Peak Euroimmun anti-S1 and Roche anti-NP measurements correlated (r=0.57, p<0.0001) but only anti-S1 measurements correlated with near-contemporary pseudovirus neutralising antibody titres (measured at 16-18 weeks, r=0.57, p<0.0001). By 21 weeks follow-up, 31/143 (21.7%) anti-S1 and 6/150 (4.0%) anti-NP measurements reverted to negative. Mathematical modelling suggested faster clearance of anti-S1 compared to anti-NP (median half-life of 2.5 weeks versus 4.0 weeks), earlier transition to lower levels of antibody production (median of 8 versus 13 weeks), and greater reductions in relative antibody production rate after the transition (median of 35% versus 50%). InterpretationMild SARS-CoV-2 infection is associated with heterogenous serological responses in Euroimmun anti-S1 and Roche anti-NP assays. Anti-S1 responses showed faster rates of clearance, more rapid transition from high to low level production rate and greater reduction in production rate after this transition. The application of individual assays for diagnostic and epidemiological serology requires validation in time series analysis. FundingCharitable donations via Barts Charity Research in contextO_ST_ABSEvidence before this studyC_ST_ABSWe searched PubMed, medRxiv, and bioRxiv for ["antibody" OR "serology"] AND ["SARS-CoV-2" OR "COVID-19"]. The available literature highlights widespread use of serology to detect recent SARS-CoV-2 infection in individual patients and in population epidemiological surveys. Antibody to virus spike protein S1 domain is widely reported to correlate with neutralising antibody titres. The existing assays have good sensitivity to detect seroconversion within 14 days of incident infection, but the available longitudinal studies have reported variable rates of decline in antibody levels and reversion to undetectable levels in some people over 3 months. High frequency multi-time point serology data for different antibody targets or assays in longitudinal cohorts from the time of incident infection to greater than 3 months follow up are lacking. Added value of this studyWe combine detailed longitudinal serology using the Euroimmun anti-S1 and Roche anti-nucleocapsid protein (NP) assays in 731 health care workers from the time of the first SARS-CoV-2 epidemic peak in London, UK. In 157 seroconverters (using either assay) we show substantial heterogeneity in semiquantitative antibody measurements over time between individuals and between assays. Mathematical modelling of individual participant antibody production and clearance rates in individuals with at least 8 data points over 21 weeks showed anti-S1 antibodies to have a faster clearance rate, earlier transition from the initial antibody production rate to lower rates, and greater reduction in antibody production rate after this transition, compared to anti-NP antibodies as measured by these assays. As a result, Euroimmun anti-S1 measurements peaked earlier and then reduced more rapidly than Roche anti-NP measurements. In this study, these differences led to 21% anti-S1 sero-reversion, compared to 4% anti-NP sero-reversion over 4-5 months. Implications of all of the available evidenceThe rapid decline in anti-S1 antibodies measured by the Euroimmun assay following infection limits its application for diagnostic and epidemiological screening. If generalisable, these data are consistent with the hypothesis that anti-S1 mediated humoral immunity may not be sustained in some people beyond the initial post-infective period. Further work is required to understand the mechanisms behind the heterogeneity in antibody kinetics between individuals to SARS-CoV-2. Our data point to differential mechanisms regulating humoral immunity against these two viral targets.

9.
Preprint in English | medRxiv | ID: ppmedrxiv-20215228

ABSTRACT

BackgroundDried blood spot samples (DBS) provide an alternative sample type to venous blood samples for antibody testing. DBS are used by NHS for diagnosing HCV and by PHE for large scale HIV and Hepatitis C serosurveillance; the applicability of DBS based approaches to SARS-CoV-2 antibody detection is uncertain. ObjectiveTo compare antibody detection in dried blood spot eluates using the Roche Elecsys (R) immunoassay (index test) with antibody detection in paired plasma samples, using the same assay (reference test). SettingOne Police and one Fire & Rescue facility in England. Participants195 participants within a larger sample COVID-19 serodiagnostics study of keyworkers, EDSAB-HOME. Outcome MeasuresSensitivity and specificity of DBS (the index test) relative to plasma (the reference test), at an experimental cut-off; quality of DBS sample collected; estimates of relative sensitivity of DBS vs. plasma immunoassay in a larger population. Results18/195 (9.2%) participants tested positive using plasma samples. DBS sample quality varied markedly by phlebotomist, and low sample volume significantly reduced immunoassay signals. Using a cut-off of ten median absolute deviations above the immunoassay result with negative samples, sensitivity and specificity of DBS were 89.0% (95% CI 67.2, 96.9%) and 100.0% (95% CI 97.9, 100%) respectively compared with using plasma. The limit of detection for DBS is about 30 times higher than for plasma. ConclusionDBS use for SARS-CoV-2 serology, though feasible, is insensitive relative to immunoassays on plasma. Sample quality impacts on assay performance. Alternatives, including the collection of capillary blood samples, should be considered for screening programs.

10.
Preprint in English | medRxiv | ID: ppmedrxiv-20211763

ABSTRACT

Studies of adaptive immunity to SARS-CoV-2 include characterisation of lethal, severe and mild cases1-8. Understanding how long immunity lasts in people who have had mild or asymptomatic infection is crucial. Healthcare worker (HCW) cohorts exposed to and infected by SARS-CoV-2 during the early stages of the pandemic are an invaluable resource to study this question9-14. The UK COVIDsortium is a longitudinal, London hospital HCW cohort, followed from the time of UK lockdown9,10 ; weekly PCR, serology and symptom diaries allowed capture of asymptomatic infection around the time of onset, so duration of immunity could be tracked. Here, we conduct a cross-sectional, case-control, sub-study of 136 HCW at 16-18 weeks after UK lockdown, with 76 having had laboratory-confirmed SARS-CoV-2 mild or asymptomatic infection. Neutralising antibodies (nAb) were present in 90% of infected HCW sampled after the first wave; titres, likely to correlate with functional protection, were present in 66% at 16-18 weeks. T cell responses tended to be lower in asymptomatic infected HCW than those reporting case-definition symptoms of COVID-19, while nAb titres were maintained irrespective of symptoms. T cell and antibody responses were discordant. HCW lacking nAb also showed undetectable T cells to Spike protein but had T cells of other specificities. Our findings suggest that the majority of HCW with mild or asymptomatic SARS-CoV-2 infection carry nAb complemented by multi-specific T cell responses for at least 4 months after mild or asymptomatic SARS-CoV-2 infection.

SELECTION OF CITATIONS
SEARCH DETAIL
...