1.
Magn Reson Med ; 91(6): 2374-2390, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38225861

ABSTRACT

PURPOSE: To evaluate the performance of various MR electrical properties tomography (MR-EPT) methods at 3 T in terms of absolute quantification and spatial resolution limit for electrical conductivity. METHODS: Absolute quantification as well as spatial resolution performance were evaluated on homogeneous phantoms and a phantom with holes of different sizes, respectively. Ground-truth conductivities were measured with an open-ended coaxial probe connected to a vector network analyzer (VNA). Four widely used MR-EPT reconstruction methods were investigated: phase-based Helmholtz (PB), phase-based convection-reaction (PB-cr), image-based (IB), and generalized-image-based (GIB). These methods were compared using the same complex images from a 1 mm-isotropic UTE sequence. Alternative transceive phase acquisition sequences were also compared in PB and PB-cr. RESULTS: In large homogeneous phantoms, all methods showed a strong correlation with ground truth conductivities (r > 0.99); however, GIB was the best in terms of accuracy, spatial uniformity, and robustness to boundary artifacts. In the resolution phantom, the normalized root-mean-squared error of all methods grew rapidly (>0.40) when the hole size was below 10 mm, with simplified methods (PB and IB), or below 5 mm, with generalized methods (PB-cr and GIB). CONCLUSION: VNA measurements are essential to assess the accuracy of MR-EPT. In this study, all tested MR-EPT methods correlated strongly with the VNA measurements. The UTE sequence is recommended for MR-EPT, with the GIB method providing good accuracy for structures down to 5 mm. Structures below 5 mm may still be detected in the conductivity maps, but with significantly lower accuracy.


Subject(s)
Brain , Image Processing, Computer-Assisted , Image Processing, Computer-Assisted/methods , Algorithms , Magnetic Resonance Imaging/methods , Electric Conductivity , Phantoms, Imaging , Tomography/methods
2.
Eur Radiol ; 33(10): 6817-6827, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37188883

ABSTRACT

OBJECTIVES: To qualitatively and quantitatively compare a single breath-hold fast half-Fourier single-shot turbo spin echo sequence with deep learning reconstruction (DL HASTE) with T2-weighted BLADE sequence for liver MRI at 3 T. METHODS: From December 2020 to January 2021, patients with liver MRI were prospectively included. For qualitative analysis, sequence quality, presence of artifacts, conspicuity, and presumed nature of the smallest lesion were assessed using the chi-squared and McNemar tests. For quantitative analysis, number of liver lesions, size of the smallest lesion, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in both sequences were assessed using the paired Wilcoxon signed-rank test. Intraclass correlation coefficients (ICCs) and kappa coefficients were used to assess agreement between the two readers. RESULTS: One hundred and twelve patients were evaluated. Overall image quality (p = .006), artifacts (p < .001), and conspicuity of the smallest lesion (p = .001) were significantly better for the DL HASTE sequence than for the T2-weighted BLADE sequence. Significantly more liver lesions were detected with the DL HASTE sequence (356 lesions) than with the T2-weighted BLADE sequence (320 lesions; p < .001). CNR was significantly higher for the DL HASTE sequence (p < .001). SNR was higher for the T2-weighted BLADE sequence (p < .001). Interreader agreement was moderate to excellent depending on the sequence. Of the 41 supernumerary lesions visible only on the DL HASTE sequence, 38 (93%) were true-positives. CONCLUSION: The DL HASTE sequence can be used to improve image quality and contrast and reduces artifacts, allowing the detection of more liver lesions than with the T2-weighted BLADE sequence. CLINICAL RELEVANCE STATEMENT: The DL HASTE sequence is superior to the T2-weighted BLADE sequence for the detection of focal liver lesions and can be used in daily practice as a standard sequence. KEY POINTS: • The half-Fourier acquisition single-shot turbo spin echo sequence with deep learning reconstruction (DL HASTE sequence) has better overall image quality, reduced artifacts (particularly motion artifacts), and improved contrast, allowing the detection of more liver lesions than with the T2-weighted BLADE sequence. • The acquisition time of the DL HASTE sequence is at least eight times faster (21 s) than that of the T2-weighted BLADE sequence (3-5 min). • The DL HASTE sequence could replace the conventional T2-weighted BLADE sequence to meet the growing indication for hepatic MRI in clinical practice, given its diagnostic and time-saving performance.


Subject(s)
Deep Learning , Liver Neoplasms , Humans , Liver Neoplasms/diagnostic imaging , Prospective Studies , Magnetic Resonance Imaging/methods , Artifacts
3.
Eur Radiol ; 33(5): 3715-3725, 2023 May.
Article in English | MEDLINE | ID: mdl-36928567

ABSTRACT

OBJECTIVES: Acute ischemic stroke (AIS) is an emergency requiring both fast and informative MR sequences. We aimed to assess the performance of an artificial intelligence-enhanced ultrafast (UF) protocol, compared to the reference protocol, in the AIS management. METHODS: We included patients admitted in the emergency department for suspected AIS. Each patient underwent a 3-T MR protocol, including reference acquisitions of T2-FLAIR, DWI, and SWI (duration: 7 min 54 s) and their accelerated multishot EPI counterparts for T2-FLAIR and T2*, complemented by a single-shot EPI DWI (duration: 1 min 54 s). Two blinded neuroradiologists reviewed each dataset, assessing DWI (detection, location, number of acute lesions), FLAIR (vascular hyperintensities, visibility of acute lesions), and SWI/T2* (hemorrhagic transformation, thrombus). We compared the agreement between the diagnoses obtained with both protocols using kappa coefficients. RESULTS: A total of 173 patients were included consecutively, of whom 80 with an AIS in DWI. We found an almost perfect agreement between the UF and reference protocols regarding the detection, distribution, number of AIS in DWI (κ = 0.98, 0.98, and 0.87 respectively), the presence of vascular hyperintensities, and the presence of a parenchymal hyperintensity in the AIS region in FLAIR (κ = 0.93 and 0.89 respectively). Agreement was substantial in T2*/SWI for thrombus detection, and fair for hemorrhagic transformation detection (κ = 0.64 and 0.38 respectively). Differential diagnoses were similarly detected by both protocols (κ = 1). CONCLUSIONS: Our AI-enhanced ultrafast MRI protocol allowed an effective detection and characterization of both AIS and differential diagnoses in less than 2 min. KEY POINTS: • The AI-enhanced ultrafast MRI protocol allowed an effective detection of acute stroke. • Characterization of stroke features with the UF protocol was equivalent to the reference sequences. • Differential diagnoses were detected similarly by the UF and reference protocols.


Subject(s)
Deep Learning , Ischemic Stroke , Stroke , Humans , Echo-Planar Imaging/methods , Ischemic Stroke/diagnostic imaging , Artificial Intelligence , Magnetic Resonance Imaging/methods , Stroke/diagnosis , Diffusion Magnetic Resonance Imaging
4.
Phys Med Biol ; 68(8)2023 04 12.
Article in English | MEDLINE | ID: mdl-36791467

ABSTRACT

Objective.Laser interstitial thermal therapy (LITT) is a minimally invasive procedure used to treat a lesion through light irradiation and consequent temperature increase. Magnetic resonance thermometry imaging (MRTI) provides a multidimensional measurement of the temperature inside the target, thus enabling accurate monitoring of the damaged zone during the procedure. In proton resonance frequency shift-based thermometry, artifacts in the images may strongly interfere with the estimated temperature maps. In our work, after noticing the formation of the dipolar-behavior artifact linkable to magnetic susceptibility changes duringin vivoLITT, an investigation of susceptibility artifacts in tissue-mimicking phantoms was implemented.Approach.The artifact was characterized: (i) by measuring the area and total volume of error regions and their evolution during the treatment; and (ii) by comparison with temperature reference provided by three temperature sensing needles. Lastly, a strategy to avoid artifacts formation was devised by using the temperature-sensing needles to implement a temperature-controlled LITT.Main results.The artifact appearance was associated with gas bubble formation and with unwanted treatment effects producing magnetic susceptibility changes when 2 W laser power was set. The analysis of the artifact's dimension demonstrated that in the sagittal plane the dipolar-shape artifact may consistently spread following the temperature trend until reaching a volume 8 times bigger than the ablated one. Also, the artifact shape is quite symmetric with respect to the laser tip. An absolute temperature error showing a negative Gaussian profile in the area of susceptibility artifact with values up to 64.4 °C was estimated. Conversely, a maximum error of 2.8 °C is measured in the area not-affected by artifacts and far from the applicator tip. Finally, by regulating laser power, susceptibility artifacts formation was avoided, and appreciable thermal damage was induced.Significance.These findings may help in improving the MRTI-based guidance of thermal therapies.


Subject(s)
Artifacts , Thermometry , Temperature , Magnetic Resonance Imaging/methods , Thermometry/methods , Magnetic Resonance Spectroscopy
5.
MAGMA ; 36(5): 687-700, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36800143

ABSTRACT

OBJECTIVE: In the management of the aortic aneurysm, 4D flow magnetic resonance Imaging provides valuable information for the computation of new biomarkers using computational fluid dynamics (CFD). However, accurate segmentation of the aorta is required. Thus, our objective is to evaluate the performance of two automatic segmentation methods on the calculation of aortic wall pressure. METHODS: Automatic segmentation of the aorta was performed with methods based on deep learning and multi-atlas using the systolic phase in the 4D flow MRI magnitude image of 36 patients. Using mesh morphing, isotopological meshes were generated, and CFD was performed to calculate the aortic wall pressure. Node-to-node comparisons of the pressure results were made to identify the most robust automatic method respect to the pressures obtained with a manually segmented model. RESULTS: Deep learning approach presented the best segmentation performance with a mean Dice similarity coefficient and a mean Hausdorff distance (HD) equal to 0.92+/- 0.02 and 21.02+/- 24.20 mm, respectively. At the global level HD is affected by the performance in the abdominal aorta. Locally, this distance decreases to 9.41+/- 3.45 and 5.82+/- 6.23 for the ascending and descending thoracic aorta, respectively. Moreover, with respect to the pressures from the manual segmentations, the differences in the pressures computed from deep learning were lower than those computed from multi-atlas method. CONCLUSION: To reduce biases in the calculation of aortic wall pressure, accurate segmentation is needed, particularly in regions with high blood flow velocities. Thus, the deep learning segmen-tation method should be preferred.


Subject(s)
Deep Learning , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Aorta, Abdominal/diagnostic imaging , Blood Flow Velocity
6.
Magn Reson Imaging ; 99: 20-25, 2023 06.
Article in English | MEDLINE | ID: mdl-36621555

ABSTRACT

BACKGROUND: 4D flow MRI allows the analysis of hemodynamic changes in the aorta caused by pathologies such as thoracic aortic aneurysms (TAA). For personalized management of TAA, new biomarkers are required to analyze the effect of fluid structure iteration which can be obtained from 4D flow MRI. However, the generation of these biomarkers requires prior 4D segmentation of the aorta. OBJECTIVE: To develop an automatic deep learning model to segment the aorta in 4D from 4D flow MRI. METHODS: Segmentation is addressed with a U-Net based segmentation model that treats each 4D flow MRI frame as an independent sample. Performance is measured with respect to Dice score (DS) and Hausdorff distance (HD). In addition, the maximum and minimum surface areas at the level of the ascending aorta are measured and compared with those obtained from cine-MRI. RESULTS: The segmentation performance was 0.90 ± 0.02 for the DS and the mean HD was 9.58 ± 4.36 mm. A correlation coefficient of r = 0.85 was obtained for the maximum surface and r = 0.86 for the minimum surface between the 4D flow MRI and cine-MRI. CONCLUSION: The proposed automatic approach of 4D aortic segmentation from 4D flow MRI seems to be accurate enough to contribute to the wider use of this imaging technique in the analysis of pathologies such as TAA.


Subject(s)
Aortic Aneurysm, Thoracic , Deep Learning , Humans , Aorta, Thoracic , Magnetic Resonance Imaging/methods , Aorta , Magnetic Resonance Imaging, Cine/methods , Blood Flow Velocity
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 5008-5011, 2022 07.
Article in English | MEDLINE | ID: mdl-36085902

ABSTRACT

Magnetic Resonance Thermometry Imaging (MRTI) holds great potential in laser ablation (LA) monitoring. It provides the real-time multidimensional visualization of the treatment effect inside the body, thus enabling accurate intraoperative prediction of the thermal damage induced. Despite its great potential., thermal maps obtained with MRTI may be affected by numerous artifacts. Among the sources of error producing artifacts in the images., the cavitation phenomena which could occur in the tissue during LA induces dipole-structured artifacts. In this work., an analysis of the cavitation artifacts occurring during LA in a gelatin phantom in terms of symmetry in space and symmetry of temperature values was performed. Results of 2 Wand 4 W laser power were compared finding higher symmetry for the 2 W case in terms of both dimensions of artifact-lobes and difference in temperature values extracted in specular pixels in the image. This preliminary investigation of artifact features may provide a step forward in the identification of the best strategy to correct and avoid artifact occurrence during thermal therapy monitoring. Clinical Relevance- This work presents an analysis of cavitation artifacts in MRTI from LA which must be corrected to avoid error in the prediction of thermal damage during LA monitoring.


Subject(s)
Laser Therapy , Thermometry , Artifacts , Diagnostic Techniques, Cardiovascular , Magnetic Resonance Imaging
8.
Viruses ; 14(5)2022 05 01.
Article in English | MEDLINE | ID: mdl-35632691

ABSTRACT

BACKGROUND AND OBJECTIVES: Cerebral complications related to the COVID-19 were documented by brain MRIs during the acute phase. The purpose of the present study was to describe the evolution of these neuroimaging findings (MRI and FDG-PET/CT) and describe the neurocognitive outcomes of these patients. METHODS: During the first wave of the COVID-19 outbreak between 1 March and 31 May 2020, 112 consecutive COVID-19 patients with neurologic manifestations underwent a brain MRI at Strasbourg University hospitals. After recovery, during follow-up, of these 112 patients, 31 (initially hospitalized in intensive care units) underwent additional imaging studies (at least one brain MRI). RESULTS: Twenty-three men (74%) and eight women (26%) with a mean age of 61 years (range: 18-79) were included. Leptomeningeal enhancement, diffuse brain microhemorrhages, acute ischemic strokes, suspicion of cerebral vasculitis, and acute inflammatory demyelinating lesions were described on the initial brain MRIs. During follow-up, the evolution of the leptomeningeal enhancement was discordant, and the cerebral microhemorrhages were stable. We observed normalization of the vessel walls in all patients suspected of cerebral vasculitis. Four patients (13%) demonstrated new complications during follow-up (ischemic strokes, hypoglossal neuritis, marked increase in the white matter FLAIR hyperintensities with presumed vascular origin, and one suspected case of cerebral vasculitis). Concerning the grey matter volumetry, we observed a loss of volume of 3.2% during an average period of approximately five months. During follow-up, the more frequent FDG-PET/CT findings were hypometabolism in temporal and insular regions. CONCLUSION: A minority of initially severe COVID-19 patients demonstrated new complications on their brain MRIs during follow-up after recovery.


Subject(s)
COVID-19 , Vasculitis, Central Nervous System , COVID-19/diagnostic imaging , Female , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Neuroimaging , Positron Emission Tomography Computed Tomography
9.
Diagn Interv Imaging ; 103(10): 479-485, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35597761

ABSTRACT

PURPOSE: Acceleration of MRI acquisitions and especially of T2-weighted sequences is essential to reduce the duration of MRI examinations but also kinetic artifacts in liver imaging. The purpose of this study was to compare the acquisition time and the image quality of a single-shot fat-suppressed turbo spin-echo (TSE) T2-weighted sequence with deep learning reconstruction (HASTEDL) with that of a fat-suppressed T2-weighted BLADE TSE sequence in patients with focal liver lesions. MATERIALS AND METHODS: Ninety-five patients (52 men, 43 women; mean age: 61 ± 14 [SD]; age range: 28-87 years) with 42 focal liver lesions (17 hepatocellular carcinomas, 10 sarcoidosis lesions, 9 myeloma lesions, 3 liver metastases and 3 focal nodular hyperplasias) who underwent liver MRI at 1.5 T including HASTEDL and BLADE sequences were retrospectively included. Overall image quality, noise level in the liver, lesion conspicuity and sharpness of liver lesion contours were assessed by two independent readers. Liver signal-to-noise ratio (SNR) and lesion contrast-to-noise ratio (CNR) were measured and compared between the two sequences, as well as the mean duration of the sequences (Student t-test or Wilcoxon test for paired data). RESULTS: Median overall quality on HASTEDL images (3; IQR: 3, 3) was significantly greater than that on BLADE images (2; IQR: 1, 3) (P < 0.001). Median noise level in the liver on HASTEDL images (0; IQR: 0, 0.5) was significantly lower than that on BLADE images (1; IQR: 1, 2) (P < 0.001). On HASTEDL images, mean liver SNR (107.3 ± 39.7 [SD]) and mean focal liver lesion CNR (87.0 ± 76.6 [SD]) were significantly greater than those on BLADE images (67.1 ± 23.8 [SD], P < 0.001 and 48.6 ± 43.9 [SD], P = 0.027, respectively). Acquisition time was significantly shorter with the HASTEDL sequence (18 ± [0] s; range: 18-18 s) compared to BLADE sequence (152 ± 47 [SD] s; range: 87-263 s) (P < 0.001). CONCLUSION: By comparison with the BLADE sequence, HASTEDL sequence significantly reduces acquisition time while improving image quality, liver SNR and focal liver lesions CNR.


Subject(s)
Carcinoma, Hepatocellular , Deep Learning , Liver Neoplasms , Adult , Aged , Aged, 80 and over , Artifacts , Female , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Magnetic Resonance Imaging/methods , Male , Middle Aged , Retrospective Studies
10.
Invest Radiol ; 57(6): 412-421, 2022 06 01.
Article in English | MEDLINE | ID: mdl-34999669

ABSTRACT

OBJECTIVES: The aim of the study was to compare different magnetic resonance imaging (MRI) acquisition strategies appropriate for T2 quantification in the abdominal-pelvic area. The different techniques targeted in the study were chosen according to 2 main considerations: performing T2 measurement in an acceptable time for clinical use and preventing/correcting respiratory motion. MATERIALS AND METHODS: Acquisitions were performed at 3 T. To select sequences for in vivo measurements, a phantom experiment was conducted, for which the T2 values obtained with the different techniques of interest were compared with the criterion standard (single-echo SE sequence, multiple acquisitions with varying echo time). Repeatability and temporal reproducibility studies for the different techniques were also conducted on the phantom. Finally, an in vivo study was conducted on 12 volunteers to compare the techniques that offer acceptable acquisition time for clinical use and either address or correct respiratory motion. RESULTS: For the phantom study, the DESS and T2-preparation techniques presented the lowest precision (ρ2 = 0.9504 and ρ2 = 0.9849 respectively), and showed a poor repeatability/reproducibility compared with the other techniques. The strategy relying on SE-EPI showed the best precision and accuracy (ρ2 = 0.9994 and Cb = 0.9995). GRAPPATINI exhibited a very good precision (ρ2 = 0.9984). For the technique relying on radial TSE, the precision was not as good as GRAPPATINI (ρ2 = 0.9872). The in vivo study demonstrated good respiratory motion management for all of the selected techniques. It also showed that T2 estimate ranges were different from one method to another. For GRAPPATINI and radial TSE techniques, there were significant differences between all the different types of organs of interest. CONCLUSIONS: To perform T2 measurement in the abdominal-pelvic region, one should favor a technique with acceptable acquisition time for clinical use, with proper respiratory motion management, with good repeatability, reproducibility, and precision. In this study, the techniques relying respectively on SE-EPI, radial TSE, and GRAPPATINI appeared as good candidates.


Subject(s)
Magnetic Resonance Imaging , Pelvis , Humans , Magnetic Resonance Imaging/methods , Pelvis/diagnostic imaging , Phantoms, Imaging , Reproducibility of Results
11.
Dig Dis Sci ; 67(9): 4518-4524, 2022 09.
Article in English | MEDLINE | ID: mdl-34802092

ABSTRACT

BACKGROUND: Patients with Crohn's disease can develop intestinal strictures, containing various degrees of inflammation and fibrosis. Differentiation of the main component of a stricturing lesion is the key for defining the therapeutic management. AIMS: We assessed for the first time the accuracy of magnetic resonance elastography in detecting intestinal fibrosis and predicting clinical course in patients with Crohn's disease. METHODS: This was a prospective study of adult patients with Crohn's disease and magnetic resonance imaging examination, including magnetic resonance elastography, between April 2019 and February 2020. The association between the bowel stiffness value and the degree of fibrosis was evaluated. The relationship between the stiffness value and the occurrence of clinical events was also investigated. RESULTS: A total of 69 patients were included. The stiffness value measured by magnetic resonance elastography was correlated with the degree of fibrosis (p < 0.001). A bowel stiffness ≥ 3.57 kPa predicted the occurrence of clinical events with an area under the curve of 0.82 (95% CI 0.71-0.93). Bowel stiffness ≥ 3.57 kPa was associated with an increased risk of clinical events (p < 0.0001). CONCLUSION: In Crohn's disease, magnetic resonance elastography is a reliable tool for detecting intestinal fibrosis and predicting a worse disease outcome.


Subject(s)
Crohn Disease , Elasticity Imaging Techniques , Adult , Crohn Disease/complications , Crohn Disease/diagnostic imaging , Crohn Disease/pathology , Elasticity Imaging Techniques/methods , Fibrosis , Humans , Magnetic Resonance Imaging/methods , Pilot Projects , Prospective Studies
12.
Diagnostics (Basel) ; 11(10)2021 Oct 13.
Article in English | MEDLINE | ID: mdl-34679584

ABSTRACT

To compare two magnetic resonance cholangiopancreatography (MRCP) sequences at 3 Tesla (3T): the conventional 3D Respiratory-Triggered SPACE sequence (RT-MRCP) and a prototype 3D Compressed-Sensing Breath-Hold SPACE sequence (CS-BH-MRCP), in terms of qualitative and quantitative image quality and radiologist's diagnostic confidence for detecting common bile duct (CBD) lithiasis, biliary anastomosis stenosis in liver-transplant recipients, and communication of pancreatic cyst with the main pancreatic duct (MPD). Sixty-eight patients with suspicion of choledocholithiasis or biliary anastomosis stenosis after liver transplant, or branch-duct intraductal papillary mucinous neoplasm of the pancreas (BD-IPMN), were included. The relative CBD to peri-biliary tissues (PBT) contrast ratio (CR) was assessed. Overall image quality, presence of artefacts, background noise suppression and the visualization of 12 separated segments of the pancreatic and bile ducts were evaluated by two observers working independently on a five-point scale. Diagnostic confidence was scored on a 1-3 scale. The CS-BH-MRCP presented significantly better CRs (p < 0.0001), image quality (p = 0.004), background noise suppression (p = 0.011), fewer artefacts (p = 0.004) and better visualization of pancreatic and bile ducts segments with the exception of the proximal CBD (p = 0.054), cystic duct confluence (p = 0.459), the four secondary intrahepatic bile ducts, and central part of the MPD (p = 0.885) for which no significant differences were found. Overall, diagnostic confidence was significantly better with the CS-BH-MRCP sequence for both readers (p = 0.038 and p = 0.038, respectively). This study shows that the CS-BH-MRCP sequence presents overall better image quality and bile and pancreatic ducts visualization compared to the conventional RT-MRCP sequence at 3T.

13.
Eur J Radiol ; 142: 109873, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34371309

ABSTRACT

PURPOSE: To evaluate the image quality of an accelerated compressed-sensing single-breath-hold 3D magnetic resonance cholangiopancreatography (BH-CS-MRCP) prototype sequence compared to the standard 3D sequence with respiratory triggering (STD-MRCP) at 1.5 T and 3 T. To assess the individual factors that can affect image quality. METHOD: This is a retrospective analysis. Both sequences (BH-CS-MRCP and STD-MRCP) were performed in 200 patients at 1.5 T and 200 patients at 3 T. Overall image quality and the visualization of the bilio-pancreatic ducts were rated on a 5-point scale. Image sharpness and background suppression were rated on a 4-point scale. A double reading was performed in 50 patients to assess the inter-observer reproducibility. Individual characteristics studied were gender, age, BMI, ascites, abdominal surface and breath-hold quality. RESULTS: At 1.5 T, BH-CS-MRCP was inferior to STD-MRCP in terms of overall quality (p = 0.0046), background suppression (p < 0.0001), visualization of the cystic duct (p < 0.0001), the right bile duct (p = 0.0008), the left bile duct (p = 0.0152), and the main pancreatic duct (p < 0.0001). However, BH-CS-MRCP was sharper than STD-MRCP (p = 0.028). At 3 T, BH-CS-MRCP was superior to STD-MRCP for overall quality (p < 0.0001), sharpness (p < 0.0001), and visualization of the bilio-pancreatic ducts (p < 0.0001). Background signal was conversely better suppressed in STD-MRCP (p < 0.0001). At 1.5 T, the volume of ascites was inversely correlated with image quality for BH-CS-MRCP while BMI was inversely correlated with image quality for STD-MRCP. Breath-hold quality was correlated with image quality for BH-CS-MRCP at 1.5 T and 3 T. CONCLUSION: BH-CS-MRCP is feasible in clinical routine at 1.5 and 3 T, yielding significantly better perceived image quality at 3 T but not at 1.5 T. BH-CS-MRCP appears to be influenced by ascites whereas STD-MRCP is influenced by BMI at 1.5 T. This study was approved by the Ethics Review Board for Research in Medical Imaging (IRB: CRM-2003-065).


Subject(s)
Pancreatic Diseases , Cholangiopancreatography, Magnetic Resonance , Humans , Imaging, Three-Dimensional , Pancreatic Diseases/diagnostic imaging , Reproducibility of Results , Retrospective Studies
14.
Eur Radiol ; 31(12): 9556-9566, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34117556

ABSTRACT

OBJECTIVES: We evaluated the relationship between the maximum slope (MS) based on ultrafast breast DCE-MRI sequences, and the clinical parameters and routine prognostic factors of breast cancer. METHODS: 210 lesions were retrospectively evaluated: 150 malignant (30 each of luminal A invasive carcinoma, luminal B invasive carcinoma, HER2 overexpression (HER2), triple negative (TN), invasive lobular carcinoma (ILC)), and 60 benign. For each lesion, the MS was obtained with an ultrafast sequence and semi-quantitative curves were classified into three types with a conventional DCE sequence. The correlation between MS and age, body mass index (BMI), menopause, and routine prognostic factors were analyzed. RESULTS: A MS cut-off at 6.5%/s could discriminate benign from malignant lesions, with sensitivity and specificity of 84% and 90%, respectively, whereas analysis of semi-quantitative curves showed sensitivity and specificity of 89.3% and 55%, respectively. In multivariate analysis, MS values decreased with BMI increasing (p = 0.035), postmenopausal status (p < 0.001), and positive ER status (p < 0.001) and increased with tumor size (p < 0.001). The MS was significantly lower for the pooled luminal A + ILC group than for the pooled luminal B + HER2 + TN group featuring tumors with poorer prognoses (p < 0.001). With a threshold of 11%/s, the sensitivity and specificity to identify invasive carcinoma subtypes with poorer prognoses were 71% and 68%, respectively. CONCLUSION: The MS allows better tumor characterization and identifies factors of poor prognosis for breast cancer. KEY POINTS: • Maximum slope calculated from ultrafast breast DCE-MRI differentiates benign from malignant breast lesions better than semi-quantitative curves of conventional DCE-MRI. • Maximum slope calculated from ultrafast breast DCE-MRI identifies breast cancers with poor prognoses. • In the case of multiple lesions, the most aggressive may be identified and targeted by measuring the maximum slope.


Subject(s)
Breast Neoplasms , Contrast Media , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Female , Humans , Magnetic Resonance Imaging , Retrospective Studies
15.
J Vasc Surg ; 74(3): 910-920.e1, 2021 09.
Article in English | MEDLINE | ID: mdl-33812036

ABSTRACT

BACKGROUND: Carotid stenosis can profoundly affect cerebral hemodynamics, which cannot simply be inferred from the degree of stenosis. We quantified and mapped the distribution of the blood flow rate (BFR) in the cerebral arteries before and after carotid endarterectomy using four-dimensional (4D) phase-contrast (PC) magnetic resonance imaging (MRI). METHODS: Nineteen patients (age, 71 ± 6 years; 2 women) with symptomatic carotid stenosis (≥50%) undergoing carotid endarterectomy (CEA) were investigated using 4D PC-MRI before and after surgery. The BFR was measured in 17 cerebral arteries and the ophthalmic arteries. Collateral recruitment through the anterior and posterior communicating arteries, ophthalmic arteries, and leptomeningeal arteries was quantified. BFR laterality was significantly different between the paired contralateral and ipsilateral arteries. Subgroups were defined according to the presence of collateral recruitment. RESULTS: The total cerebral blood flow had increased by 15% (P < .01) after CEA. Before CEA, laterality was seen in the internal carotid artery, anterior cerebral artery, and middle cerebral artery (MCA). On the ipsilateral side, an increased BFR was found after CEA in the internal carotid artery (246 ± 62 mL/min vs 135 ± 80 mL/min; P < .001), anterior cerebral artery (87 ± mL/min vs 38 ± 58 mL/min; P < .01), and MCA (149 ± 43 mL/min vs 119 ± 34 mL/min; P < .01), resulting in a postoperative BFR distribution without signs of laterality. In the nine patients with preoperatively recruited collaterals, BFR laterality was found in the MCA before, but not after, CEA (P < .01). This laterality was not found in the 10 patients without collateral recruitment (P = .2). The degree of stenosis did not differ between the groups with and without collateral recruitment (P = .85). CONCLUSIONS: Using 4D PC-MRI, we have presented a comprehensive and noninvasive method to evaluate the cerebral hemodynamics due to carotid stenosis before and after CEA. MCA laterality, seen in the patients with collateral recruitment before CEA, pointed toward a hemodynamic disturbance in MCA territory for those patients. This methodologic advancement provides an insight into the pathophysiology of cerebral hemodynamics in patients with carotid stenosis.


Subject(s)
Carotid Stenosis/surgery , Cerebrovascular Circulation , Endarterectomy, Carotid , Magnetic Resonance Imaging , Middle Cerebral Artery/diagnostic imaging , Perfusion Imaging , Aged , Blood Flow Velocity , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/physiopathology , Collateral Circulation , Endarterectomy, Carotid/adverse effects , Female , Humans , Male , Middle Aged , Middle Cerebral Artery/physiopathology , Predictive Value of Tests , Prospective Studies , Severity of Illness Index , Treatment Outcome
16.
NMR Biomed ; 34(6): e4498, 2021 06.
Article in English | MEDLINE | ID: mdl-33634498

ABSTRACT

Hepatic fibrosis causes an increase in liver stiffness, a parameter measured by elastography and widely used as a diagnosis method. The concomitant presence of portal vein thrombosis (PVT) implies a change in hepatic portal inflow that could also affect liver elasticity. The main objective of this study is to determine the extent to which the presence of portal occlusion can affect the mechanical properties of the liver and potentially lead to misdiagnosis of fibrosis and hepatic cirrhosis by elastography. Portal vein occlusion was generated by insertion and inflation of a balloon catheter in the portal vein of four swines. The portal flow parameters peak flow (PF) and peak velocity magnitude (PVM) and liver mechanical properties (shear modulus) were then investigated using 4D-flow MRI and MR elastography, respectively, for progressive obstructions of the portal vein. Experimental results indicate that the reduction of the intrahepatic venous blood flow (PF/PVM decreases of 29.3%/8.5%, 51.0%/32.3% and 83.3%/53.6%, respectively) measured with 50%, 80% and 100% obstruction of the portal vein section results in a decrease of liver stiffness by 0.8% ± 0.1%, 7.7% ± 0.4% and 12.3% ± 0.9%, respectively. While this vascular mechanism does not have sufficient influence on the elasticity of the liver to modify the diagnosis of severe fibrosis or cirrhosis (F4 METAVIR grade), it may be sufficient to attenuate the increase in stiffness due to moderate fibrosis (F2-F3 METAVIR grades) and consequently lead to false-negative diagnoses with elastography in the presence of PVT.


Subject(s)
Elasticity , Hepatic Veno-Occlusive Disease/physiopathology , Liver/physiopathology , Portal Vein/physiopathology , Regional Blood Flow/physiology , Animals , Biomechanical Phenomena , Disease Models, Animal , Female , Magnetic Resonance Imaging , Swine
17.
Magn Reson Med ; 85(2): 762-776, 2021 02.
Article in English | MEDLINE | ID: mdl-32783236

ABSTRACT

PURPOSE: To develop a fast and easy-to-use electrical properties tomography (EPT) method based on a single MR scan, avoiding both the need of a B1 -map and transceive phase assumption, and that is robust against noise. THEORY: Derived from Maxwell's equations, conductivity, and permittivity are reconstructed from a new partial differential equation involving the product of the RF fields and its derivatives. This also allows us to clarify and revisit the relevance of common assumptions of MREPT. METHODS: Our new governing equation is solved using a 3D finite-difference scheme and compared to previous frameworks. The benefits of our method over selected existing MREPT methods are demonstrated for different simulation models, as well as for both an inhomogeneous agar phantom gel and in vivo brain data at 3T. RESULTS: Simulation and experimental results are illustrated to highlight the merits of the proposed method over existing methods. We show the validity of our algorithm in versatile configurations, with many transition regions notably. Complex admittivity maps are also provided as a complementary MR contrast. CONCLUSION: Because it avoids time-consuming RF field mapping and generalizes the use of standard MR image for electrical properties reconstruction, this contribution is promising as a new step forward for clinical applications.


Subject(s)
Magnetic Resonance Imaging , Tomography , Algorithms , Electric Conductivity , Image Processing, Computer-Assisted , Phantoms, Imaging
18.
Acta Ophthalmol ; 99(5): e679-e685, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33210819

ABSTRACT

PURPOSE: To examine feasibility of phase-contrast magnetic resonance imaging (PCMRI) and to assess blood flow rate in the ophthalmic artery (OA) in patients with normal tension glaucoma (NTG) compared with healthy controls. METHODS: Sixteen patients with treated NTG and 16 age- and sex-matched healthy controls underwent PCMRI using a 3-Tesla scanner and ophthalmological examinations. OA blood flow rate was measured using a 2D PCMRI sequence with a spatial resolution of 0.35 mm2 . RESULTS: The blood flow rate in the NTG group was 9.6 ± 3.9 ml/min [mean ± SD] compared with 11.9 ± 4.8 ml/min in the control group. Resistance Index (RI) and Pulsatility Index (PI) were 0.73 ± 0.08 and 1.36 ± 0.29, respectively, in the NTG group and 0.68 ± 0.13 and 1.22 ± 0.40, respectively, in the healthy group. The mean visual field index (VFI) was 46% ± 25 for the worse NTG eyes. The measured differences observed between the NTG group and the control group in blood flow rate (p = 0.12), RI (p = 0.18) and PI (p = 0.27) were non-significant. CONCLUSIONS: This case-control study, using PCMRI, showed a slight, but non-significant, reduction in OA blood flow rate in the NTG patients compared with the healthy controls. These results indicate that blood flow may be of importance in the pathogenesis of NTG. Considering that only a limited portion of the total OA blood flow supplies the ocular system and the large inter-individual differences, a larger study or more advanced PCMRI technique might give the answer.


Subject(s)
Blood Flow Velocity/physiology , Intraocular Pressure/physiology , Low Tension Glaucoma/physiopathology , Magnetic Resonance Imaging/methods , Ophthalmic Artery/diagnostic imaging , Aged , Feasibility Studies , Female , Humans , Low Tension Glaucoma/diagnosis , Male , Ophthalmic Artery/physiopathology , Prospective Studies , ROC Curve , Ultrasonography, Doppler, Color
19.
Invest Ophthalmol Vis Sci ; 61(12): 17, 2020 10 01.
Article in English | MEDLINE | ID: mdl-33074299

ABSTRACT

Purpose: To investigate if decrease of IOP affects the volumetric blood flow rate in the ophthalmic artery (OA) in patients with previously untreated ocular hypertension. Methods: Subjects with untreated ocular hypertension (n = 30; mean age 67 ± 8 years; 14 females) underwent ophthalmologic examination and a 3-Tesla magnetic resonance imaging investigation. The magnetic resonance imaging included three-dimensional high-resolution phase-contrast magnetic resonance imaging to measure the OA blood flow rate. The subjects received latanoprost once daily in the eye with higher pressure, the untreated eye served as control. The same measurements were repeated approximately 1 week later. Results: The mean OA blood flow rate before and after treatment was 12.4 ± 4.4 and 12.4 ± 4.6 mL/min in the treated eye (mean ± SD; P = 0.92) and 13.5 ± 5.2 and 13.4 ± 4.1 mL/min in the control eye (P = 0.92). There was no significant difference between the treated and control eye regarding blood flow rate before (P = 0.13) or after treatment (P = 0.18), or change in blood flow rate after treatment (0.1 ± 3.1 vs. -0.1 ± 4.0 mL/min, P = 0.84). Latanoprost decreased the IOP by 7.2 ± 3.1 mm Hg in the treated eye (P < 0.01). Conclusions: The results indicate that a significant lowering of IOP does not affect the blood flow rate of the OA in ocular hypertension subjects. The ability to maintain blood supply to the eye independent of the IOP could be a protective mechanism in preserving vision in subjects with ocular hypertension.


Subject(s)
Intraocular Pressure/physiology , Ocular Hypertension/physiopathology , Ophthalmic Artery/physiopathology , Aged , Antihypertensive Agents/therapeutic use , Blood Flow Velocity/physiology , Blood Pressure/physiology , Female , Humans , Latanoprost/therapeutic use , Magnetic Resonance Imaging , Male , Middle Aged , Ocular Hypertension/drug therapy , Prospective Studies , Regional Blood Flow/physiology , Tonometry, Ocular
20.
Stroke ; 50(5): 1081-1088, 2019 05.
Article in English | MEDLINE | ID: mdl-30943887

ABSTRACT

Background and Purpose- Four-dimensional phase-contrast magnetic resonance imaging enables quantification of blood flow rate (BFR; mL/min) in multiple cerebral arteries simultaneously, making it a promising technique for hemodynamic investigation in patients with stroke. The aim of this study was to quantify the hemodynamic disturbance and the compensatory pattern of collateral flow in patients with symptomatic carotid stenosis. Methods- Thirty-eight patients (mean, 72 years; 27 men) with symptomatic carotid stenosis (≥50%) or occlusion were investigated using 4-dimensional phase-contrast magnetic resonance imaging. For each patient, BFR was measured in 19 arteries/locations. The ipsilateral side to the symptomatic carotid stenosis was compared with the contralateral side. Results- Internal carotid artery BFR was lower on the ipsilateral side (134±87 versus 261±95 mL/min; P<0.001). BFR in anterior cerebral artery (A1 segment) was lower on ipsilateral side (35±58 versus 119±72 mL/min; P<0.001). Anterior cerebral artery territory bilaterally was primarily supplied by contralateral internal carotid artery. The ipsilateral internal carotid artery mainly supplied the ipsilateral middle cerebral artery (MCA) territory. MCA was also supplied by a reversed BFR found in the ophthalmic and the posterior communicating artery routes on the ipsilateral side (-5±28 versus 10±28 mL/min, P=0.001, and -2±12 versus 6±6 mL/min, P=0.03, respectively). Despite these compensations, BFR in MCA was lower on the ipsilateral side, and this laterality was more pronounced in patients with severe carotid stenosis (≥70%). Although comparing ipsilateral MCA BFR between stenosis groups (<70% and ≥70%), there was no difference ( P=0.95). Conclusions- With a novel approach using 4-dimensional phase-contrast magnetic resonance imaging, we could simultaneously quantify and rank the importance of collateral routes in patients with carotid stenosis. An important observation was that contralateral internal carotid artery mainly secured the bilateral anterior cerebral artery territory. Because of the collateral recruitment, compromised BFR in MCA is not necessarily related to the degree of carotid stenosis. These findings highlight the importance of simultaneous investigation of the hemodynamics of the entire cerebral arterial tree.


Subject(s)
Blood Flow Velocity/physiology , Carotid Stenosis/diagnostic imaging , Cerebrovascular Circulation/physiology , Collateral Circulation/physiology , Aged , Aged, 80 and over , Carotid Stenosis/physiopathology , Female , Humans , Male , Middle Aged , Ultrasonography, Doppler, Transcranial/methods