Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Cancer Res Commun ; 3(12): 2483-2496, 2023 12 07.
Article in English | MEDLINE | ID: mdl-38009896

ABSTRACT

Medulloblastoma is one of the most prevalent solid tumors found in children, occurring in the brain's posterior fossa. The standard treatment protocol involves maximal resection surgery followed by craniospinal irradiation and chemotherapy. Despite a long-term survival rate of 70%, wide disparities among patients have been observed. The identification of pertinent targets for both initial and recurrent medulloblastoma cases is imperative. Both primary and recurrent medulloblastoma are marked by their aggressive infiltration into surrounding brain tissue, robust angiogenesis, and resistance to radiotherapy. While the significant role of integrin-αvß3 in driving these characteristics has been extensively documented in glioblastoma, its impact in the context of medulloblastoma remains largely unexplored. Integrin-αvß3 was found to be expressed in a subset of patients with medulloblastoma. We investigated the role of integrin-αvß3 using medulloblastoma-derived cell lines with ß3-subunit depletion or overexpression both in vitro and in vivo settings. By generating radioresistant medulloblastoma cell lines, we uncovered an increased integrin-αvß3 expression, which correlated with increased susceptibility to pharmacologic integrin-αvß3 inhibition with cilengitide, a competitive ligand mimetic. Finally, we conducted single-photon emission computed tomography (SPECT)/MRI studies on orthotopic models using a radiolabeled integrin-αvß3 ligand (99mTc-RAFT-RGD). This innovative approach presents the potential for a novel predictive imaging technique in the realm of medulloblastoma. Altogether, our findings lay the foundation for employing SPECT/MRI to identify a specific subset of patients with medulloblastoma eligible for integrin-αvß3-directed therapies. This breakthrough offers a pathway toward more targeted and effective interventions in the treatment of medulloblastoma. SIGNIFICANCE: This study demonstrates integrin-αvß3's fundamental role in medulloblastoma tumorigenicity and radioresistance and the effect of its expression on cilengitide functional activity.


Subject(s)
Brain Neoplasms , Cerebellar Neoplasms , Medulloblastoma , Child , Humans , Brain Neoplasms/drug therapy , Cerebellar Neoplasms/drug therapy , Integrin alphaVbeta3/genetics , Ligands , Medulloblastoma/drug therapy , Tomography, Emission-Computed, Single-Photon/methods
2.
EJNMMI Phys ; 10(1): 45, 2023 Jul 31.
Article in English | MEDLINE | ID: mdl-37522931

ABSTRACT

PURPOSE: The main objective of this study was to evaluate the ability of a large field Cadmium Zinc Telluride (CZT) camera to estimate thyroid uptake (TU) on single photon emission computed tomography (SPECT) images with and without attenuation correction (Tomo-AC and Tomo-NoAC) compared with Planar acquisition in a series of 23 consecutive patients. The secondary objective was to determine radiation doses for the tracer administration and for the additional Computed Tomography (CT) scan. METHODS: Cross-calibration factors were determined using a thyroid phantom, for Planar, Tomo-AC and Tomo-NoAC images. Then Planar and SPECT/CT acquisitions centered on the thyroid were performed on 5 anthropomorphic phantoms with activity ranging from 0.4 to 10 MBq, and 23 patients after administration of 79.2 ± 3.7 MBq of [99mTc]-pertechnetate. We estimated the absolute thyroid activity (AThA) for the anthropomorphic phantoms and the TU for the patients. Radiation dose was also determined using International Commission on Radiological Protection (ICRP) reports and VirtualDoseTMCT software. RESULTS: Cross-calibration factors were 66.2 ± 4.9, 60.7 ± 0.7 and 26.5 ± 0.3 counts/(MBq s), respectively, for Planar, Tomo-AC and Tomo-NoAC images. Theoretical and estimated AThA for Planar, Tomo-AC and Tomo-NoAC images were statistically highly correlated (r < 0.99; P < 10-4) and the average of the relative percentage difference between theoretical and estimated AThA were (8.6 ± 17.8), (- 1.3 ± 5.2) and (12.8 ± 5.7) %, respectively. Comparisons between TU based on different pairs of images (Planar vs Tomo-AC, Planar vs Tomo-NoAC and Tomo-AC vs Tomo-NoAC) showed statistically significant correlation (r = 0.972, 0.961 and 0.935, respectively; P < 10-3). Effective and thyroid absorbed doses were, respectively (0.34CT + 0.95NM) mSv, and (3.88CT + 1.74NM) mGy. CONCLUSION: AThA estimation using Planar and SPECT/CT acquisitions on a new generation of CZT large-field cameras is feasible. In addition, TU on SPECT/CT was as accurate as conventional planar acquisition, but the CT induced additional thyroid exposure. Trial registration Name of the registry: Thyroid Uptake Quantification on a New Generation of Gamma Camera (QUANTHYC). TRIAL NUMBER: NCT05049551. Registered September 20, 2021-Retrospectively registered, https://clinicaltrials.gov/ct2/show/record/NCT05049551?cntry=MC&draw=2&rank=4 .

3.
J Headache Pain ; 24(1): 51, 2023 May 11.
Article in English | MEDLINE | ID: mdl-37170187

ABSTRACT

BACKGROUND: This study compares the outcome of patients suffering from medically refractory classical trigeminal neuralgia (TN) after treatment with radiosurgery using two different shot sizes (5- and 6-mm). METHODS: All patients included in this open, prospective, non-controlled study were treated in a single institution for TN (95 cases in 93 patients) with LINear ACcelerators (LINAC) single-dose radiosurgery using a 5-mm shot (43 cases) or 6-mm shot (52 cases). The target was positioned on the intracisternal part of the trigeminal nerve. RESULTS: The mean Dmax (D0.035) to the brainstem was higher in the 6-mm group: 12.6 vs 21.3 Gy (p < 0.001). Pain relief was significantly better in the 6-mm group: at 12 and 24 months in the 6-mm group the rate of pain-free patients was 90.2 and 87.8%, respectively vs. 73.6 and 73.6% in the 5-mm group (p = 0.045). At 12 and 24 months post-radiosurgical hypoesthesia was more frequent in the 6-mm group: 47.0 and 58% vs.11.3 and 30.8% in the 5-mm group (p = 0.002). To investigate the effect of cone diameter and the dose to the brainstem on outcomes, patients were stratified into three groups: group 1 = 5-mm shot, (all Dmax < 25 Gy, 43 cases), group 2 = 6-mm shot, Dmax < 25 Gy (32 cases), group 3 = 6-mm shot Dmax > 25 Gy (20 cases). At 12 months the rates of hypoesthesia were 11.3, 33.5 and 76.0%, respectively in groups 1, 2 and 3 (p < 0.001) and the rates of recurrence of pain were 26.4, 16.5 and 5%, respectively, (p = 0.11). CONCLUSION: LINAC treatment with a 6-mm shot provided excellent control of pain, but increased the rate of trigeminal nerve dysfunction, especially when the maximum dose to the brainstem was higher than 25 Gy.


Subject(s)
Radiosurgery , Trigeminal Neuralgia , Humans , Trigeminal Neuralgia/radiotherapy , Trigeminal Neuralgia/surgery , Trigeminal Neuralgia/etiology , Prospective Studies , Treatment Outcome , Hypesthesia/etiology , Hypesthesia/surgery , Pain , Retrospective Studies , Follow-Up Studies
4.
Biochem Biophys Rep ; 27: 101098, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34430714

ABSTRACT

The chemokine receptors CXCR1/2 play a key role in the aggressiveness of several types of cancers including head and neck squamous cell carcinomas (HNSCCs). In HNSCCs, CXCR1/2 signaling promotes cell proliferation and angiogenesis leading to tumor growth and metastasis. The competitive inhibitor of CXCR1/2, C29, inhibits the growth of experimental HNSCCs in mice. However, a non-invasive tool to monitor treatment response is essential to implement the use of C29 in clinical practices. 18F-FDG PET/CT is a gold-standard tool for the staging and the post-therapy follow-up of HNSCCs patients. Our study aimed to perform the first in vivo monitoring of C29 efficacy by non-invasive 18F-FDG PET/CT imaging. Mice bearing experimental HNSCCs (CAL33) were injected with 18F-FDG (T0) and thereafter treated (n = 7 mice, 9 tumors, 50 mg/kg by gavage) or not (n = 7 mice, 10 tumors) with C29 for 4 consecutive days. Final 18F-FDG-tumor uptake was determined at day 4 (TF). The average relative change (TF-T0) in 18F-FDG tumor uptake was +25.85 ± 10.93 % in the control group vs -5.72 ± 10.07 % in the C29-treated group (p < 0.01). These results were consistent with the decrease of the tumor burden and with the decrease of tumor proliferating Ki67+ cells. These results paved the way for the use of 18F-FDG to monitor tumor response following C29 treatment.

5.
J Appl Clin Med Phys ; 19(6): 88-98, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30216702

ABSTRACT

The purpose of this work is to assess eight detectors performance for output factor (OF), percent depth dose (PDD), and beam profiles in a 6-MV Clinac stereotactic radiosurgery mode for cone irradiation using Monte Carlo simulation as reference. Cones with diameters comprised between 30 and 4 mm have been studied. The evaluated detectors were ionization chambers: pinpoint and pinpoint 3D, diodes: SRS, P and E, Edge, MicroDiamond and EBT3 radiochromic films. The results showed that pinpoints underestimate OF up to -2.3% for cone diameters ≥10 mm and down to -12% for smaller cones. Both nonshielded (SRS and E) and shielded diodes (P and Edge) overestimate the OF respectively up to 3.3% and 5.2% for cone diameters ≥10 mm and in both cases more than 7% for smaller cones. MicroDiamond slightly overestimates the OF, 3.7% for all the cones and EBT3 film is the closest to Monte Carlo with maximum difference of ±1% whatever the cone size is. For the profiles and the PDD, particularly for the small cones, the size of the detector predominates. All diodes and EBT3 agree with the simulation within ±0.2 mm for beam profiles determination. For PDD curve all the active detectors response agree with simulation up to 1% for all the cones. EBT3 is the more accurate detector for beam profiles and OF determinations of stereotactic cones but it is restrictive to use. Due to respectively inappropriate size of the sensitive volume and composition, pinpoints and diodes do not seem appropriate without OF corrective factors below 10 mm diameter cone. MicroDiamond appears to be the best detector for OF determination regardless all cones. For off-axis measurements, the size of the detector predominates and for PDD all detectors give promising results.


Subject(s)
Monte Carlo Method , Neoplasms/surgery , Particle Accelerators/instrumentation , Phantoms, Imaging , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Computer Simulation , Humans , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...