Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Cardiol ; 123(11): 1765-1771, 2019 06 01.
Article in English | MEDLINE | ID: mdl-30926144

ABSTRACT

PROMUS Element (PE) Plus post-approval study was a large prospective, observational, all-comers study designed to evaluate the safety and performance of a thin-strut platinum chromium everolimus-eluting PE Plus stent in everyday clinical practice. A total of 2,683 "real-world" patients with limited clinical or anatomic exclusion criteria were enrolled at 52 clinical sites in the United States. The study met its primary end point of 12-month cardiac death or myocardial infarction (CD/MI) compared with a prespecified performance goal (p <0.0001). Five-year clinical outcomes were evaluated in overall PE Plus post-approval study patients and high-risk subgroups. During the 5-year follow-up period, CD/MI and stent thrombosis related to the PE Plus stent occurred in 9% and 2.2% overall patients, respectively. The reported all-cause mortality rate was 15%, with 7% classified as cardiac-related. A total of 18% patients underwent target vessel revascularization, and 11% were reported as target lesion revascularization. The rates of PE Plus stent-related CD/MI remained low in patients with medically treated diabetes (13%), small vessels (9%), and long stents (10%). PE Plus stent-related thrombosis through 5 years in patients with diabetes, small vessels and long stents was 4.2%, 2.2%, and 2.6%, respectively. The occurrence of target lesion revascularization was numerically higher in patients with diabetes (16%) and long lesions (18%) than the small vessels subgroup (11%). In conclusion, the final 5-year results establish the long-term safety and efficacy of the PE Plus stent in a broad, unselected patient population representative of "real-world" clinical practice.


Subject(s)
Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Chromium , Combined Modality Therapy , Female , Humans , Male , Platinum , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome , United States
2.
Am J Cardiol ; 117(4): 539-545, 2016 Feb 15.
Article in English | MEDLINE | ID: mdl-26732420

ABSTRACT

The PROMUS Element Plus US Post-Approval Study (PE-Plus PAS) was a prospective, open-label, multicenter, observational study designed to examine outcomes in everyday clinical practice in patients treated with everolimus-eluting, platinum-chromium PROMUS Element Plus stents at 52 centers in the United States. This is the first report of results from this large study. The primary end point of the PE-Plus PAS was 12-month cardiac death or myocardial infarction in the more restricted population of "PLATINUM-like" patients pooled from the PE-Plus PAS, PE-PROVE (PROMUS Element European post-approval study), and PLATINUM Workhorse/Small Vessel trials. Additional clinical end points were tested in the overall PE-Plus PAS patient population. Of the 2,683 patients enrolled in PE-Plus PAS, 70% were men, mean age was 64 years, 33% had diabetes, and 29% were "PLATINUM-like." Among the PLATINUM-like patients, 12-month cardiac death or myocardial infarction was 1.8% (33 of 1,855) with an upper 1-sided 95% confidence interval of 2.3%, which was significantly less than the prespecified performance goal of 3.2% (pnoninferiority <0.001). In the overall PE-Plus population, 12-month target vessel failure (defined as death, MI, or revascularization related to the target vessel) was 6.7% (170 of 2,554), cardiac death was 1.4% (37 of 2,554), MI was 1.1% (28 of 2,554), and ARC-definite/probable stent thrombosis was 0.7% (19 of 2,554). A prespecified secondary end point of 12-month target vessel failure in diabetic patients demonstrated a rate of 4.2% (14 of 332) with an upper 1-sided 95% confidence interval of 6.03%, which was significantly less than the performance goal of 12.6% (pnoninferiority <0.001). In conclusion, in this large registry of unselected patients, coronary artery revascularization with the PROMUS Element Plus everolimus-eluting stent demonstrates favorable results with low 1-year clinical event rates.


Subject(s)
Chromium , Coronary Artery Disease/surgery , Device Approval , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Platinum , Sirolimus/pharmacology , Adult , Aged , Aged, 80 and over , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/pharmacology , Male , Middle Aged , Prospective Studies , Prosthesis Design , Registries , Time Factors , Treatment Outcome , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...