1.
RSC Adv ; 14(25): 17594-17611, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38828274

ABSTRACT

In recent years, there has been enhanced interest in the domain of natural fibre composites (NFCs) because of their capacity to provide eco-compatible solutions to ever-increasing ecological concerns. This review provides an intensive assessment of the current situation with examination, progress, and applications concerning NFCs. Natural fibres, viz., jute, kenaf, ramie, banana, coir, wheat grass, etc., and their scope in the development of sustainable composites, techniques involved in the fabrication of the composites, characterization techniques, viz., thermo-mechanical and morphological, biodegradability, dampness retention attributes, and potential applications have been extensively reviewed and reported. Besides, this review encompasses the deterrents and conceivable outcomes connected to NFCs, alongside their environmental implications and monetary feasibility. Through a critical evaluation of the existing literature, this article provides a detailed summary of NFCs for real-time engineering applications. It also provides insights into sustainability practices through NFCs.

2.
RSC Adv ; 14(21): 14680-14696, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38708115

ABSTRACT

This study explores the impact of fly ash (FA) filler on the mechanical, morphological, and water absorption properties of pineapple leaf fibre (PALF)-reinforced epoxy composites for biomedical applications. PALF, sourced from abundant agricultural waste, offers a sustainable alternative to synthetic fibres. Employing the hand layup process, varying wt% of FA (3%, 6%, and 9%) are incorporated into PALF-reinforced epoxy composites with different PALF concentrations (10%, 20%, and 30%). Mechanical assessments, including impact, flexural, and tensile strength, reveal that the introduction of up to 6 wt% FA enhances tensile strength by 65.3%, reaching its peak at this concentration. Flexural strength also improves by 31.9% with 6 wt% FA, while impact resistance reaches its maximum (74.18% improvement) at 9 wt% FA. Water absorption measurements demonstrate a decrease with increased FA content and exposure period, indicating enhanced water resistance. Scanning electron microscopy confirms the uniform distribution of FA, contributing to improved mechanical characteristics and water resistance. Optimality tests using Taguchi and response surface methodology (RSM) further confirm the experimental outcomes, emphasizing the potential of FA to enhance natural fibre-reinforced composites. This research suggests FA as a promising filler to elevate mechanical performance and water resistance in environmentally friendly composites.

3.
World J Orthop ; 15(4): 321-336, 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38680676

ABSTRACT

BACKGROUND: The four components that make up the current dual-mobility artificial hip joint design are the femoral head, the inner liner, the outer liner as a metal cover to prevent wear, and the acetabular cup. The acetabular cup and the outer liner were constructed of 316L stainless steel. At the same time, the inner liner was made of ultra-high-molecular-weight polyethylene (UHMWPE). As this new dual-mobility artificial hip joint has not been researched extensively, more tribological research is needed to predict wear. The thickness of the inner liner is a significant component to consider when calculating the contact pressure. AIM: To make use of finite element analysis to gain a better understanding of the contact behavior in various inner liner thicknesses on a new model of a dual-mobility artificial hip joint, with the ultimate objective of determining the inner liner thickness that was most suitable for this particular type of dual-mobility artificial hip joint. METHODS: In this study, the size of the femoral head was compared between two diameters (28 mm and 36 mm) and eight inner liner thicknesses ranging from 5 mm to 12 mm. Using the finite element method, the contact parameters, including the maximum contact pressure and contact area, have been evaluated in light of the Hertzian contact theory. The simulation was performed statically with dissipated energy and asymmetric behavior. The types of interaction were surface-to-surface contact and normal contact behavior. RESULTS: The maximum contact pressures in the inner liner (UHMWPE) at a head diameter of 28 mm and 36 mm are between 3.7-13.5 MPa and 2.7-10.4 MPa, respectively. The maximum von Mises of the inner liner, outer liner, and acetabular cup are 2.4-11.4 MPa, 15.7-44.3 MPa, and 3.7-12.6 MPa, respectively, for 28 mm head. Then the maximum von Mises stresses of the 36 mm head are 1.9-8.9 MPa for the inner liner, 9.9-32.8 MPa for the outer liner, and 2.6-9.9 MPa for the acetabular cup. A head with a diameter of 28 mm should have an inner liner with a thickness of 12 mm. Whereas the head diameter was 36 mm, an inner liner thickness of 8 mm was suitable. CONCLUSION: The contact pressures and von Mises stresses generated during this research can potentially be exploited in estimating the wear of dual-mobility artificial hip joints in general. Contact pressure and von Mises stress reduce with an increasing head diameter and inner liner's thickness. Present findings would become one of the references for orthopedic surgery for choosing suitable bearing geometric parameter of hip implant.

4.
ACS Omega ; 9(11): 12602-12610, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38524437

ABSTRACT

Background: Head and neck squamous cell carcinoma (HNSCC) is one of the major types of cancer, with 900,000 cases and over 400,000 deaths annually. It constitutes 3-4% of all cancers in Europe and western countries. As early diagnosis is the key to treating the disease, reliable biomarkers play an important role in the precision medicine of HNSCC. Despite treatments, the survival rate of cancer patients remains unchanged, and this is mainly due to the failure to detect the disease early. Thus, the objective of this study is to identify reliable biomarkers for head and neck cancers for better healthcare management. Methods: In this study, all available, curated human genes were screened for their expression against HNSCC TCGA patient samples using genomic and proteomic data by various bioinformatic approaches and datamining. Docking studies were performed using AutoDock or online virtual screening tools for identifying potential ligands. Results: Sixty genes were short-listed, and most of them show a consistently higher expression in head and neck patient samples at both the mRNA and the protein level. Irrespective of human papillomavirus (HPV) status, all of them show a higher expression in cancer samples. The higher expression of 30 genes shows adverse effects on patient survival. Out of the 60 genes, 12 genes have crystal structures and druggable potential. We show that genes such as GTF2H4, HAUS7, MSN, and MNDA could be targets of Pembrolizumab and Nivolumab, which are approved monoclonal antibodies for HNSCC. Conclusion: Sixty genes are identified as potential biomarkers for head and neck cancers based on their consistent and statistically significantly higher expression in patient samples. Four proteins have been identified as potential drug targets based on their crystal structure. However, the utility of these candidate genes has to be further tested using patient samples.

5.
Sci Rep ; 14(1): 6842, 2024 03 21.
Article in English | MEDLINE | ID: mdl-38514731

ABSTRACT

Previous research has primarily focused on pre-processing parameters such as design, material selection, and printing techniques to improve the strength of 3D-printed prosthetic leg sockets. However, these methods fail to address the major challenges that arise post-printing, namely failures at the distal end of the socket and susceptibility to shear failure. Addressing this gap, the study aims to enhance the mechanical properties of 3D-printed prosthetic leg sockets through post-processing techniques. Fifteen PLA + prosthetic leg sockets are fabricated and reinforced with four materials: carbon fiber, carbon-Kevlar fiber, fiberglass, and cement. Mechanical and microstructural properties of the sockets are evaluated through axial compression testing and scanning electron microscopy (SEM). Results highlight superior attributes of cement-reinforced sockets, exhibiting significantly higher yield strength (up to 89.57% more than counterparts) and higher Young's modulus (up to 76.15% greater). SEM reveals correlations between microstructural properties and socket strength. These findings deepen the comprehension of 3D-printed prosthetic leg socket post-processing, presenting optimization prospects. Future research can focus on refining fabrication techniques, exploring alternative reinforcement materials, and investigating the long-term durability and functionality of post-processed 3D-printed prosthetic leg sockets.


Subject(s)
Artificial Limbs , Prosthesis Design , Prosthesis Implantation , Pressure , Carbon Fiber , Printing, Three-Dimensional
6.
Heliyon ; 10(4): e26660, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38404809

ABSTRACT

Previous works had successfully demonstrated the clinical effectiveness of unilateral external fixator in treating various types of fracture, ranging from the simple type, such as oblique and transverse fractures, to complex fractures. However, literature that investigated its biomechanical analyses to further justify its efficacy is limited. Therefore, this paper aimed to analyse the stability of unilateral external fixator for treating different types of fracture, including the simple oblique, AO32C3 comminuted, and 20 mm gap transverse fracture. These fractures were reconstructed at the distal diaphysis of the femoral bone and computationally analysed through the finite element method under the stance phase condition. Findings showed a decrease in the fixation stiffness in large gap fracture (645.2 Nmm-1 for oblique and comminuted, while 23.4 Nmm-1 for the gap fracture), which resulted in higher displacement, IFM and stress distribution at the pin bone interface. These unfavourable conditions could consequently increase the risk of delayed union, pin loosening and infection, as well as implant failure. Nevertheless, the stress observed on the fracture surfaces was relatively low and in controlled amount, indicating that bone unity is still allowable in all models. Briefly, the unilateral fixation may provide desirable results in smaller fracture gap, but its usage in larger gap fracture might be alarming. These findings could serve as a guide and insight for surgeons and researchers, especially on the biomechanical stability of fixation in different fracture types and how will it affect bone unity.

7.
Sci Rep ; 14(1): 916, 2024 01 09.
Article in English | MEDLINE | ID: mdl-38195665

ABSTRACT

The single mobility bearing as a previous bearing design of total hip prosthesis has severe mobility constraints that can result in dislocation during Muslim (people who follow the Islam as religion) prayer movements, specifically shalat that requires intense movement. There are five intense movements (i.e., bowing, prostration, sitting, transition from standing to prostration, and final sitting) during Muslim prayer that may generate an impingement problem for patients with total hip prosthesis. In this work, textured dual mobility total hip prosthesis with two textured cases (i.e., textured femoral head and textured inner liner) are presented and their performances are numerically evaluated against untextured surface model during Muslim prayer movement. The concave dimple design is chosen for surface texturing, while for simulating femoral head materials, SS 316L and CoCrMo is choosen. To represent the real condition, three-dimensional computational fluid dynamics (CFD) coupled with two-way fluid-structure interaction (FSI) methods are employed to analyze elastohydrodynamic lubrication problem with non-Newtonian synovial fluid model. The main aim of the present study is to investigate the tribological performance on dual mobility total hip prosthesis with applied textured surface with concave dimple in femoral head and inner liner surface under Muslim prayer movements. It is found that applying surface texturing has a beneficial effect on the lubrication performance for some intense movements. The textured femoral head model performs better than textured inner liner model and untextured model (both femoral head and inner liner). The numerical results also indicate superior performance of CoCrMo femoral head compared to SS 316L femoral head. These findings can be used as a reference for biomedical engineers and orthopedic surgeons in designing and choosing suitable total hip prosthesis for Muslims makes they can carry out Muslim prayer movements like humans in general who have normal hip joints.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Islam , Hip Joint , Biomedical Engineering
8.
Proc Inst Mech Eng H ; 238(1): 99-111, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38156402

ABSTRACT

The running-in process is considered an essential aspect of the comprehensive wear process. The phenomenon of running-in occurs during the initial stages of wear in the prosthetic hip joint. Within the field of tribology, the running-in phenomenon of the hip joint pertains to the mechanism by which the contact surfaces of the artificial hip joint components are adjusted and a suitable lubricating film is formed. During the process of hip joint running-in, there is an interaction between the metal surface of the ball and the joint cup, which results in adjustments being made until a steady state is achieved. The achievement of desirable wear existence and reliable performance of artificial hip joint components are reliant upon the tribological running-in of the hip joint. Despite the establishment of current modeling approaches, there remains a significant lack of understanding concerning running-in wear, particularly the metal-on-polyethylene (MoP) articulations in dual-mobility cups (DMC). An essential aspect to consider is the running-in phase of the dual mobility component. The present study employed finite element analysis to investigate the running-in behavior of dual mobility cups, wherein femoral head components were matched with polyethylene liners of varying thicknesses. The analysis of the running-in phase was conducted during the normal gait cycle. The results of this investigation may be utilized to design a dual-mobility prosthetic hip joint that exhibits minimal running-in wear.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Finite Element Analysis , Prosthesis Design , Polyethylene , Gait , Prosthesis Failure
9.
Materials (Basel) ; 16(12)2023 Jun 19.
Article in English | MEDLINE | ID: mdl-37374641

ABSTRACT

The superior engineering properties and excellent biocompatibility of titanium alloy (Ti6Al4V) stimulate applications in biomedical industries. Electric discharge machining, a widely used process in advanced applications, is an attractive option that simultaneously offers machining and surface modification. In this study, a comprehensive list of roughening levels of process variables such as pulse current, pulse ON time, pulse OFF time, and polarity, along with four tool electrodes of graphite, copper, brass, and aluminum are evaluated (against two experimentation phases) using a SiC powder-mixed dielectric. The process is modeled using the adaptive neural fuzzy inference system (ANFIS) to produce surfaces with relatively low roughness. A thorough parametric, microscopical, and tribological analysis campaign is established to explore the physical science of the process. For the case of the surface generated through aluminum, a minimum friction force of ~25 N is observed compared with the other surfaces. The analysis of variance shows that the electrode material (32.65%) is found to be significant for the material removal rate, and the pulse ON time (32.15%) is found to be significant for arithmetic roughness. The increase in pulse current to 14 A shows that the roughness increased to ~4.6 µm with a 33% rise using the aluminum electrode. The increase in pulse ON time from 50 µs to 125 µs using the graphite tool resulted in a rise in roughness from ~4.5 µm to ~5.3 µm, showing a 17% rise.

10.
Materials (Basel) ; 16(9)2023 Apr 22.
Article in English | MEDLINE | ID: mdl-37176180

ABSTRACT

Total hip arthroplasty (THA) is most likely one of the most successful surgical procedures in medicine. It is estimated that three in four patients live beyond the first post-operative year, so appropriate surgery is needed to alleviate an otherwise long-standing suboptimal functional level. However, research has shown that during a complete THA procedure, a solid hip implant inserted in the femur can damage the main arterial supply of the cortex and damage the medullary space, leading to cortical bone resorption. Therefore, this study aimed to design a porous hip implant with a focus on providing more space for better osteointegration, improving the medullary revascularisation and blood circulation of patients. Based on a review of the literature, a lightweight implant design was developed by applying topology optimisation and changing the materials of the implant. Gyroid and Voronoi lattice structures and a solid hip implant (as a control) were designed. In total, three designs of hip implants were constructed by using SolidWorks and nTopology software version 2.31. Point loads were applied at the x, y and z-axis to imitate the stance phase condition. The forces represented were x = 320 N, y = -170 N, and z = -2850 N. The materials that were used in this study were titanium alloys. All of the designs were then simulated by using Marc Mentat software version 2020 (MSC Software Corporation, Munich, Germany) via a finite element method. Analysis of the study on topology optimisation demonstrated that the Voronoi lattice structure yielded the lowest von Mises stress and displacement values, at 313.96 MPa and 1.50 mm, respectively, with titanium alloys as the materials. The results also indicate that porous hip implants have the potential to be implemented for hip implant replacement, whereby the mechanical integrity is still preserved. This result will not only help orthopaedic surgeons to justify the design choices, but could also provide new insights for future studies in biomechanics.

11.
Sci Rep ; 13(1): 3564, 2023 03 02.
Article in English | MEDLINE | ID: mdl-36864170

ABSTRACT

Hip joint prostheses are used to replace hip joint function in the human body. The latest dual-mobility hip joint prosthesis has an additional component of an outer liner that acts as a cover for the liner component. Research on the contact pressure generated on the latest model of a dual-mobility hip joint prosthesis under a gait cycle has never been done before. The model is made of ultrahigh molecular weight polyethylene (UHMWPE) on the inner liner and 316L stainless steel (SS 316L) on the outer liner and acetabular cup. Simulation modeling using the finite element method is considered static loading with an implicit solver for studying the geometric parameter design of dual-mobility hip joint prostheses. In this study, simulation modeling was carried out by applying varying inclination angles of 30°, 40°, 45°, 50°, 60°, and 70° to the acetabular cup component. Three-dimensional loads were placed on femoral head reference points with variations of femoral head diameter used at 22 mm, 28 mm, and 32 mm. The results in the inner surface of the inner liner, the outer surface of the outer liner, and the inner surface of the acetabular cup showed that the variations in inclination angle do not have a major effect on the maximum contact pressure value on the liner component, where the acetabular cup with an inclination angle of 45° can reduce contact pressure more than the other studied inclination angle variations. In addition, it was found that the 22 mm diameter of the femoral head increases the contact pressure. The use of a larger diameter femoral head with an acetabular cup configuration at a 45° inclination can minimize the risk of implant failure due to wear.


Subject(s)
Acetabulum , Hip Prosthesis , Humans , Acetabulum/surgery , Computer Simulation , Femur Head , Gait
12.
Biomedicines ; 11(3)2023 Mar 20.
Article in English | MEDLINE | ID: mdl-36979930

ABSTRACT

Due to polymeric wear debris causing osteolysis from polymer, metal ions causing metallosis from metal, and brittle characteristic causing fracture failure from ceramic in the application on bearing of total hip prosthesis requires the availability of new material options as a solution to these problems. Polycrystalline diamond (PCD) has the potential to become the selected material for hard-on-hard bearing in view of its advantages in terms of mechanical properties and biocompatibility. The present study contributes to confirming the potential of PCD to replace metals and ceramics for hard-on-hard bearing through von Mises stress investigations. A computational simulation using a 2D axisymmetric finite element model of hard-on-hard bearing under gait loading has been performed. The percentage of maximum von Mises stress to respective yield strength from PCD-on-PCD is the lowest at 2.47%, with CoCrMo (cobalt chromium molybdenum)-on-CoCrMo at 10.79%, and Al2O3 (aluminium oxide)-on-Al2O3 at 13.49%. This confirms that the use of PCD as a hard-on-hard bearing material is the safest option compared to the investigated metal and ceramic hard-on-hard bearings from the mechanical perspective.

13.
Biomedicines ; 11(2)2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36830961

ABSTRACT

In designing porous scaffolds, permeability is essential to consider as a function of cell migration and bone tissue regeneration. Good permeability has been achieved by mimicking the complexity of natural cancellous bone. In this study, a porous scaffold was developed according to the morphological indices of cancellous bone (porosity, specific surface area, thickness, and tortuosity). The computational fluid dynamics method analyzes the fluid flow through the scaffold. The permeability values of natural cancellous bone and three types of scaffolds (cubic, octahedron pillar, and Schoen's gyroid) were compared. The results showed that the permeability of the Negative Schwarz Primitive (NSP) scaffold model was similar to that of natural cancellous bone, which was in the range of 2.0 × 10-11 m2 to 4.0 × 10-10 m2. In addition, it was observed that the tortuosity parameter significantly affected the scaffold's permeability and shear stress values. The tortuosity value of the NSP scaffold was in the range of 1.5-2.8. Therefore, tortuosity can be manipulated by changing the curvature of the surface scaffold radius to obtain a superior bone tissue engineering construction supporting cell migration and tissue regeneration. This parameter should be considered when making new scaffolds, such as our NSP. Such efforts will produce a scaffold architecturally and functionally close to the natural cancellous bone, as demonstrated in this study.

14.
Heliyon ; 8(12): e12050, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36506403

ABSTRACT

Bearing on artificial hip joint experiences friction, wear, and surface damage that impact on overall performance and leading to failure at a particular time due to continuous contact that endangers the user. Assessing bearing hip joint using clinical study, experimental testing, and mathematical formula approach is challenging because there are some obstacles from each approach. Computational simulation is an effective alternative approach that is affordable, relatively fast, and more accessible than other approaches in examining various complex conditions requiring extensive resources and several different parameters. In particular, different gait cycles affect the sliding distance and distribution of gait loading acting on the joints. Appropriate selection and addition of gait cycles in computation modelling are crucial for accurate and reliable prediction and analysis of bearing performance such as wear a failure of implants. However, a wide spread of gait cycles and loading data are being considered and studied by researchers as reported in literature. The current article describes a comprehensive literature review adopted walking condition that has been carried out to study bearing using computational simulation approach over the past 30 years. Many knowledge gaps related to adoption procedures, simplification, and future research have been identified to obtain bearing analysis results with more realistic computational simulation approach according to physiological human hip joints.

15.
J Funct Biomater ; 13(2)2022 May 23.
Article in English | MEDLINE | ID: mdl-35645272

ABSTRACT

Due to various concerns about the use of metal-on-metal that is detrimental to users, the use of metal as acetabular cup material was later changed to ultra high molecular weight polyethylene (UHMWPE). However, the wear on UHMWPE releases polyethylene wear particles, which can trigger a negative body response and contribute to osteolysis. For reducing the wear of polyethylene, one of the efforts is to investigate the selection of metal materials. Cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V) are the frequently employed materials. The computational evaluation of contact pressure was carried out using a two-dimensional axisymmetric model for UHMWPE acetabular cup paired with metal femoral head under gait cycle in this study. The results show Ti6Al4V-on-UHMWPE is able to reduce cumulative contact pressure compared to SS 316L-on-UHMWPE and CoCrMo-on-UHMWPE. Compared to Ti6Al4V-on-UHMWPE at peak loading, the difference in cumulative contact pressure to respective maximum contact pressure is 9.740% for SS 316L-on-UHMWPE and 11.038% for CoCrMo-on-UHMWPE.

16.
Bioengineering (Basel) ; 9(4)2022 Apr 05.
Article in English | MEDLINE | ID: mdl-35447717

ABSTRACT

Traveling with children with autism can be very challenging for parents due to their reactions to sensory stimuli resulting in behavioral problems, which lead to self-injury and danger for themselves and others. Deep pressure was reported to have a calming effect on people with autism. This study was designed to investigate the physiological effect of deep pressure, which is an autism hug machine portable seat (AHMPS) in children with autism spectrum disorders (ASD) in public transportation settings. The study was conducted with 20 children with ASD (16 boys and 4 girls) at the Semarang Public Special School with an age ranging from 4 to 13 years (mean 10.9 ± 2.26 years), who were randomly assigned into two groups. The experiment consisted of group I who used the AHMPS inflatable wraps model and group II who used the AHMPS manual pull model. Heart rate (HR) and skin conductance (SC) were analyzed to measure the physiological calming effect using pulse oximeter oximetry and a galvanic skin response (GSR) sensor. Heart rate was significantly decreased during the treatment compared to the baseline (pre-test) session in group I (inflating wrap model) with p = 0.019, while no change of heart rate variability (HRV) was found in group II (manual pull model) with p = 0.111. There was no remaining effect of deep pressure using the HRV indicator after the treatment in both groups (group I with p = 0.159 and group II with p = 0.566). GSR captured the significant decrease in skin conductance during the treatment with p < 0.0001 in group I, but no significant decrease was recorded in group II with p = 0.062. A skin conductance indicator captured the remaining effect of deep pressure (after the treatment); it was better in group I (p = 0.003) than in group II (p = 0.773). In conclusion, the deep pressure of the AHMPS inflating wrap decreases physiological arousal in children with ASD during traveling.

17.
Bioengineering (Basel) ; 9(2)2022 Jan 20.
Article in English | MEDLINE | ID: mdl-35200402

ABSTRACT

Children with autism spectrum disorder (ASD) have challenging behaviors, which are associated with difficulties in parenting. Deep pressure is a therapeutic modality in occupational therapy, and it was reported to produce a calming effect. This study aimed to determine whether the short-term use of an autism hug machine portable seat (AHMPS) improves behavioral and neurobiological stress in children with ASD, and to determine whether AHMPS with an inflatable wrap or manual pull is more effective. This study enrolled children with ASD who were administered with the inflatable wrap (group I) and manual pull (group II) for 20 min twice a week for 3 weeks. Conners' Parent Rating Scale-48 (CPRS-48) was used to rate behavioral improvements, and galvanic skin response (GSR) was used to measure sympathetic stress response. A total of 20 children with ASD (14 boys and 6 girls; aged 7-13 years) were included. CPRS-48 presented conduct problems: behavior was significantly decreased in the inflatable group (p = 0.007) compared to the manual pull group. The GSR captured a significant reduction in sympathetic response (p = 0.01) only in group I. Neurobiological stress was reduced in children who were wearing the AHMPS inflatable wrap; therefore, AHMPS inflatable wrap is an effective method to reduce emotional arousal.

18.
Materials (Basel) ; 14(24)2021 Dec 09.
Article in English | MEDLINE | ID: mdl-34947150

ABSTRACT

The selection of biomaterials for bearing in total hip arthroplasty is very important to avoid various risks of primary postoperative failure for patients. The current investigation attempts to analyze the Tresca stress of metal-on-metal bearings with three different materials, namely, cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V). We used computational simulations using a 2D axisymmetric finite element model to predict Tresca stresses under physiological conditions of the human hip joint during normal walking. The simulation results show that Ti6Al4V-on-Ti6Al4V has the best performance to reduce Tresca stress by 45.76% and 39.15%, respectively, compared to CoCrMo-on-CoCrMo and SS 316L-on-SS 316L.

19.
J Funct Biomater ; 12(2)2021 Jun 06.
Article in English | MEDLINE | ID: mdl-34204138

ABSTRACT

Wear and wear-induced debris is a significant factor in causing failure in implants. Reducing contact pressure by using a textured surface between the femoral head and acetabular cup is crucial to improving the implant's life. This study presented the effect of surface texturing as dimples on the wear evolution of total hip arthroplasty. It was implemented by developing finite element analysis from the prediction model without dimples and with bottom profile dimples of flat, drill, and ball types. Simulations were carried out by performing 3D physiological loading of the hip joint under normal walking conditions. A geometry update was initiated based on the patient's daily routine activities. Our results showed that the addition of dimples reduced contact pressure and wear. The bottom profile dimples of the ball type had the best ability to reduce wear relative to the other types, reducing cumulative linear wear by 24.3% and cumulative volumetric wear by 31% compared to no dimples. The findings demonstrated that surface texturing with appropriate dimple bottom geometry on a bearing surface is able to extend the lifetime of hip implants.