Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Article in English | MEDLINE | ID: mdl-38764317

ABSTRACT

BACKGROUND: Data using real-world assessments of aortic regurgitation (AR) severity to identify rates of Heart Valve Team evaluation and aortic valve replacement (AVR), as well as mortality among untreated patients, are lacking. The present study assessed these trends in care and outcomes for real-world patients with documented AR. METHODS: Using a deidentified data set (January 2018-March 2023) representing 1,002,853 patients >18 years of age from 25 US institutions participating in the egnite Database (egnite, Inc.) with appropriate permissions, patients were classified by AR severity in echocardiographic reports. Rates of evaluation by the Heart Valve Team, AVR, and all-cause mortality without AVR were examined using Kaplan-Meier estimates and compared using the log-rank test. RESULTS: Within the data set, 845,113 patients had AR severity documented. For moderate-to-severe or severe AR, respectively, 2-year rates (95% confidence interval) of evaluation by the Heart Valve Team (43.5% [41.7%-45.3%] and 65.4% [63.3%-67.4%]) and AVR (19.4% [17.6%-21.1%] and 46.5% [44.2%-48.8%]) were low. Mortality at 2 years without AVR increased with greater AR severity, up to 20.7% for severe AR (p < 0.001). In exploratory analyses, 2-year mortality for untreated patients with left ventricular end-systolic dimension index > 25 mm/m2 was similar for moderate (34.3% [29.2%-39.1%]) and severe (37.2% [24.9%-47.5%]) AR. CONCLUSIONS: Moderate or greater AR is associated with poor clinical outcomes among untreated patients at 2 years. Rates of Heart Valve Team evaluation and AVR were low for those with moderate or greater AR, suggesting that earlier referral to the Heart Valve Team could be beneficial.

2.
Eur J Heart Fail ; 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38606485

ABSTRACT

AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.

3.
Radiology ; 304(1): 4-17, 2022 07.
Article in English | MEDLINE | ID: mdl-35638923

ABSTRACT

Minimally invasive strategies to treat valvular heart disease have emerged over the past 2 decades. The use of transcatheter aortic valve replacement in the treatment of severe aortic stenosis, for example, has recently expanded from high- to low-risk patients and became an alternative treatment for those with prohibitive surgical risk. With the increase in transcatheter strategies, multimodality imaging, including echocardiography, CT, fluoroscopy, and cardiac MRI, are used. Strategies for preprocedural imaging strategies vary depending on the targeted valve. Herein, an overview of preprocedural imaging strategies and their postprocessing approaches is provided, with a focus on CT. Transcatheter aortic valve replacement is reviewed, as well as less established minimally invasive treatments of the mitral and tricuspid valves. In addition, device-specific details and the goals of CT imaging are discussed. Future imaging developments, such as peri-procedural fusion imaging, machine learning for image processing, and mixed reality applications, are presented.


Subject(s)
Aortic Valve Stenosis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cardiac Catheterization , Echocardiography , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Humans , Multimodal Imaging , Tomography, X-Ray Computed/methods
5.
Circ Cardiovasc Interv ; 12(2): e007552, 2019 02.
Article in English | MEDLINE | ID: mdl-30704286

ABSTRACT

BACKGROUND: Renal disease is associated with poor prognosis despite guideline-directed cardiovascular therapy, and outcomes by sex in this population remain uncertain. METHODS AND RESULTS: Patients (n=5213) who underwent a MitraClip procedure in the National Cardiovascular Data Registry Transcatheter Valve Therapy registry were evaluated for the primary composite outcome of all-cause mortality, stroke, and new requirement for dialysis by creatinine clearance (CrCl). Centers for Medicare and Medicaid Services-linked data were available in 63% of patients (n=3300). CrCl was <60 mL/min in 77% (n=4010) and <30 mL/min in 23% (n=1183) of the cohort. Rates of primary outcome were higher with lower CrCl (>60 mL/min, 1.4%; 30-<60 mL/min, 2.7%; <30 mL/min, 5.2%; dialysis, 7.8%; P<0.001), and all low CrCl groups were independently associated with the primary outcome (30-<60 mL/min: adjusted odds ratio, 2.32; 95% CI, 1.38-3.91; <30 mL/min: adjusted odds ratio, 4.44; 95% CI, 2.63-7.49; dialysis: adjusted hazards ratio, 4.52; 95% CI, 2.08-9.82) when compared with CrCl >60 mL/min. Rates of 1-year mortality were higher with lower CrCl (>60 mL/min, 13.2%; 30-<60 mL/min, 18.8%; <30 mL/min, 29.9%; dialysis, 32.3%; P<0.001), and all low CrCl groups were independently associated with 1-year mortality (30-<60 mL/min: adjusted hazards ratio, 1.50; 95% CI, 1.13-1.99; <30 mL/min: adjusted hazards ratio, 2.38; 95% CI, 1.78-3.20; adjusted hazards ratio: dialysis, 2.44; 95% CI, 1.66-3.57) when compared with CrCl >60 mL/min. CONCLUSIONS: The majority of patients who undergo MitraClip have renal disease. Preprocedural renal disease is associated with poor outcomes, particularly in stage 4 or 5 renal disease where 1-year mortality is observed in nearly one-third. Studies to determine how to further optimize outcomes in this population are warranted.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Kidney Diseases/physiopathology , Kidney/physiopathology , Mitral Valve Insufficiency/surgery , Mitral Valve Stenosis/surgery , Aged , Aged, 80 and over , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Humans , Kidney Diseases/diagnosis , Kidney Diseases/mortality , Kidney Diseases/therapy , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/mortality , Mitral Valve Stenosis/physiopathology , Prosthesis Design , Registries , Renal Dialysis , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
6.
J Invasive Cardiol ; 27(11): E236-41, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26524208

ABSTRACT

BACKGROUND: Atherosclerotic disease of the superficial femoral artery (SFA) is frequently seen and can be treated with percutaneous interventions, traditionally via femoral artery access. There are limited reports of transpedal artery access for peripheral artery interventions, but none to date describing routine primary transpedal artery approach for SFA stenting. METHODS: In this preliminary study, we report 4 patients who underwent successful endovascular SFA stenting using a single transpedal artery access via a new ultra-low profile 6 Fr sheath (Glidesheath Slender; Terumo Corporation). RESULTS: All patients underwent successful SFA stenting without complication. Procedure time varied from 51 to 72 minutes. The mean contrast amount used was 56 mL; mean fluoroscopy time was 21 minutes; mean radiation dose was 91 mGy. At 1-month follow-up, duplex ultrasonography showed that all pedal arteries had remained patent. CONCLUSIONS: Transpedal artery approach as a primary approach to SFA stenting appears feasible and safe. Comparative trials with standard percutaneous femoral approach are warranted.


Subject(s)
Endovascular Procedures/methods , Intermittent Claudication/surgery , Popliteal Artery/surgery , Aged , Aged, 80 and over , Angiography , Angioplasty, Balloon , Female , Femoral Artery , Humans , Intermittent Claudication/diagnostic imaging , Male , Popliteal Artery/diagnostic imaging , Ultrasonography, Doppler, Duplex
7.
Am J Cardiol ; 113(9): 1474-80, 2014 May 01.
Article in English | MEDLINE | ID: mdl-24630791

ABSTRACT

Periprocedural hyperglycemia is an independent predictor of mortality in patients who underwent percutaneous coronary intervention (PCI). However, periprocedural management of blood glucose is not standardized. The effects of routinely continuing long-acting glucose-lowering medications before coronary angiography with possible PCI on periprocedural glycemic control have not been investigated. Patients with diabetes mellitus (DM; n = 172) were randomized to continue (Continue group; n = 86) or hold (Hold group; n = 86) their clinically prescribed long-acting glucose-lowering medications before the procedure. The primary end point was glucose level on procedural access. In a subset of patients (no DM group: n = 25; Continue group: n = 25; and Hold group: n = 25), selected measures of platelet activity that change acutely were assessed. Patients with DM randomized to the Continue group had lower blood glucose levels on procedural access compared with those randomized to the Hold group (117 [97 to 151] vs 134 [117 to 172] mg/dl, p = 0.002). There were two hypoglycemic events in the Continue group and none in the Hold group, and no adverse events in either group. Selected markers of platelet activity differed across the no DM, Continue, and Hold groups (leukocyte platelet aggregates: 8.1% [7.2 to 10.4], 8.7% [6.9 to 11.4], 10.9% [8.6 to 14.7], p = 0.007; monocyte platelet aggregates: 14.0% [10.3 to 16.3], 20.8% [16.2 to 27.0], 22.5% [15.2 to 35.4], p <0.001; soluble p-selectin: 51.9 ng/ml [39.7 to 74.0], 59.1 ng/ml [46.8 to 73.2], 72.2 ng/ml [58.4 to 77.4], p = 0.014). In conclusion, routinely continuing clinically prescribed long-acting glucose-lowering medications before coronary angiography with possible PCI help achieve periprocedural euglycemia, appear safe, and should be considered as a strategy for achieving periprocedural glycemic control.


Subject(s)
Blood Glucose/analysis , Coronary Angiography , Diabetes Mellitus, Type 2/therapy , Percutaneous Coronary Intervention , Aged , Blood Platelets/physiology , Diabetes Mellitus, Type 2/blood , Female , Humans , Male , Middle Aged , Preoperative Period
8.
Am J Cardiol ; 111(2): 185-9, 2013 Jan 15.
Article in English | MEDLINE | ID: mdl-23102880

ABSTRACT

Increased platelet activity is associated with adverse cardiovascular events. The mean platelet volume (MPV) correlates with platelet activity; however, the relation between the MPV and long-term mortality in patients undergoing percutaneous coronary intervention (PCI) is not well established. Furthermore, the role of change in the MPV over time has not been previously evaluated. We evaluated the MPV at baseline, 30 days, 60 days, 90 days, 1 year, 2 years, and 3 years after the procedure in 1,512 patients who underwent PCI. The speed of change in the MPV was estimated using the slope of linear regression. Mortality was determined by query of the Social Security Death Index. During a median of 8.7 years, mortality was 49.3% after PCI. No significant difference was seen in mortality when stratified by MPV quartile (first quartile, 50.1%; second quartile, 47.7%; third quartile, 51.3%; fourth quartile, 48.3%; p = 0.74). For the 839 patients with available data to determine a change in the MPV over time after PCI, mortality was 49.1% and was significantly greater in patients with an increase (52.9%) than in those with a decrease (44.2%) or no change (49.1%) in the MPV over time (p <0.0001). In conclusion, no association was found between the baseline MPV and long-term mortality in patients undergoing PCI. However, increased mortality was found when the MPV increased over time after PCI. Monitoring the MPV after coronary revascularization might play a role in risk stratification.


Subject(s)
Blood Platelets/physiology , Myocardial Infarction/mortality , Percutaneous Coronary Intervention , Aged , Follow-Up Studies , Humans , Male , Middle Aged , Myocardial Infarction/blood , Myocardial Infarction/surgery , Platelet Count , Prognosis , Retrospective Studies , Survival Rate/trends , Time Factors , United States/epidemiology
9.
Am J Med Sci ; 343(4): 321-6, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21946827

ABSTRACT

Hyperglycemia is common in nondiabetic patients with acute myocardial infarction (AMI). Elevated blood glucose level may reflect a response to stress, an underlying abnormal glucometabolic state or both. Regardless of mechanism, hyperglycemia complicating AMI is associated with an inflammatory and prothrombotic state, depressed myocardial contractility and increased short- and long-term mortality. Studies are needed to define optimal monitoring and management of hyperglycemia in nondiabetic patients with AMI.


Subject(s)
Hyperglycemia/complications , Hyperglycemia/diagnosis , Myocardial Infarction/complications , Myocardial Infarction/diagnosis , Blood Glucose/metabolism , Diagnosis, Differential , Humans , Hyperglycemia/blood , Myocardial Infarction/blood , Stress, Physiological/physiology
10.
J Comp Eff Res ; 1(6): 501-8, 2012 Nov.
Article in English | MEDLINE | ID: mdl-24236469

ABSTRACT

Drug-eluting stents have dramatically reduced the risk of restenosis, but concerns of an increased risk of stent thrombosis have provided uncertainty about their use. Recent studies have continued to show improved procedural and clinical outcomes with drug-eluting stents both in the setting of acute coronary syndromes and stable coronary artery disease. Newer generation drug-eluting stents (especially everolimus-eluting stents) have been shown to be not only efficacious but also safe with reduced risk of stent thrombosis when compared with bare-metal stents, potentially changing the benchmark for stent safety from bare-metal stents to everolimus-eluting stents. While much progress is being made in the development of bioabsorbable polymer stents, nonpolymer stents and bioabsorbable stent technology, it remains to be seen whether these stents will have superior safety and efficacy outcomes compared with the already much improved rates of revascularization and stent thrombosis seen with newer generation stents (everolimus-eluting stents and resolute zotarolimus-eluting stents).


Subject(s)
Coronary Restenosis/prevention & control , Stents/trends , Absorbable Implants , Angioplasty, Balloon, Coronary/methods , Coronary Restenosis/economics , Cost-Benefit Analysis , Drug Combinations , Drug-Eluting Stents/economics , Drug-Eluting Stents/trends , Forecasting , Graft Occlusion, Vascular/economics , Graft Occlusion, Vascular/etiology , Humans , Myocardial Infarction/economics , Myocardial Infarction/therapy , Myocardial Revascularization/economics , Myocardial Revascularization/methods , Percutaneous Coronary Intervention/economics , Percutaneous Coronary Intervention/methods , Platelet Aggregation Inhibitors/economics , Platelet Aggregation Inhibitors/therapeutic use , Polymers/therapeutic use , Stents/economics , Thrombosis/economics , Thrombosis/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...