1.
Tomography ; 9(6): 1987-1998, 2023 10 24.
Article in English | MEDLINE | ID: mdl-37987341

ABSTRACT

BACKGROUND: Compared to conventional 2D mammography, digital breast tomosynthesis (DBT) offers greater breast lesion detection rates. Ring-like hypodense artifacts surrounding dense lesions are a common byproduct of DBT. This study's purpose was to assess whether minuscule changes spanning this halo-termed the "broken halo sign"-could improve lesion classification. METHODS: This retrospective study was approved by the local ethics review board. After screening 288 consecutive patients, DBT studies of 191 female participants referred for routine mammography with a subsequent histologically verified finding of the breast were assessed. Examined variables included patient age, histological diagnosis, architectural distortion, maximum size, maximum halo depth, conspicuous margins, irregular shape and broken halo sign. RESULTS: While a higher halo strength was indicative of malignancy in general (p = 0.031), the broken halo sign was strongly associated with malignancy (p < 0.0001, odds ratio (OR) 6.33), alongside architectural distortion (p = 0.012, OR 3.49) and a diffuse margin (p = 0.006, OR 5.49). This was especially true for denser breasts (ACR C/D), where the broken halo sign was the only factor predicting malignancy (p = 0.03, 5.22 OR). CONCLUSION: DBT-associated halo artifacts warrant thorough investigation in newly found breast lesions as they are associated with malignant tumors. The "broken halo sign"-the presence of small lines of variable diameter spanning the peritumoral areas of hypodensity-is a strong indicator of malignancy, especially in dense breasts, where architectural distortion may be obfuscated due to the surrounding tissue.


Subject(s)
Breast Neoplasms , Breast , Female , Humans , Retrospective Studies , Breast/diagnostic imaging , Mammography , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology
2.
Diagnostics (Basel) ; 13(12)2023 Jun 14.
Article in English | MEDLINE | ID: mdl-37370959

ABSTRACT

To evaluate the diagnostic utility of the maximum ultrasound strain elastography (SE) halo depth in newly diagnosed and histologically confirmed breast lesions, a retrospective study approval was granted by the local Ethical Review Board. Overall, the maximum strain elastography peritumoural halos (SEPHmax)-the maximum distance between the SE stiffening area and the B-mode lesion size-in 428 cases with newly diagnosed breast lesions were retrospectively analysed alongside patient age, affected quadrant, tumour echogenicity, size, acoustic shadowing, and vascularity. Statistical analysis included an ordinary one-way ANOVA to compare the SEPHmax between BI-RADS 2, 3, and 5 groups and between tumour grades 1, 2, and 3. A binary regression analysis was used to determine the correlation between tumour malignancy and the above-mentioned demographic and imaging factors. SEPHmax was significantly higher in BI-RADS 5 tumours (5.5 ± 3.9 mm) compared to BI-RADS 3 (0.9 ± 1.7 mm, p < 0.0001) and 2 (0.6 ± 1.4 mm, p < 0.0001). The receiver operating characteristic area under the curve was 0.933 for the detection of BI-RADS 5 lesions. Furthermore, tumour grades 2 (5.6 ± 3.6 mm, p = 0.001) and 3 (6.8 ± 4.2 mm, p < 0.0001) exhibited significantly higher SEPHmax than grade 1 tumours (4.0 ± 3.9 mm). Similarly, St. Gallen Ki67-stratified low-risk (p = 0.005) and intermediate-risk (p = 0.013) tumours showed smaller SEPHmax than high-risk tumours. Multivariate analysis revealed a significant correlation between malignant differentiation and SEPHmax (standardized regression coefficient 3.17 [95% confidence interval (CI) 2.42-3.92], p < 0.0001), low tumour echogenicity (1.68 [95% CI 0.41-3.00], p = 0.03), and higher patient age (0.89 [95% CI 0.52-1.26], p < 0.0001). High SEPHmax is a strong predictor for tumour malignancy and a higher tumour grade and can be used to improve tumour characterisation before histopathological evaluation. It may also enable radiologists to identify lesions warranting observation rather than immediate biopsy.

3.
Eur J Radiol ; 163: 110838, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37080064

ABSTRACT

PURPOSE: To compare contrast-enhanced spectral mammography (CESM) with mammography (Mx), ultrasound (US), and magnetic resonance imaging (MRI) regarding breast cancer detection rate and preoperative local staging. MATERIAL AND METHODS: This prospective observational, single-centre study included 128 female patients (mean age 55.8 ± 11.5 years) with a newly diagnosed malignant breast tumour during routine US and Mx were prospectively enrolled. CESM and MRI examinations were performed within the study. Analysis included interreader agreement, tumour type and grade distribution, detection rates (DR), imaging morphology, contrast-enhancement and was performed by two independent readers blinded to patient history and histopathological diagnosis. Assessment of local disease extent was compared between modalities via Bland-Altman plots. RESULTS: One-hundred-and-ten tumours were classified as NST (85.9%), 4 as ILC (3.1%) and 10 as DCIS (7.8%). DR was highest for MRI (128/128, 100.0%), followed by US (124/128, 96.9%) and CESM (123/128, 96.1%) and lowest for conventional Mx (106/128, 82.8%) (p = 0.0002). Higher breast density did not negatively affect DR of US, CESM or MRI. Local tumour extent measurements based on CESM (Bland-Altman bias 6.6, standard deviation 30.2) showed comparable estimation results to MRI, surpassing Mx (23.4/43.7) and US (35.4/40.5). Even though detection of multifocality and multicentricity was highest for CESM and MRI (p < 0.0001), second-look rates, i.e., targeted US examinations after MRI or CESM, were significantly lower for CESM (10.2% of cases) compared to MRI (16.2%) with a significantly higher true positive rate for CESM (72.0%) vs. MRI (42.5%). CONCLUSION: CESM is a viable alternative to MRI for lesion detection and local staging in newly diagnosed malignant breast cancer and provides higher specificity in regard to second-look examinations.


Subject(s)
Breast Neoplasms , Humans , Female , Adult , Middle Aged , Aged , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Ultrasonography, Mammary , Contrast Media , Mammography/methods , Magnetic Resonance Imaging/methods , Multimodal Imaging , Sensitivity and Specificity
4.
J Clin Med ; 12(4)2023 Feb 07.
Article in English | MEDLINE | ID: mdl-36835850

ABSTRACT

The most common long-term complication of silicone breast implants (SMI) remains capsular fibrosis. The etiology of this exaggerated implant encapsulation is multifactorial but primarily induced by the host response towards the foreign material silicone. Identified risk factors include specific implant topographies. Of note, breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) has only been observed in response to textured surface implants. We hypothesize that reduction of SMI surface roughness causes less host response and, hence, better cosmetic outcomes with fewer complications for the patient. A total of 7 patients received the routinely used CPX®4 breast expander (~60 µM Ra) and the novel SmoothSilk® (~4 µM Ra), fixed prepectoral with a titanized mesh pocket and randomized to the left or right breast after bilateral prophylactic NSME (nipple-sparing mastectomy). We aimed to compare the postoperative outcome regarding capsule thickness, seroma formation, rippling, implant dislocation as well as comfortability and practicability. Our analysis shows that surface roughness is an influential parameter in controlling fibrotic implant encapsulation. Compared intra-individually for the first time in patients, our data confirm an improved biocompatibility with minor capsule formation around SmoothSilk® implants with an average shell roughness of 4 µM and in addition an amplification of host response by titanized implant pockets.

5.
Arch Gynecol Obstet ; 292(4): 739-47, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25814297

ABSTRACT

Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.


Subject(s)
Breast Neoplasms/diagnosis , Contrast Media , Magnetic Resonance Imaging/methods , Mammography/methods , Breast Neoplasms/pathology , Female , Humans , Middle Aged , Radiation Dosage , Radiographic Image Enhancement