Cytometry A ; 93(12): 1246-1250, 2018 12.
Article in English | MEDLINE | ID: mdl-30369050

ABSTRACT

Circulating tumor cells (CTCs), epithelial-mesenchymal transition (EMT) cells, as well as a number of circulating cancer stromal cells (CStCs) are known to shed into the blood of cancer patients. Individually, and together, these cells provide biological and clinical information about the cancers. Filtration is a method used to isolate all of these cells, while eliminating red and white blood cells from whole peripheral blood. We have previously shown that accurate identification of these cell types is paramount to proper clinical assessment by describing the overlapping phenotypes of CTCs to one such CStC, the cancer-associated macrophage-like cell (CAML). We report that CAMLs possess a number of parallel applications to CTCs but have a broader range of clinical utility, including cancer screening, companion diagnostics, diagnosis, prognosis, monitoring of treatment response, and detection of recurrence. © 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of ISAC.


Subject(s)
Biopsy/methods , Blood Cells/pathology , Neoplasms/diagnosis , Neoplasms/pathology , Neoplastic Cells, Circulating/pathology , Cell Count/methods , Cell Separation/methods , Double-Blind Method , Early Detection of Cancer/methods , Epithelial-Mesenchymal Transition/physiology , Humans , Prognosis
2.
Methods Mol Biol ; 1572: 511-524, 2017.
Article in English | MEDLINE | ID: mdl-28299708

ABSTRACT

Filtration is one of the most efficient methods to remove red and white blood cells from whole blood, while retaining larger cells on the surface of the filter. Precision pore microfilters, such as the CellSieve™ microfilters, are ideally suited for this purpose, as they are strong, with uniform pore size and distribution, and have low fluorescent background required for microscopic image analysis. We present a system to implement the filtration of whole blood in combination with CellSieve™ microfilters that is simple and straightforward to use. Being that the blood of cancer patients often contains both tumor cells and stromal cells associated with cancer that are larger than normal blood cells, microfiltration shows great promise in better understanding these cell types. Accurate identification and characterization of cancer associated cells has led to increased specificity as it relates to CTCs and epithelial-mesenchymal transition cells (EMTs) and enabled the identification of previously unknown cell types, such as cancer associated macrophage-like cells (CAMLs). Using a system that isolates both CTCs and circulating stromal cells, clinicians can better diagnose cancer patients to determine therapy, monitor treatment, and watch for recurrence.


Subject(s)
Filtration/methods , Liquid Biopsy/methods , Neoplastic Cells, Circulating , Biomarkers , Early Detection of Cancer , Equipment Design , Filtration/instrumentation , Fluorescent Antibody Technique/methods , Humans , Liquid Biopsy/instrumentation , Micropore Filters , Microscopy , Neoplasms/diagnosis , Neoplastic Cells, Circulating/metabolism , Neoplastic Cells, Circulating/pathology
3.
J Transl Med ; 14(1): 198, 2016 07 02.
Article in English | MEDLINE | ID: mdl-27369977

ABSTRACT

BACKGROUND: Cryopreserved peripheral blood mononuclear cells (PBMCs) are commonly collected in biobanks. However, little data exist regarding the preservation of tumor-associated cells in cryopreserved collections. The objective of this study was to determine the feasibility of using the CellSieve™ microfiltration assay for the isolation of circulating tumor cells (CTCs) and circulating cancer-associated macrophage-like cells (CAMLs) from cryopreserved PBMC samples. METHODS: Blood samples spiked with breast (MCF-7), prostate (PC-3), and renal (786-O) cancer cell lines were used to establish analytical accuracy, efficiency, and reproducibility after cryopreservation. The spiked samples were processed through Ficoll separation, and cryopreservation was followed by thawing and microfiltration. RESULTS: MCF-7 cells were successfully retrieved with recovery efficiencies of 90.5 % without cryopreservation and 87.8 and 89.0 %, respectively, on day 7 and day 66 following cryopreservation. The corresponding recovery efficiencies of PC-3 cells were 83.3 % without cryopreservation and 85.3 and 84.7 %, respectively, after cryopreservation. Recovery efficiencies of 786-O cells were 92.7 % without cryopreservation, and 82.7 and 81.3 %, respectively, after cryopreservation. The recovered cells retained the morphologic characteristics and immunohistochemical markers that had been observed before freezing. The protocols were further validated by quantitation of CAMLs in blood samples from two patients with renal cell carcinoma (RCC). The recovery rates of CTCs and CAMLs from cryopreserved samples were not statistically significant different (P > 0.05) from matched fresh samples. CONCLUSIONS: To our knowledge, this is the first report that CAMLs could be cryopreserved and analyzed after thawing with microfiltration technology. The application of microfiltration technology to cryopreserved samples will enable much greater retrospective study of cancer patients in relation to long-term outcomes.


Subject(s)
Cryopreservation , Leukocytes, Mononuclear/pathology , Neoplasms/blood , Neoplasms/pathology , Carcinoma, Renal Cell/pathology , Cell Line, Tumor , Frozen Sections , Humans , Image Processing, Computer-Assisted , Kidney Neoplasms/pathology , Macrophages/pathology , Neoplastic Cells, Circulating/pathology , Retrospective Studies
4.
Mater Sci Eng C Mater Biol Appl ; 66: 193-198, 2016 Sep 01.
Article in English | MEDLINE | ID: mdl-27207054

ABSTRACT

There is a critical need to improve the accuracy of drug screening and testing through the development of in vitro culture systems that more effectively mimic the in vivo environment. Surface topographical features on the nanoscale level, in short nanotopography, effect the cell growth patterns, and hence affect cell function in culture. We report the preliminary results on the fabrication, and subsequent cellular growth, of nanoscale surface topography on polymer microfilters using cell lines as a precursor to circulating tumor cells (CTCs). To create various nanoscale features on the microfilter surface, we used reactive ion etching (RIE) with and without an etching mask. An anodized aluminum oxide (AAO) membrane fabricated directly on the polymer surface served as an etching mask. Polymer filters with a variety of modified surfaces were used to compare the effects on the culture of cancer cell lines in blank culture wells, with untreated microfilters or with RIE-treated microfilters. We then report the differences of cell shape, phenotype and growth patterns of bladder and glioblastoma cancer cell lines after isolation on the various types of material modifications. Our data suggest that RIE modified polymer filters can isolate model cell lines while retaining ell viability, and that the RIE filter modification allows T24 monolayering cells to proliferate as a structured cluster.


Subject(s)
Nanostructures/chemistry , Neoplastic Cells, Circulating/metabolism , Polymers/chemistry , Aluminum Oxide/chemistry , Cell Line, Tumor , Cell Proliferation/drug effects , Humans , Microscopy, Electron, Scanning , Microscopy, Fluorescence , Surface Properties
5.
RSC Adv ; 9: 4334-4342, 2014.
Article in English | MEDLINE | ID: mdl-25614802

ABSTRACT

Circulating tumor cells (CTCs) disseminated into peripheral blood from a primary, or metastatic, tumor can be used for early detection, diagnosis and monitoring of solid malignancies. CTC isolation by size exclusion techniques have long interested researchers as a simple broad based approach, which is methodologically diverse for use in both genomic and protein detection platforms. Though a variety of these microfiltration systems are employed academically and commercially, the limited ability to easily alter microfilter designs has hindered the optimization for CTC capture. To overcome this problem, we studied a unique photo-definable material with a scalable and mass producible photolithographic fabrication method. We use this fabrication method to systematically study and optimize the parameters necessary for CTC isolation using a microfiltration approach, followed by a comparison to a "standard" filtration membrane. We demonstrate that properly designed microfilters can capture MCF-7 cancer cells at rate of 98 ± 2% if they consist of uniform patterned distributions, ≥160 000 pores, and 7 µm pore diameters.

6.
Leuk Lymphoma ; 54(3): 579-86, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22839722

ABSTRACT

Overexpression of zeta-chain-associated protein 70 (ZAP-70) was recently recognized as an independent prognostic marker for the aggressive form of chronic lymphocytic leukemia (CLL). The objective of this study was to demonstrate the feasibility and implementation of quantitative detection of ZAP-70 protein in B cells to clearly distinguish patients with CLL with the aggressive form of the disease. B cells were isolated from patient blood and lysed. Released ZAP-70 protein was detected using an immunomagnetic fluorescence assay. The assay protocol was developed using Jurkat cells and recombinant ZAP-70 (rZAP-70). The limit of detection was determined to be lower than 125 Jurkat cells and 39 pg of rZAP-70 protein. The signal response was linear over a wide dynamic range, from 125 to 40 000 Jurkat cells per test (R(2) = 0.9987) and from 0 to 40 000 pg rZAP-70 protein per test (R(2) = 0.9928). The results from 20 patients with CLL correlated strongly with flow cytometry analysis. Concordance between the two methods for positive and negative results was 100% (7/7) and 92% (12/13), respectively, while the overall concordance between the two methods was 95%. The assay reported here is a simple, reliable and reproducible method for quantitative detection of ZAP-70 in patient leukemic cells, without the need for cell fixation or permeabilization. The ZAP-70 signal was linear over a wide dynamic range, which we believe enables quantitative assessment of small changes in ZAP-70 expression over the course of the disease and in response to therapeutic intervention.


Subject(s)
B-Lymphocytes/metabolism , Leukemia, Lymphocytic, Chronic, B-Cell/metabolism , ZAP-70 Protein-Tyrosine Kinase/analysis , Flow Cytometry , Fluorescent Antibody Technique/methods , Humans , Immunomagnetic Separation/methods , Jurkat Cells , Leukemia, Lymphocytic, Chronic, B-Cell/genetics , Leukemia, Lymphocytic, Chronic, B-Cell/pathology , Reproducibility of Results , Reverse Transcriptase Polymerase Chain Reaction , ZAP-70 Protein-Tyrosine Kinase/genetics
7.
Biosens Bioelectron ; 30(1): 337-41, 2011 Dec 15.
Article in English | MEDLINE | ID: mdl-22005594

ABSTRACT

Conventional culture-based methods for detection of E. coli O157:H7 in foods and water sources are time-consuming, and results can be ambiguous, requiring further confirmation by biochemical testing and PCR. A rapid immunoassay prior to cultivation to identify presumptive positive sample would save considerable time and resources. Immunomagnetic separation (IMS) techniques are routinely used for isolation of E. coli O157:H7 from enriched food and water samples, typically in conjunction with cultural detection followed by biochemical and serological confirmation. In this study, we developed a new method that combines IMS with fluorescence immunoassay, termed immunomagnetic fluorescence assay (IMFA), for the detection of E. coli O157:H7. E. coli O157:H7 cells were first captured by anti-O157 antibody-coated magnetic beads and then recognized by a fluorescent detector antibody, forming an immunosandwich complex. This complex was subsequently dissociated for measurement of fluorescence intensity with Signalyte™-II spectrofluorometer. Experiments were conducted to evaluate both linearity and sensitivity of the assay. Capture efficiencies were greater than 98%, as determined by cultural plating and quantitative real-time PCR, when cell concentrations were <10(5) cells/mL. Capture efficiency decreased at higher cell concentrations, due to the limitation of bead binding capacity. At lower cell concentrations (10-10(4) cells/mL), the fluorescence intensity of dissociated Cy5 solution was highly correlated with E. coli 157:H7 cell concentrations. The detection limit was 10 CFU per mL of water. The assay can be completed in less than 3 h since enrichment is not required, as compared to existing techniques that typically require a 24 h incubation for pre-enrichment, followed by confirmatory tests.


Subject(s)
Bacterial Load/instrumentation , Biosensing Techniques/instrumentation , Escherichia coli O157/isolation & purification , Fluoroimmunoassay/instrumentation , Immunomagnetic Separation/instrumentation , Equipment Design , Equipment Failure Analysis
8.
Methods Mol Biol ; 503: 389-401, 2009.
Article in English | MEDLINE | ID: mdl-19151954

ABSTRACT

The Integrating Waveguide Biosensor was developed for rapid and sensitive detection of bacterial cells, spores, and toxins. A sandwich format of immunoassay was employed using Salmonella as model. The analyte was immunocaptured on the inner surface of the waveguide and then detected by the antibody conjugated with fluorescent dye. The waveguide was illuminated by an excitation light at a 90 degrees angle. The emitted light from fluorescent labels on the surface of the waveguide was efficiently collected and channeled to a detector at the end of the waveguide, while minimizing interference from the excitation light. Utilizing fluorescent dye Cy5, a 635-nm diode laser for excitation, and a photomultiplier tube detector, the Integrating Waveguide Sensor System was able to detect approximately ten captured cells of Salmonella.


Subject(s)
Biosensing Techniques/instrumentation , Colony Count, Microbial/instrumentation , Optical Devices , Refractometry/instrumentation , Salmonella/isolation & purification , Spectrometry, Fluorescence/instrumentation , Biosensing Techniques/methods , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity , Systems Integration
9.
Methods Mol Biol ; 503: 423-34, 2009.
Article in English | MEDLINE | ID: mdl-19151956

ABSTRACT

A platform to detect multiplex fluorescent labels was developed based on liquid phase implementation of the Integrating Waveguide Sensor detection principles. The liquid sample is held in a capillary cuvette with a lens at one end. The excitation light incident on the cuvette at 90 degrees angle. The emitted fluorescence is efficiently gathered and propagated to the end of the waveguide cuvette, exiting via the lens to the detector. The capillary cuvette acts as a waveguide to efficiently gather the emission signal, providing high detection sensitivity for small sample sizes. Excitation sources ranging from 470 to 635 nm are four high-powered LEDs, allowing for multiplex fluorescence assays and a spectrometer is used to collect the signal from 390 to 790 nm. The cuvette can hold 1-35 microL samples. This technology can be used for a wide variety of assays and detection needs, such as FRET, end point PCR reading, immunoassays, chemiluminescence detection, multiplex quantum dots assays, polarization assays, etc.


Subject(s)
Biosensing Techniques/instrumentation , Electrophoresis, Microchip/instrumentation , Fiber Optic Technology/instrumentation , Flow Injection Analysis/instrumentation , Lighting/instrumentation , Spectrometry, Fluorescence/instrumentation , Biosensing Techniques/methods , Electrophoresis, Microchip/methods , Equipment Design , Equipment Failure Analysis , Flow Injection Analysis/methods , Lighting/methods , Reproducibility of Results , Sensitivity and Specificity , Systems Integration
10.
J Microbiol Methods ; 73(3): 242-6, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18395279

ABSTRACT

Bacillus anthracis is considered a major threat as an agent of bioterrorism. B. anthracis spores are readily dispersed as aerosols, are very persistent, and are resistant to normal disinfection treatments. Immunoassays have been developed to rapidly detect B. anthracis spores at high concentrations. However, detection of B. anthracis spores at lower concentrations is problematic due to the fact that closely related Bacillus species (e.g., B. thuringiensis) can cross-react with anti-B. anthracis antibodies, resulting in false positive detections. Subsequent polymerase chain reaction (PCR) analysis is required to differentiate virulent strains. We report here on a protocol for the rapid, sensitive detection of B. anthracis spore using the Integrating Waveguide Biosensor followed by a method for the rapid release and germination of immunocaptured spores. A detection limit of ca. 10(3) spores was achieved by incubating spores simultaneously with capture and detection antibodies ("liquid-phase" assay) prior to capture on capillary tubes/waveguides. Subsequent incubation with BHI broth directly in capillary tubes allowed for rapid germination, outgrowth, and release of spores, resulting in vegetative cells for PCR analysis.


Subject(s)
Bacillus anthracis/isolation & purification , Environmental Microbiology , Immunoassay/methods , Spores, Bacterial/isolation & purification , Biosensing Techniques , Sensitivity and Specificity