Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Breath Res ; 18(4)2024 Jul 17.
Article in English | MEDLINE | ID: mdl-38968933

ABSTRACT

Although the associations between a patient's body mass index (BMI) and metabolic diseases, as well as their breath test results, have been studied, the relationship between breath hydrogen/methane levels and metabolic diseases needs to be further clarified. We aimed to investigate how the composition of exhaled breath gases relates to metabolic disorders, such as diabetes mellitus, dyslipidemia, hypertension, and nonalcoholic fatty liver disease (NAFLD), and their key risk factors. An analysis was performed using the medical records, including the lactulose breath test (LBT) data of patients who visited the Ajou University Medical Center, Suwon, Republic of Korea, between January 2016 and December 2021. The patients were grouped according to four different criteria for LBT hydrogen and methane levels. Of 441 patients, 325 (72.1%) had positive results for methane only (hydrogen < 20 parts per million [ppm] and methane ⩾ 3 ppm). BMIs and NAFLD prevalence were higher in patients with only methane positivity than in patients with hydrogen and methane positivity (hydrogen ⩾ 20 ppm and methane ⩾ 3 ppm). According to a multivariate analysis, the odds ratio of only methane positivity was 2.002 (95% confidence interval [CI]: 1.244-3.221,P= 0.004) for NAFLD. Our results demonstrate that breath methane positivity is related to NAFLD and suggest that increased methane gas on the breath tests has the potential to be an easily measurable biomarker for NAFLD diagnosis.


Subject(s)
Breath Tests , Methane , Non-alcoholic Fatty Liver Disease , Humans , Breath Tests/methods , Non-alcoholic Fatty Liver Disease/metabolism , Non-alcoholic Fatty Liver Disease/diagnosis , Methane/analysis , Female , Male , Middle Aged , Republic of Korea/epidemiology , Adult , Body Mass Index , Hydrogen/analysis , Aged , Risk Factors , Exhalation
2.
J Hazard Mater ; 412: 125219, 2021 06 15.
Article in English | MEDLINE | ID: mdl-33516114

ABSTRACT

Capturing virus aerosols in a small volume of liquid is essential when monitoring airborne viruses. As such, aerosol-to-hydrosol enrichment is required to produce a detectable viral sample for real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR) assays. To meet this requirement, the efficient and non-destructive collection of airborne virus particles is needed, while the incoming air flow rate should be sufficiently high to quickly collect a large number of virus particles. To achieve this, we introduced a high air flow-rate electrostatic sampler (HAFES) that collected virus aerosols (human coronavirus 229E, influenza A virus subtypes H1N1 and H3N2, and bacteriophage MS2) in a continuously flowing liquid. Viral collection efficiency was evaluated using aerosol particle counts, while viral recovery rates were assessed using real-time qRT-PCR and plaque assays. An air sampling period of 20 min was sufficient to produce a sample suitable for use in real-time qRT-PCR in a viral epidemic scenario.


Subject(s)
Coronavirus , Influenza A Virus, H1N1 Subtype , Aerosols , Air Microbiology , Coronavirus/genetics , Humans , Influenza A Virus, H1N1 Subtype/genetics , Influenza A Virus, H3N2 Subtype , Static Electricity
3.
Biosens Bioelectron ; 170: 112656, 2020 Dec 15.
Article in English | MEDLINE | ID: mdl-33010706

ABSTRACT

Point-of-care risk assessment (PCRA) for airborne viruses requires a system that can enrich low-concentration airborne viruses dispersed in field environments into a small volume of liquid. In this study, airborne virus particles were collected to a degree above the limit of detection (LOD) for a real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR). This study employed an electrostatic air sampler to capture aerosolized test viruses (human coronavirus 229E (HCoV-229E), influenza A virus subtype H1N1 (A/H1N1), and influenza A virus subtype H3N2 (A/H3N2)) in a continuously flowing liquid (aerosol-to-hydrosol (ATH) enrichment) and a concanavalin A (ConA)-coated magnetic particles (CMPs)-installed fluidic channel for simultaneous hydrosol-to-hydrosol (HTH) enrichment. The air sampler's ATH enrichment capacity (EC) was evaluated using the aerosol counting method. In contrast, the HTH EC for the ATH-collected sample was evaluated using transmission-electron-microscopy (TEM)-based image analysis and real-time qRT-PCR assay. For example, the ATH EC for HCoV-229E was up to 67,000, resulting in a viral concentration of 0.08 PFU/mL (in a liquid sample) for a viral epidemic scenario of 1.2 PFU/m3 (in air). The real-time qRT-PCR assay result for this liquid sample was "non-detectable" however, subsequent HTH enrichment for 10 min caused the "non-detectable" sample to become "detectable" (cycle threshold (CT) value of 33.8 ± 0.06).


Subject(s)
Biosensing Techniques/instrumentation , Coronavirus 229E, Human/isolation & purification , Coronavirus Infections/virology , Influenza A Virus, H1N1 Subtype/isolation & purification , Influenza A Virus, H3N2 Subtype/isolation & purification , Influenza, Human/virology , Aerosols/analysis , Air Microbiology , Biosensing Techniques/economics , Coronavirus 229E, Human/genetics , Environmental Monitoring/economics , Environmental Monitoring/instrumentation , Equipment Design , Humans , Influenza A Virus, H1N1 Subtype/genetics , Influenza A Virus, H3N2 Subtype/genetics , Reverse Transcriptase Polymerase Chain Reaction/instrumentation , Time Factors
4.
ACS Sens ; 5(9): 2763-2771, 2020 09 25.
Article in English | MEDLINE | ID: mdl-32493010

ABSTRACT

Rapid monitoring of biological particulate matter (Bio-PM, bioaerosols) requires an enrichment technique for concentrating the Bio-PM dispersed in the air into a small volume of liquid. In this study, an electrostatic air sampler is employed to capture aerosolized test bacteria in a carrier liquid (aerosol-to-hydrosol (ATH) enrichment). Simultaneously, the captured bacteria are carried into a fluid channel for hydrosol-to-hydrosol (HTH) enrichment with Concanavalin A coated magnetic particles (CMPs). The ATH enrichment capacity of the air sampler was evaluated with an aerosol particle counter for the following test bacteria: Staphylococcus aureus, Bacillus cereus, Escherichia coli, and Acinetobacter baumannii. Then, the HTH enrichment capacity for the ATH-collected sample was evaluated using the colony-counting method, scanning electron microscopy based image analysis, fluorescence microscopy, electrical current measurements, and real-time quantitative polymerase chain reaction (qPCR). The ATH and HTH enrichment capacities for the given operation conditions were up to 80 000 and 14.9, respectively, resulting in a total enrichment capacity of up to 1.192 × 106. Given that air-to-liquid enrichment required to prepare detectable bacterial samples for real-time qPCR in field environments is of the order of at least 106, our method can be used to prepare a detectable sample from low-concentration airborne bacteria in the field and significantly reduce the time required for Bio-PM monitoring because of its enrichment capacity.


Subject(s)
Air Microbiology , Environmental Monitoring , Aerosols , Bacteria , Particulate Matter/analysis
5.
J Hazard Mater ; 396: 122640, 2020 09 05.
Article in English | MEDLINE | ID: mdl-32339873

ABSTRACT

Recently, various studies have reported the prevention and treatment of respiratory infection outbreaks caused by lethal viruses. Consequently, a variety of air filters coated with antimicrobial agents have been developed to capture and inactivate virus particles in continuous airflow conditions. However, since aerosolized infectious viral-testing is inadvisable due to safety concerns, their anti-viral capability has only been tested by inserting the filters into liquid media, where infectious virus particles disperse. In this study a novel method of determining anti-viral performance of an air filter against airborne infectious viruses is presented. Initially, anti-viral air filter tests were conducted. Firstly, by an air-media test, in which the air filter was placed against an aerosolized non-infectious virus. Secondly, by a liquid-media test, in which the filter was inserted into a liquid medium containing a non-infectious virus. Subsequently, a correlation was established by comparing the susceptibility constants obtained between the two medium tests and an association was found for the air medium test with infectious virus. After ensuring the relationship did not depend on the virus species, the correlation was used to derive the results of the air-medium test from the results of the liquid-medium test.


Subject(s)
Air Filters , Anti-Infective Agents , Viruses , Air Microbiology , Antiviral Agents , Filtration
6.
J Hazard Mater ; 369: 684-690, 2019 05 05.
Article in English | MEDLINE | ID: mdl-30826561

ABSTRACT

Simultaneous improvement in detection speed and reliability is critical for bioaerosol monitoring. Recent rapid detection strategies exhibit difficulties with misinterpretation due to signal interference from co-existing nonbiological particles, whereas biomolecular and bioluminescent approaches require long process times (>several tens of minutes) to generate readable values despite their better detection reliability. To overcome these shortcomings, we designed a system to achieve rapid reliable field detection of bioaerosols (>104 relative luminescence units [RLU] per cubic meter of air) in <3 min processing time (equivalent to 24 L sampling air volume) by employing a lysis droplet supply for efficient extraction of adenosine triphosphate (ATP) from particulate matter (PM) and a photomultiplier tube detector for signal amplification of ATP bioluminescence. We also suggested the use of the ratio of RLU (m-3) to total PM (µg m-3), or specific bioluminescence (RLU µg-1), as a measure of the biofraction of PM (i.e., potential biohazards). A correlation between RLU and colony forming unit was also obtained from simultaneous aerosol sampling using an agar-inserted sampler.


Subject(s)
Adenosine Triphosphate/analysis , Dust/analysis , Environmental Monitoring/methods , Particulate Matter/analysis , Aerosols , Air Microbiology , Colony-Forming Units Assay , Computer Systems , Particle Size , Reproducibility of Results , Staphylococcus aureus/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...