Clin Exp Otorhinolaryngol ; 5 Suppl 1: S19-23, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22701769

ABSTRACT

OBJECTIVES: In this study, we compared the magnetic resonance (MR) image artifacts caused by a conventional metal-based cochlear implant and a newly developed liquid crystal polymer (LCP)-based device. METHODS: The metal-based cochlear implant system (Nurobiosys Co.) was attached to side of the head of a subject and the LCP-based device was attached to opposite side. In both devices, alignment magnets were removed for safety. Magnetic resonance imaging (MRI) was performed on a widely used 3.0 T and an ultra-high 7.0 T MRI machine. 3.0 and 7.0 T MR images were acquired using T1- and T2(*)-weighted gradient echo sequences, respectively. RESULTS: In the 3.0 T images, the metal-based device on the left side generated the significant amount of artifacts. The MR images in the proximity of the metal package were obscured by the artifacts in both axial and sagittal views. On the other hand, the MR images near the LCP-based device were relatively free from the artifacts and clearly showed the brain structures. 7.0 T MR images showed the more severe distortion in the both sides but the metal-based cochlear implant system caused a much larger obscure area than the LCP-based system. CONCLUSION: The novel LCP-based cochlear implant provides a good MRI compatibility beyond present-day cochlear implants. Thus, MR images can be obtained from the subjects even with the implanted LCP-based neural prosthetic systems providing useful diagnostic information. Furthermore, it will be also useful for functional MRI studies of the auditory perception mechanism after cochlear implantations as well as for positron emission tomography-MRI hybrid imaging.

2.
IEEE Trans Biomed Eng ; 54(6 Pt 1): 973-82, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17554817

ABSTRACT

A simplified cochlear implant (CI) system would be appropriate for widespread use in developing countries. Here, we describe a CI that we have designed to realize such a concept. The system implements 8 channels of processing and stimulation using the continuous interleaved sampling (CIS) strategy. A generic digital signal processing (DSP) chip is used for the processing, and the filtering functions are performed with a fast Fourier transform (FFT) of a microphone or other input. Data derived from the processing are transmitted through an inductive link using pulse width modulation (PWM) encoding and amplitude shift keying (ASK) modulation. The same link is used in the reverse direction for backward telemetry of electrode and system information. A custom receiver-stimulator chip has been developed that demodulates incoming data using pulse counting and produces charge balanced biphasic pulses at 1000 pulses/s/electrode. This chip is encased in a titanium package that is hermetically sealed using a simple but effective method. A low cost metal-silicon hybrid mold has been developed for fabricating an intracochlear electrode array with 16 ball-shaped stimulating contacts.


Subject(s)
Cochlear Implants , Electric Stimulation Therapy/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Speech Recognition Software , Therapy, Computer-Assisted/instrumentation , Electric Stimulation Therapy/methods , Equipment Design , Equipment Failure Analysis , Miniaturization , Therapy, Computer-Assisted/methods