Opt Lett ; 49(11): 3247-3250, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38824375

ABSTRACT

Spatial, temporal, and spectral resolutions and field-of-view are important characteristics of any imaging system. In most, if not all, it is impossible to change the above characteristics after recording a digital picture, video, or hologram. In recent years, there have been investigations on the possibilities to change the above characteristics post-recording. In this Letter, for the first time, to the best of our knowledge, we report novel recording and reconstruction methods built upon the principles of coded aperture imaging that allow changing the axial and spectral resolutions post-recording. We named this method-post-ensemble generation with Airy beams for spatial and spectral switching (PEGASASS). In PEGASASS, light from an object point is converted into Airy beams and recorded such that every recording has a unique Airy pattern. An ensemble of Airy patterns is constructed post-recording and the axial and spectral resolutions are tuned by controlling the chaos in the ensemble. The above tunability is achieved without adversely affecting the lateral resolution. Proof-of-concept experimental results of PEGASASS in 3D in both (x,y,z) and (x,y,λ) and 4D in (x,y,z,λ) are presented. We believe that PEGASASS has the potential to revolutionize the field of imaging and holography.

2.
Micromachines (Basel) ; 15(6)2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38930764

ABSTRACT

Polarimetry is used to determine the Stokes parameters of a laser beam. Once all four S0,1,2,3 parameters are determined, the state of polarisation is established. Upon reflection of a laser beam with the defined S polarisation state, the directly measured S parameters can be used to determine the optical properties of the surface, which modify the S-state upon reflection. Here, we use polarimetry for the determination of surface anisotropies related to the birefringence and dichroism of different materials, which have a common feature of linear patterns with different alignments and scales. It is shown that polarimetry in the back-reflected light is complementary to ellipsometry and four-polarisation camera imaging; experiments were carried out using a microscope.

3.
Micromachines (Basel) ; 15(4)2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38675348

ABSTRACT

Axial resolution is one of the most important characteristics of a microscope. In all microscopes, a high axial resolution is desired in order to discriminate information efficiently along the longitudinal direction. However, when studying thick samples that do not contain laterally overlapping information, a low axial resolution is desirable, as information from multiple planes can be recorded simultaneously from a single camera shot instead of plane-by-plane mechanical refocusing. In this study, we increased the focal depth of an infrared microscope non-invasively by introducing a binary axicon fabricated on a barium fluoride substrate close to the sample. Preliminary results of imaging the thick and sparse silk fibers showed an improved focal depth with a slight decrease in lateral resolution and an increase in background noise.

4.
Nanomaterials (Basel) ; 14(3)2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38334558

ABSTRACT

Emerging applications of optical technologies are driving the development of miniaturised light sources, which in turn require the fabrication of matching micro-optical elements with sub-1 mm cross-sections and high optical quality. This is particularly challenging for spatially constrained biomedical applications where reduced dimensionality is required, such as endoscopy, optogenetics, or optical implants. Planarisation of a lens by the Fresnel lens approach was adapted for a conical lens (axicon) and was made by direct femtosecond 780 nm/100 fs laser writing in the SZ2080™ polymer with a photo-initiator. Optical characterisation of the positive and negative fraxicons is presented. Numerical modelling of fraxicon optical performance under illumination by incoherent and spatially extended light sources is compared with the ideal case of plane-wave illumination. Considering the potential for rapid replication in soft polymers and resists, this approach holds great promise for the most demanding technological applications.

5.
Opt Express ; 32(1): 1034-1046, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38175119

ABSTRACT

Recovering original images from blurred images is a challenging task. We propose a new deconvolution method termed incoherent nonlinear deconvolution using an iterative algorithm (INDIA). Two inputs are introduced into the algorithm: one is a random or engineered point spread function of the scattering system, and the other is a blurred or distorted image of some object produced from this system. The two functions are Fourier transformed, and their phase distributions are processed independently of their magnitude. The algorithm yields the image of the original object with reduced blurring effects. The results of the new method are compared to two linear and two nonlinear algorithms under various types of blurs. The root mean square error and structural similarity between the original and recovered images are chosen as the comparison criteria between the five different algorithms. The simulation and experimental results confirm the superior performance of INDIA compared to the other tested deblurring methods.

6.
Opt Express ; 31(16): 26120-26134, 2023 Jul 31.
Article in English | MEDLINE | ID: mdl-37710480

ABSTRACT

Interferenceless coded aperture correlation holography (I-COACH) is one of the simplest incoherent holography techniques. In I-COACH, the light from an object is modulated by a coded mask, and the resulting intensity distribution is recorded. The 3D image of the object is reconstructed by processing the object intensity distribution with the pre-recorded 3D point spread intensity distributions. The first version of I-COACH was implemented using a scattering phase mask, which makes its implementation challenging in light-sensitive experiments. The I-COACH technique gradually evolved with the advancement in the engineering of coded phase masks that retain randomness but improve the concentration of light in smaller areas in the image sensor. In this direction, I-COACH was demonstrated using weakly scattered intensity patterns, dot patterns and recently using accelerating Airy patterns, and the case with accelerating Airy patterns exhibited the highest SNR. In this study, we propose and demonstrate I-COACH with an ensemble of self-rotating beams. Unlike accelerating Airy beams, self-rotating beams exhibit a better energy concentration. In the case of self-rotating beams, the uniqueness of the intensity distributions with depth is attributed to the rotation of the intensity pattern as opposed to the shifts of the Airy patterns, making the intensity distribution stable along depths. A significant improvement in SNR was observed in optical experiments.

7.
Article in English | MEDLINE | ID: mdl-37282572

ABSTRACT

BACKGROUND: Evidence of type 2 diabetes mellitus (T2DM) associated with hippocampal atrophy is reported by researchers all around the globe. The majority of such studies were conducted among the geriatric and elderly populations with other substantial co-morbid diseases. Hence, the present study aims to evaluate the hippocampal volume of T2DM subjects below 60 years without any concomitant disorders and assess the declarative memory. MATERIALS AND METHODS: The cross-sectional observational study was conducted among the ethnic population of Manipur. A total of 17 T2DM subjects and 17 healthy controls, who are apparently healthy, matched by age, sex, and comparable education, were enrolled in the study. Magnetic Resonance Imaging (MRI) of high-resolution sagittal structural T1-weighted anatomical sequence was acquired using a three-dimension magnetization-prepared rapid-acquisition gradient echo (MPRAGE). The hippocampus volume was measured using the volBrain Automated MRI Brain Volumetry System. Declarative memory was estimated by the Rey Auditory Verbal Learning Test (RAVLT). RESULTS: No statistically significant differences were found in hippocampal volume, and RAVLT scores between T2DM subjects, and healthy controls group (P > 0.05). CONCLUSIONS: The study data indicates that there is no particular hippocampal volume vulnerability in T2DM participants within the ethnic population of Manipur.

8.
Sci Rep ; 13(1): 7390, 2023 May 06.
Article in English | MEDLINE | ID: mdl-37149707

ABSTRACT

Fresnel incoherent correlation holography (FINCH) is a well-established incoherent digital holography technique. In FINCH, light from an object point splits into two, differently modulated using two diffractive lenses with different focal distances and interfered to form a self-interference hologram. The hologram numerically back propagates to reconstruct the image of the object at different depths. FINCH, in the inline configuration, requires at least three camera shots with different phase shifts between the two interfering beams followed by superposition to obtain a complex hologram that can be used to reconstruct an object's image without the twin image and bias terms. In general, FINCH is implemented using an active device, such as a spatial light modulator, to display the diffractive lenses. The first version of FINCH used a phase mask generated by random multiplexing of two diffractive lenses, which resulted in high reconstruction noise. Therefore, a polarization multiplexing method was later developed to suppress the reconstruction noise at the expense of some power loss. In this study, a novel computational algorithm based on the Gerchberg-Saxton algorithm (GSA) called transport of amplitude into phase (TAP-GSA) was developed for FINCH to design multiplexed phase masks with high light throughput and low reconstruction noise. The simulation and optical experiments demonstrate a power efficiency improvement of ~ 150 and ~ 200% in the new method in comparison to random multiplexing and polarization multiplexing, respectively. The SNR of the proposed method is better than that of random multiplexing in all tested cases but lower than that of the polarization multiplexing method.

9.
Materials (Basel) ; 16(5)2023 Feb 25.
Article in English | MEDLINE | ID: mdl-36903030

ABSTRACT

Ultra-short 230 fs laser pulses of 515 nm wavelength were tightly focused into 700 nm focal spots and utilised in opening ∼400 nm nano-holes in a Cr etch mask that was tens-of-nm thick. The ablation threshold was found to be 2.3 nJ/pulse, double that of plain silicon. Nano-holes irradiated with pulse energies below this threshold produced nano-disks, while higher energies produced nano-rings. Both these structures were not removed by either Cr or Si etch solutions. Subtle sub-1 nJ pulse energy control was harnessed to pattern large surface areas with controlled nano-alloying of Si and Cr. This work demonstrates vacuum-free large area patterning of nanolayers by alloying them at distinct locations with sub-diffraction resolution. Such metal masks with nano-hole opening can be used for formation of random patterns of nano-needles with sub-100 nm separation when applied to dry etching of Si.

10.
Sci Rep ; 13(1): 2996, 2023 Feb 21.
Article in English | MEDLINE | ID: mdl-36810914

ABSTRACT

Interferenceless coded aperture correlation holography (I-COACH) techniques have revolutionized the field of incoherent imaging, offering multidimensional imaging capabilities with a high temporal resolution in a simple optical configuration and at a low cost. The I-COACH method uses phase modulators (PMs) between the object and the image sensor, which encode the 3D location information of a point into a unique spatial intensity distribution. The system usually requires a one-time calibration procedure in which the point spread functions (PSFs) at different depths and/or wavelengths are recorded. When an object is recorded under identical conditions as the PSF, the multidimensional image of the object is reconstructed by processing the object intensity with the PSFs. In the previous versions of I-COACH, the PM mapped every object point to a scattered intensity distribution or random dot array pattern. The scattered intensity distribution results in a low SNR compared to a direct imaging system due to optical power dilution. Due to the limited focal depth, the dot pattern reduces the imaging resolution beyond the depth of focus if further multiplexing of phase masks is not performed. In this study, I-COACH has been realized using a PM that maps every object point into a sparse random array of Airy beams. Airy beams during propagation exhibit a relatively high focal depth with sharp intensity maxima that shift laterally following a curved path in 3D space. Therefore, sparse, randomly distributed diverse Airy beams exhibit random shifts with respect to one another during propagation, generating unique intensity distributions at different distances while retaining optical power concentrations in small areas on the detector. The phase-only mask displayed on the modulator was designed by random phase multiplexing of Airy beam generators. The simulation and experimental results obtained for the proposed method are significantly better in SNR than in the previous versions of I-COACH.

11.
Biosensors (Basel) ; 12(12)2022 Nov 24.
Article in English | MEDLINE | ID: mdl-36551040

ABSTRACT

Phase imaging of biochemical samples has been demonstrated for the first time at the Infrared Microspectroscopy (IRM) beamline of the Australian Synchrotron using the usually discarded near-IR (NIR) region of the synchrotron-IR beam. The synchrotron-IR beam at the Australian Synchrotron IRM beamline has a unique fork shaped intensity distribution as a result of the gold coated extraction mirror shape, which includes a central slit for rejection of the intense X-ray beam. The resulting beam configuration makes any imaging task challenging. For intensity imaging, the fork shaped beam is usually tightly focused to a point on the sample plane followed by a pixel-by-pixel scanning approach to record the image. In this study, a pinhole was aligned with one of the lobes of the fork shaped beam and the Airy diffraction pattern was used to illuminate biochemical samples. The diffracted light from the samples was captured using a NIR sensitive lensless camera. A rapid phase-retrieval algorithm was applied to the recorded intensity distributions to reconstruct the phase information. The preliminary results are promising to develop multimodal imaging capabilities at the IRM beamline of the Australian Synchrotron.


Subject(s)
Multimodal Imaging , Synchrotrons , Australia , Algorithms
12.
Micromachines (Basel) ; 13(8)2022 Aug 19.
Article in English | MEDLINE | ID: mdl-36014268

ABSTRACT

Speckle patterns are formed by random interferences of mutually coherent beams. While speckles are often considered as unwanted noise in many areas, they also formed the foundation for the development of numerous speckle-based imaging, holography, and sensing technologies. In the recent years, artificial speckle patterns have been generated with spatially incoherent sources using static and dynamic optical modulators for advanced imaging applications. In this report, a basic study has been carried out with Bessel distribution as the fundamental building block of the speckle pattern (i.e., speckle patterns formed by randomly interfering Bessel beams). In general, Bessel beams have a long focal depth, which in this scenario is counteracted by the increase in randomness enabling tunability of the axial resolution. As a direct imaging method could not be applied when there is more than one Bessel beam, an indirect computational imaging framework has been applied to study the imaging characteristics. This computational imaging process consists of three steps. In the first step, the point spread function (PSF) is calculated, which is the speckle pattern formed by the random interferences of Bessel beams. In the next step, the intensity distribution for an object is obtained by a convolution between the PSF and object function. The object information is reconstructed by processing the PSF and the object intensity distribution using non-linear reconstruction. In the computational imaging framework, the lateral resolution remained a constant, while the axial resolution improved when the randomness in the system was increased. Three-dimensional computational imaging with statistical averaging for different cases of randomness has been synthetically demonstrated for two test objects located at two different distances. The presented study will lead to a new generation of incoherent imaging technologies.

13.
Micromachines (Basel) ; 13(8)2022 Jul 25.
Article in English | MEDLINE | ID: mdl-35893168

ABSTRACT

THz band-pass filters were fabricated by femtosecond-laser ablation of 25-µm-thick micro-foils of stainless steel and Kapton film, which were subsequently metal coated with a ∼70 nm film, closely matching the skin depth at the used THz spectral window. Their spectral performance was tested in transmission and reflection modes at the Australian Synchrotron's THz beamline. A 25-µm-thick Kapton film performed as a Fabry-Pérot etalon with a free spectral range (FSR) of 119 cm-1, high finesse Fc≈17, and was tuneable over ∼10µm (at ∼5 THz band) with ß=30∘ tilt. The structure of the THz beam focal region as extracted by the first mirror (slit) showed a complex dependence of polarisation, wavelength and position across the beam. This is important for polarisation-sensitive measurements (in both transmission and reflection) and requires normalisation at each orientation of linear polarisation.

14.
Nanoscale Horiz ; 7(9): 1047-1053, 2022 Aug 22.
Article in English | MEDLINE | ID: mdl-35796230

ABSTRACT

Polarisation analysis of light-matter interactions established for propagating optical far-fields is now extended into an evanescent field as demonstrated in this study using an attenuated total reflection (ATR) setup and a synchrotron source at THz frequencies. Scalar intensity E2, rather than a vector E-field, is used for absorbance analysis of the s- and p-components of the linearly polarised incident light. Absorption and phase changes induced by the sample and detected at the transmission port of the ATR accessory revealed previously non-accessible anisotropy in the absorption-dispersion properties of the sample probed by the evanescent optical near-field. Mapping of the sample's anisotropy perpendicular to its surface by the non-propagating light field is validated and the cos2 θ absorbance dependence was observed for the angle θ, where θ = 0° is aligned with the sample's surface. A four-polarisation method is presented for the absorbance mapping and a complimentary retardance spectrum is retrieved from the same measurement of the angular dependence of transmittance in structurally complex poly-hydroxybutyrate (PHB) and poly-L-lactic acid (PLLA) samples with amorphous and banded-spherulite (radially isotropic) crystalline regions. A possibility of all 3D mapping of anisotropy (polarisation tomography) is outlined.

15.
J Imaging ; 8(6)2022 Jun 20.
Article in English | MEDLINE | ID: mdl-35735973

ABSTRACT

Indirect-imaging methods involve at least two steps, namely optical recording and computational reconstruction. The optical-recording process uses an optical modulator that transforms the light from the object into a typical intensity distribution. This distribution is numerically processed to reconstruct the object's image corresponding to different spatial and spectral dimensions. There have been numerous optical-modulation functions and reconstruction methods developed in the past few years for different applications. In most cases, a compatible pair of the optical-modulation function and reconstruction method gives optimal performance. A new reconstruction method, termed nonlinear reconstruction (NLR), was developed in 2017 to reconstruct the object image in the case of optical-scattering modulators. Over the years, it has been revealed that the NLR can reconstruct an object's image modulated by an axicons, bifocal lenses and even exotic spiral diffractive elements, which generate deterministic optical fields. Apparently, NLR seems to be a universal reconstruction method for indirect imaging. In this review, the performance of NLR isinvestigated for many deterministic and stochastic optical fields. Simulation and experimental results for different cases are presented and discussed.

16.
Nanoscale Res Lett ; 17(1): 37, 2022 Mar 24.
Article in English | MEDLINE | ID: mdl-35325325

ABSTRACT

In recent years, there has been a significant transformation in the field of incoherent imaging with new possibilities of compressing three-dimensional (3D) information into a two-dimensional intensity distribution without two-beam interference (TBI). Most incoherent 3D imagers without TBI are based on scattering by a random phase mask exhibiting sharp autocorrelation and low cross-correlation along the depth axis. Consequently, during reconstruction, high lateral and axial resolutions are obtained. Scattering based-Imaging requires a wasteful photon budget and is therefore precluded in many power-sensitive applications. This study develops a proof-of-concept 3D incoherent imaging method using a rotating point spread function termed 3D Incoherent Imaging with Spiral Beams (3DI2SB). The rotation speed of the point spread function (PSF) with displacement and the orbital angular momentum has been theoretically analyzed. The imaging characteristics of 3DI2SB were compared with a direct imaging system using a diffractive lens, and the proposed system exhibited a higher focal depth than the direct imaging system. Different computational reconstruction methods such as the Lucy-Richardson algorithm (LRA), non-linear reconstruction (NLR), and the Lucy-Richardson-Rosen algorithm (LRRA) were compared. While LRRA performed better than both LRA and NLR for an ideal case, NLR performed better than both under real experimental conditions. Both single plane imaging, as well as synthetic 3D imaging, were demonstrated. We believe that the proposed approach might cause a paradigm shift in the current state-of-the-art incoherent imaging, fluorescence microscopy, and astronomical imaging.

17.
J Imaging ; 7(12)2021 Nov 26.
Article in English | MEDLINE | ID: mdl-34940719

ABSTRACT

Quantitative Phase Imaging (QPI) provides unique means for the imaging of biological or technical microstructures, merging beneficial features identified with microscopy, interferometry, holography, and numerical computations. This roadmap article reviews several digital holography-based QPI approaches developed by prominent research groups. It also briefly discusses the present and future perspectives of 2D and 3D QPI research based on digital holographic microscopy, holographic tomography, and their applications.

18.
Nanomaterials (Basel) ; 11(12)2021 Nov 29.
Article in English | MEDLINE | ID: mdl-34947596

ABSTRACT

Polarisation analysis in the mid-infrared fingerprint region was carried out on thin (∼1 µm) Si and SiO2 films evaporated via glancing angle deposition (GLAD) method at 70∘ to the normal. Synchrotron-based infrared microspectroscopic measurements were carried out on the Infrared Microspectroscopy (IRM) beamline at Australian Synchrotron. Specific absorption bands, particularly Si-O-Si stretching vibration, was found to follow the angular dependence of ∼cos2θ, consistent with the absorption anisotropy. This unexpected anisotropy stems from the enhanced absorption in nano-crevices, which have orientation following the cos2θ angular dependence as revealed by Fourier transforming the image of the surface of 3D columnar films and numerical modeling of light field enhancement by sub-wavelength nano-crevices.

19.
J Imaging ; 7(10)2021 Sep 29.
Article in English | MEDLINE | ID: mdl-34677283

ABSTRACT

Fresnel incoherent correlation holography (FINCH) was a milestone in incoherent holography. In this roadmap, two pathways, namely the development of FINCH and applications of FINCH explored by many prominent research groups, are discussed. The current state-of-the-art FINCH technology, challenges, and future perspectives of FINCH technology as recognized by a diverse group of researchers contributing to different facets of research in FINCH have been presented.

20.
J Synchrotron Radiat ; 28(Pt 5): 1616-1619, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-34475308

ABSTRACT

The Infrared Microspectroscopy Beamline at the Australian Synchrotron is equipped with a Fourier transform infrared (FTIR) spectrometer, which is coupled with an infrared (IR) microscope and a choice of two detectors: a single-point narrow-band mercury cadmium telluride (MCT) detector and a 64 × 64 multi-pixel focal plane array (FPA) imaging detector. A scanning-based point-by-point mapping method is commonly used with a tightly focused synchrotron IR beam at the sample plane, using an MCT detector and a matching 36× IR reflecting objective and condenser (NA = 0.5), which is time consuming. In this study, the beam size at the sample plane was increased using a 15× objective and the spatio-spectral aberrations were investigated. A correlation-based semi-synthetic computational optical approach was applied to assess the possibilities of exploiting the aberrations to perform rapid imaging rather than a mapping approach.