1.
J Occup Environ Hyg ; 19(5): 281-294, 2022 05.
Article in English | MEDLINE | ID: mdl-35289720

ABSTRACT

Dental personnel are ranked among the highest risk occupations for exposure to SARS-CoV-2 due to their close proximity to the patient's mouth and many aerosol generating procedures encountered in dental practice. One method to reduce aerosols in dental settings is the use of intraoral evacuation systems. Intraoral evacuation systems are placed directly into a patient's mouth and maintain a dry field during procedures by capturing liquid and aerosols. Although multiple intraoral dental evacuation systems are commercially available, the efficacy of these systems is not well understood. The objectives of this study were to evaluate the efficacy of four dental evacuation systems at mitigating aerosol exposures during simulated ultrasonic scaling and crown preparation procedures. We conducted real-time respirable (PM4) and thoracic (PM10) aerosol sampling during ultrasonic scaling and crown preparation procedures while using four commercially available evacuation systems: a high-volume evacuator (HVE) and three alternative intraoral systems (A, B, C). Four trials were conducted for each system. Respirable and thoracic mass concentrations were measured during procedures at three locations including (1) near the breathing zone (BZ) of the dentist, (2) edge of the dental operatory room approximately 0.9 m away from the mannequin mouth, and (3) hallway supply cabinet located approximately 1.5 m away from the mannequin mouth. Respirable and thoracic mass concentrations measured during each procedure were compared with background concentrations measured in each respective location. Use of System A or HVE reduced thoracic (System A) and respirable (HVE) mass concentrations near the dentist's BZ to median background concentrations most often during the ultrasonic scaling procedure. During the crown preparation, use of System B or HVE reduced thoracic (System B) and respirable (HVE or System B) near the dentist's BZ to median background concentrations most often. Although some differences in efficacy were noted during each procedure and aerosol size fraction, the difference in median mass concentrations among evacuation systems was minimal, ranging from 0.01 to 1.48 µg/m3 across both procedures and aerosol size fractions.


Subject(s)
COVID-19 , SARS-CoV-2 , Aerosols , COVID-19/prevention & control , Dental Clinics , Humans , Specimen Handling
2.
J Occup Environ Hyg ; 12(4): 245-55, 2015.
Article in English | MEDLINE | ID: mdl-25438035

ABSTRACT

Computational fluid dynamics (CFD) modeling was performed to investigate the aspiration efficiency of the human head in low velocities to examine whether the current inhaled particulate mass (IPM) sampling criterion matches the aspiration efficiency of an inhaling human in airflows common to worker exposures. Data from both mouth and nose inhalation, averaged to assess omnidirectional aspiration efficiencies, were compiled and used to generate a unifying model to relate particle size to aspiration efficiency of the human head. Multiple linear regression was used to generate an empirical model to estimate human aspiration efficiency and included particle size as well as breathing and freestream velocities as dependent variables. A new set of simulated mouth and nose breathing aspiration efficiencies was generated and used to test the fit of empirical models. Further, empirical relationships between test conditions and CFD estimates of aspiration were compared to experimental data from mannequin studies, including both calm-air and ultra-low velocity experiments. While a linear relationship between particle size and aspiration is reported in calm air studies, the CFD simulations identified a more reasonable fit using the square of particle aerodynamic diameter, which better addressed the shape of the efficiency curve's decline toward zero for large particles. The ultimate goal of this work was to develop an empirical model that incorporates real-world variations in critical factors associated with particle aspiration to inform low-velocity modifications to the inhalable particle sampling criterion.


Subject(s)
Air Pollutants, Occupational/analysis , Computer Simulation , Inhalation Exposure/statistics & numerical data , Inhalation , Air Movements , Environmental Monitoring/methods , Humans , Hydrodynamics , Inhalation Exposure/analysis , Linear Models , Mouth , Nose , Particle Size
3.
Ann Occup Hyg ; 58(5): 625-45, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24665111

ABSTRACT

An understanding of how particles are inhaled into the human nose is important for developing samplers that measure biologically relevant estimates of exposure in the workplace. While previous computational mouth-breathing investigations of particle aspiration have been conducted in slow moving air, nose breathing still required exploration. Computational fluid dynamics was used to estimate nasal aspiration efficiency for an inhaling humanoid form in low velocity wind speeds (0.1-0.4 m s(-1)). Breathing was simplified as continuous inhalation through the nose. Fluid flow and particle trajectories were simulated over seven discrete orientations relative to the oncoming wind (0, 15, 30, 60, 90, 135, 180°). Sensitivities of the model simplification and methods were assessed, particularly the placement of the recessed nostril surface and the size of the nose. Simulations identified higher aspiration (13% on average) when compared to published experimental wind tunnel data. Significant differences in aspiration were identified between nose geometry, with the smaller nose aspirating an average of 8.6% more than the larger nose. Differences in fluid flow solution methods accounted for 2% average differences, on the order of methodological uncertainty. Similar trends to mouth-breathing simulations were observed including increasing aspiration efficiency with decreasing freestream velocity and decreasing aspiration with increasing rotation away from the oncoming wind. These models indicate nasal aspiration in slow moving air occurs only for particles <100 µm.


Subject(s)
Air Pollutants, Occupational/analysis , Computer Simulation , Hydrodynamics , Inhalation Exposure/analysis , Inhalation , Air Movements , Environmental Monitoring/methods , Humans , Manikins , Nose
4.
Ann Occup Hyg ; 57(6): 740-57, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23316076

ABSTRACT

Computational fluid dynamics was used to investigate particle aspiration efficiency in low-moving air typical of occupational settings (0.1-0.4 m s(-1)). Fluid flow surrounding an inhaling humanoid form and particle trajectories traveling into the mouth were simulated for seven discrete orientations relative to the oncoming wind (0°, 15°, 30°, 60°, 90°, 135° and 180°). Three continuous inhalation velocities (1.81, 4.33, and 12.11 m s(-1)), representing the mean inhalation velocity associated with sinusoidal at-rest, moderate, and heavy breathing (7.5, 20.8, and 50.3 l min(-1), respectively) were simulated. These simulations identified a decrease in aspiration efficiency below the inhalable particulate mass (IPM) criterion of 0.5 for large particles, with no aspiration of particles 100 µm and larger for at-rest breathing and no aspiration of particles 116 µm for moderate breathing, over all freestream velocities and orientations relative to the wind. For particles smaller than 100 µm, orientation-averaged aspiration efficiency exceeded the IPM criterion, with increased aspiration efficiency as freestream velocity decreased. Variability in aspiration efficiencies between velocities was low for small (<22 µm) particles, but increased with increasing particle size over the range of conditions studied. Orientation-averaged simulation estimates of aspiration efficiency agree with the linear form of the proposed linear low-velocity inhalable convention through 100 µm, based on laboratory studies using human mannequins.


Subject(s)
Air Pollutants, Occupational/analysis , Computer Simulation , Hydrodynamics , Mouth Breathing , Air Movements , Air Pollutants, Occupational/adverse effects , Environmental Monitoring/methods , Humans , Inhalation Exposure/adverse effects , Inhalation Exposure/analysis , Manikins , Orientation , Particle Size
5.
Ann Occup Hyg ; 57(2): 184-99, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23006817

ABSTRACT

Computational fluid dynamics (CFD) has been used to report particle inhalability in low velocity freestreams, where realistic faces but simplified, truncated, and cylindrical human torsos were used. When compared to wind tunnel velocity studies, the truncated models were found to underestimate the air's upward velocity near the humans, raising questions about aspiration estimation. This work compares aspiration efficiencies for particles ranging from 7 to 116 µm using three torso geometries: (i) a simplified truncated cylinder, (ii) a non-truncated cylinder, and (iii) an anthropometrically realistic humanoid body. The primary aim of this work is to (i) quantify the errors introduced by using a simplified geometry and (ii) determine the required level of detail to adequately represent a human form in CFD studies of aspiration efficiency. Fluid simulations used the standard k-epsilon turbulence models, with freestream velocities at 0.1, 0.2, and 0.4 m s(-1) and breathing velocities at 1.81 and 12.11 m s(-1) to represent at-rest and heavy breathing rates, respectively. Laminar particle trajectory simulations were used to determine the upstream area, also known as the critical area, where particles would be inhaled. These areas were used to compute aspiration efficiencies for facing the wind. Significant differences were found in both vertical velocity estimates and the location of the critical area between the three models. However, differences in aspiration efficiencies between the three forms were <8.8% over all particle sizes, indicating that there is little difference in aspiration efficiency between torso models.


Subject(s)
Air Pollutants, Occupational/analysis , Computer Simulation/statistics & numerical data , Hydrodynamics , Torso/anatomy & histology , Aerosols , Air Movements , Dust , Environmental Monitoring/methods , Humans , Inhalation , Inhalation Exposure , Manikins , Models, Biological , Models, Theoretical , Wind