1.
Preprint in English | medRxiv | ID: ppmedrxiv-20221317

ABSTRACT

BackgroundDuring the COVID-19 pandemic, the need for noninvasive respiratory support devices has dramatically increased, sometimes exceeding hospital capacity. The full-face Decathlon snorkeling mask, EasyBreath(R) (EB(R) mask), has been adapted to deliver continuous positive airway pressure (CPAP) as an emergency respiratory interface. We aimed to assess the performance of this modified EB(R) mask. MethodsCPAP set at 5, 10, and 15 cmH2O was delivered to 10 healthy volunteers with a high-flow system generator set at 40, 80, and 120 L min-1 and with a turbine-driven ventilator during both spontaneous and loaded (resistor) breathing. Inspiratory CO2 partial pressure (PiCO2), pressure inside the mask, breathing pattern and electrical activity of the diaphragm (EAdi) were measured at all combinations of CPAP/flows delivered, with and without the resistor. ResultsUsing the high-flow generator set at 40 L min-1, the PiCO2 significantly increased and the system was unable to maintain the target CPAP of 10 and 15 cmH2O and a stable pressure within the respiratory cycle; conversely, the turbine-driven ventilator did. EAdi significantly increased with flow rates of 40 and 80 L min-1 but not at 120 L min-1 and with the turbine-driven ventilator. ConclusionsEB(R) mask can be safely used to deliver CPAP only under strict constraints, using either a high-flow generator at a flow rate greater than 80 L min-1, or a high-performance turbine-driven ventilator.

2.
Preprint in English | medRxiv | ID: ppmedrxiv-20111013

ABSTRACT

IntroductionNoninvasive respiratory support (NRS) such as noninvasive ventilation (NIV) and high flow nasal therapy (HFNT) have been used in the treatment of acute hypoxemic respiratory failure (AHRF) related to the coronavirus disease (COVID-19) and other viral infections. However, there is a lack of consensus in favor of or against NRS use due to the risks of worsening hypoxemia, intubation delay, and aerosols environmental contamination associated with the use of these tools. We aimed to summarize the evidence on the use of NRS in adult patients with COVID-19 and other viral pneumonia (i.e. H1N1, SARS, MERS) and AHRF. We also searched for studies evaluating the risk of aerosolization/contamination with these tools. Evidence AcquisitionWe searched MEDLINE, PubMed EMBASE and two major preprint servers (biorXiv and medRxiv) from inception to April 14, 2020, for studies on the use of respiratory support in AHRF and viral pneumonia. Evidence SynthesisThe search identified 4086 records and we found only one randomized controlled trial out of 58 studies included, with great variabilities in support utilization and failure rates. Fifteen studies explored the issue of aerosolization/contamination showing a high risk of airborne transmission via droplets generation during the use of these modalities ConclusionsUse of NRS and treatment failure in the context of COVID-19 and viral infection associated-AHRF, varied widely. Dispersion of exhaled air is different depending on the type of respiratory therapies and interfaces. Data from randomized controlled trials are lacking.

SELECTION OF CITATIONS
SEARCH DETAIL
...