Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Med ; 13(10)2024 May 15.
Article in English | MEDLINE | ID: mdl-38792463

ABSTRACT

Primary percutaneous coronary intervention (pPCI) has revolutionized the prognosis of ST-segment elevation myocardial infarction (STEMI) and is the gold standard treatment. As a result of its success, the number of pPCI centres has expanded worldwide. Despite decades of advancements, clinical outcomes in STEMI patients have plateaued. Out-of-hospital cardiac arrest and cardiogenic shock remain a major cause of high in-hospital mortality, whilst the growing burden of heart failure in long-term STEMI survivors presents a growing problem. Many elements aiming to optimize STEMI treatment are still subject to debate or lack sufficient evidence. This review provides an overview of the most contentious current issues in pPCI in STEMI patients, with an emphasis on unresolved questions and persistent challenges.

2.
Am J Cardiol ; 217: 144-152, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38431052

ABSTRACT

Coronary angiography (CA) is poorly correlated with non-invasive myocardial stress imaging (NSI) and myocardial ischemia is often observed in patients with unobstructed coronary arteries. Moreover, the diagnostic performance of combined epicardial and microcirculatory angiography-derived physiological assessment and its correlation with NSI remains unknown. A total of 917 coronary vessels in 319 patients who underwent both CA and NSI were included in this multicenter observational retrospective analysis. Quantitative flow ratio (QFR) and angiography-derived index of microcirculatory resistance (IMRangio) analyses were performed to estimate coronary epicardial and microcirculatory function respectively. NSI demonstrated evidence of myocardial ischemia in 76% of the cases. IMRangio (36 [22 to 50] vs 29 [21 to 41], p <0.001) was significantly higher and QFR (0.92 [0.78 to 0.99] vs 0.97 [0.91 to 0.99], p <0.001) was significantly lower in vessels subtending ischemic territories. Overall, the diagnostic accuracy of QFR was moderate (area under the curve of receiver operating characteristic [AUCROC] 0.632 [95% confidence interval [CI] 0.589 to 0.674], p <0.0001) but it was higher in patients with normal microcirculatory function (AUCROC = 0.726 [95% CI 0.669 to 0.784], p <0.0001, p Value for AUCROC comparison = 0.009). Combined QFR/IMRangio assessment provided incremental diagnostic performance compared with the evaluation of epicardial or microcirculatory districts in isolation (p Value for AUC comparison <0.0001) and it was able to identify the predominant mechanism of myocardial ischemia in 77% of the patients with positive NSI. Our study suggests the value of a combined angiography-derived assessment of epicardial and microvascular function for the definition of the predominant mechanism of myocardial ischemia in patients with suspected coronary artery disease.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Myocardial Ischemia , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnosis , Retrospective Studies , Microcirculation , Fractional Flow Reserve, Myocardial/physiology , Coronary Angiography/methods , Myocardial Ischemia/diagnostic imaging , Coronary Vessels/diagnostic imaging , Predictive Value of Tests
3.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38479968

ABSTRACT

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Registries , Stroke/etiology
4.
Circ Cardiovasc Interv ; 17(3): e013556, 2024 03.
Article in English | MEDLINE | ID: mdl-38375667

ABSTRACT

BACKGROUND: Patients with ST-segment-elevation myocardial infarction but no coronary microvascular injury are at low risk of early cardiovascular complications (ECC). We aim to assess whether nonhyperemic angiography-derived index of microcirculatory resistance (NH-IMRangio) could be a user-friendly tool to identify patients at low risk of ECC, potentially candidates for expedited care pathway and early hospital discharge. METHODS: Retrospective analysis of 2 independent, international, prospective, observational cohorts included 568 patients with ST-segment-elevation myocardial infarction. NH-IMRangio was calculated based on standard coronary angiographic views with 3-dimensional-modeling and computational analysis of the coronary flow. RESULTS: Overall, ECC (a composite of cardiovascular death, cardiogenic shock, acute heart failure, life-threatening arrhythmias, resuscitated cardiac arrest, left ventricular thrombus, post-ST-segment-elevation myocardial infarction mechanical complications, and rehospitalization for acute heart failure or acute myocardial infarction at 30 days follow-up), occurred in 54 (9.3%) patients. NH-IMRangio was significantly correlated with pressure/thermodilution-based index of microcirculatory resistance (r=0.607; P<0.0001) and demonstrated good accuracy in predicting ECC (area under the curve, 0.766 [95% CI, 0.706-0.827]; P<0.0001). Importantly, ECC occurred more frequently in patients with NH-IMRangio ≥40 units (18.1% versus 1.4%; P<0.0001). At multivariable analysis, NH-IMRangio provided incremental prognostic value to conventional clinical, angiographic, and echocardiographic features (adjusted-odds ratio, 14.861 [95% CI, 5.177-42.661]; P<0.0001). NH-IMRangio<40 units showed an excellent negative predictive value (98.6%) in ruling out ECC. Discharging patients with NH-IMRangio<40 units at 48 hours after admission would reduce the total in-hospital stay by 943 days (median 2 [1-4] days per patient). CONCLUSIONS: NH-IMRangio is a valuable risk-stratification tool in patients with ST-segment-elevation myocardial infarction. NH-IMRangio guided strategies to early discharge may contribute to safely shorten hospital stay, optimizing resources utilization.


Subject(s)
Heart Failure , Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Coronary Angiography , Coronary Vessels/diagnostic imaging , Heart Failure/etiology , Microcirculation , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/therapy , Myocardial Infarction/etiology , Patient Discharge , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Retrospective Studies , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/therapy , ST Elevation Myocardial Infarction/etiology , Treatment Outcome , Observational Studies as Topic
5.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38401656

ABSTRACT

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Female , Aortic Valve Stenosis/surgery , Sex Factors , Aged, 80 and over , Aged , Treatment Outcome , Postoperative Complications/epidemiology , Aortic Valve/surgery
6.
Heart ; 110(8): 603-612, 2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38040448

ABSTRACT

OBJECTIVES: This study aimed to evaluate the prognostic value of coronary microvascular dysfunction (CMD) at long term after transcatheter aortic valve implantation (TAVI) and to explore its relationship with extravalvular cardiac damage (EVCD). Moreover, we sought to test the correlation between angiography-derived index of microcirculatory resistance (IMRangio) and invasive IMR in patients with aortic stenosis (AS). METHODS: This was a retrospective analysis of the Verona Valvular Heart Disease Registry (Italy) including 250 patients (83 (80-86) years, 53% female) with severe AS who underwent TAVI between 2019 and 2021. IMRangio was calculated offline using a computational flow model applied to coronary angiography obtained during the TAVI workup. CMD was defined as IMRangio ≥30 units.The primary endpoint was the composite of cardiovascular death and rehospitalisation for heart failure (HF). Advanced EVCD was defined as pulmonary circulation impairment, severe tricuspid regurgitation or right ventricular dysfunction.The correlation between IMR and IMRangio was prospectively assessed in 31 patients undergoing TAVI. RESULTS: The primary endpoint occurred in 28 (11.2%) patients at a median follow-up of 22 (IQR 12-30) months. Patients with CMD met the primary endpoint more frequently than those without CMD (22.9% vs 2.8%, p<0.0001). Patients with CMD were more frequently characterised by advanced EVCD (33 (31.4%) vs 27 (18.6%), p=0.024). CMD was an independent predictor of adverse outcomes (adjusted HR 6.672 (2.251 to 19.778), p=0.001) and provided incremental prognostic value compared with conventional clinical and imaging variables. IMRangio demonstrated fair correlation with IMR. CONCLUSIONS: CMD is an independent predictor of cardiovascular mortality and HF after TAVI.


Subject(s)
Aortic Valve Stenosis , Myocardial Ischemia , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Microcirculation , Treatment Outcome , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
7.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37982161

ABSTRACT

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Registries , Stroke/etiology , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...