Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38647991

ABSTRACT

Patients with burn injury and inhalation injury are highly susceptible to infectious complications, including opportunistic pathogens, due to the loss of skin cover and mucosal damage of respiratory tract as well as the disruption of homeostasis. This case report, a 34-year-old man suffered critical burns, provides the first literature description of triple-impact immunoparalysis (critical burns, inhalation injury, and SARS-CoV-2 infection), leading to a lethal multifocal infection caused by several fungi including very rare environmental representatives Metschnikowia pulcherrima and Wickerhamomyces anomalus. The co-infection by these common environmental yeasts in a human is unique and has not yet been described in the literature. Importantly, our patient developed refractory septic shock and died despite targeted antifungal therapy including the most potent current antifungal agent-isavuconazole. It can be assumed that besides immunoparalysis, effectiveness of therapy by isavuconazole was impaired by the large distribution volume in this case. As this is a common situation in intensive care patients, routine monitoring of plasmatic concentration of isavuconazole can be helpful in personalization of the treatment and dose optimization. Whatmore, many fungal species often remain underdiagnosed during infectious complications, which could be prevented by implementation of new methods, such as next-generation sequencing, into clinical practice.

2.
Sci Rep ; 11(1): 11469, 2021 06 01.
Article in English | MEDLINE | ID: mdl-34075135

ABSTRACT

The study introduces and validates a novel high-frequency (100-400 Hz bandwidth, 2 kHz sampling frequency) electrocardiographic imaging (HFECGI) technique that measures intramural ventricular electrical activation. Ex-vivo experiments and clinical measurements were employed. Ex-vivo, two pig hearts were suspended in a human-torso shaped tank using surface tank electrodes, epicardial electrode sock, and plunge electrodes. We compared conventional epicardial electrocardiographic imaging (ECGI) with intramural activation by HFECGI and verified with sock and plunge electrodes. Clinical importance of HFECGI measurements was performed on 14 patients with variable conduction abnormalities. From 3 × 4 needle and 108 sock electrodes, 256 torso or 184 body surface electrodes records, transmural activation times, sock epicardial activation times, ECGI-derived activation times, and high-frequency activation times were computed. The ex-vivo transmural measurements showed that HFECGI measures intramural electrical activation, and ECGI-HFECGI activation times differences indicate endo-to-epi or epi-to-endo conduction direction. HFECGI-derived volumetric dyssynchrony was significantly lower than epicardial ECGI dyssynchrony. HFECGI dyssynchrony was able to distinguish between intraventricular conduction disturbance and bundle branch block patients.


Subject(s)
Diagnostic Imaging , Electrocardiography , Heart Conduction System , Heart Ventricles , Animals , Heart Conduction System/diagnostic imaging , Heart Conduction System/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Humans , Swine
3.
J Cardiovasc Electrophysiol ; 31(1): 300-307, 2020 01.
Article in English | MEDLINE | ID: mdl-31788894

ABSTRACT

INTRODUCTION: The present study introduces a new ultra-high-frequency 14-lead electrocardiogram technique (UHF-ECG) for mapping ventricular depolarization patterns and calculation of novel dyssynchrony parameters that may improve the selection of patients and application of cardiac resynchronization therapy (CRT). METHODS: Components of the ECG in sixteen frequency bands within the 150 to 1000 Hz range were used to create ventricular depolarization maps. The maximum time difference between the UHF QRS complex centers of mass of leads V1 to V8 was defined as ventricular electrical dyssynchrony (e-DYS), and the duration at 50% of peak voltage amplitude in each lead was defined as the duration of local depolarization (Vd). Proof of principle measurements was performed in seven patients with left (left bundle branch block) and four patients with right bundle branch block (right bundle branch block) before and during CRT using biventricular and His-bundle pacing. RESULTS: The acquired activation maps reflect the activation sequence under the tested conditions. e-DYS decreased considerably more than QRS duration, during both biventricular pacing (-50% vs -8%) and His-bundle pacing (-77% vs -13%). While biventricular pacing slightly increased Vd, His-bundle pacing reduced Vd significantly (+11% vs -36%), indicating the contribution of the fast conduction system. Optimization of biventricular pacing by adjusting VV-interval showed a decrease of e-DYS from 102 to 36 ms with only a small Vd increase and QRS duration decrease. CONCLUSIONS: The UHF-ECG technique provides novel information about electrical activation of the ventricles from a standard ECG electrode setup, potentially improving the selection of patients for CRT and application of CRT.


Subject(s)
Bundle of His/physiopathology , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy , Electrocardiography , Heart Failure/therapy , Heart Rate , Action Potentials , Aged , Aged, 80 and over , Bundle-Branch Block/diagnosis , Bundle-Branch Block/physiopathology , Female , Heart Failure/diagnosis , Heart Failure/physiopathology , Humans , Male , Predictive Value of Tests , Proof of Concept Study , Time Factors , Treatment Outcome , Ventricular Function, Left , Ventricular Function, Right
SELECTION OF CITATIONS
SEARCH DETAIL
...