Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sleep ; 30(12): 1771-8, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18246986

ABSTRACT

STUDY OBJECTIVES: In a previous study, we validated a polysomnographic assessment for REM sleep behavior disorder (RBD). The method proved to be reliable but required slow, labor-intensive visual scoring of surface electromyogram (EMG) activity. We therefore developed a computerized metric to assess EMG variance and compared the results to those previously published for visual scoring, bed partner-rated RBD symptom scores, and clinical assessments by sleep medicine specialists. DESIGN: Retrospective validation of new computer algorithm. SETTING: Sleep research laboratory PARTICIPANTS: Twenty-three subjects: 17 with neurodegenerative disorders (9 with probable or possible RBD), and 6 controls. INTERVENTIONS: N/A METHODS: We visually scored 2 consecutive nocturnal polysomnograms for each subject. A computer algorithm calculated the variance of the chin EMG during all 3-second mini-epochs, and compared variances during REM sleep to a threshold defined by variances during quiet NREM sleep. The percentage of all REM mini-epochs with variance above this threshold created a metric, which we refer to as the supra-threshold REM EMG activity metric (STREAM) for each subject. RESULTS: The STREAM correlated highly with the visually-derived score for RBD severity (Spearman rho = 0.87, P < 0.0001). A clinical impression of probable or possible RBD was associated to a similar extent with both STREAM (Wilcoxon rank sum test, P = 0.009) and the visually-derived score (P = 0.018). An optimal STREAM cutoff identified probable or possible RBD with 100% sensitivity and 71% specificity. The RBD symptom score correlated with both STREAM (rho = 0.42, P = 0.046) and the visual score (rho = 0.42, P = 0.048). CONCLUSIONS: These results suggest that a new, automated assessment for RBD may provide as much utility as a more time-consuming manual approach.


Subject(s)
Electromyography/instrumentation , Polysomnography/instrumentation , REM Sleep Behavior Disorder/diagnosis , Signal Processing, Computer-Assisted/instrumentation , Aged , Algorithms , Data Display , Female , Humans , Male , Mathematical Computing , Middle Aged , Neurodegenerative Diseases/complications , Neurodegenerative Diseases/diagnosis , REM Sleep Behavior Disorder/etiology , ROC Curve
2.
Sleep ; 28(8): 993-7, 2005 Aug 01.
Article in English | MEDLINE | ID: mdl-16218083

ABSTRACT

STUDY OBJECTIVES: Rapid eye movement (REM) sleep behavior disorder (RBD) was described more than 2 decades ago, but only 1 report on 5 patients and 5 normal subjects has tested the effectiveness of a method by which relevant polysomnographic findings can be quantified. We sought to validate this method in a larger sample of patients and control subjects. DESIGN: Cross-sectional. SETTING: Academic hospital. INTERVENTIONS: A clinician interviewed 17 patients at risk for RBD secondary to neurodegenerative disorders and 6 controls to assess whether RBD was present by history. Bed partners completed a questionnaire that quantified RBD symptom severity. From 2 consecutive nocturnal studies in each patient, 2 different polysomnographic RBD scores were generated: the percentage of 30-second REM epochs with at least 15 seconds of tonically maintained electromyographic activity, and the percentage of 3-second REM mini-epochs that contained phasic electromyographic bursts. MEASUREMENTS AND RESULTS: The tonic and phasic measures, combined together, were higher in patients with clinical determinations of probable or possible RBD (n=9) than in patients judged unlikely to have RBD (n=4, P = .023). The overall polysomnographic measure correlated with the symptom scores (rho = 0.42, P = .048). Specific polysomnographic RBD measures on night 1 correlated highly with those on night 2 (rho > 0.70, P < .0001). CONCLUSIONS: This quantitative method to assess the severity of RBD polysomnographic features appears to be both valid and reliable in patients at risk for RBD because of neurodegenerative disorders.


Subject(s)
Polysomnography/methods , REM Sleep Behavior Disorder/diagnosis , Aged , Cross-Sectional Studies , Electromyography , Female , Health Status , Humans , Male , Middle Aged , Reproducibility of Results , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...