Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Neuroeng Rehabil ; 20(1): 17, 2023 01 27.
Article in English | MEDLINE | ID: mdl-36707885

ABSTRACT

BACKGROUND: Assistive hand exoskeletons are promising tools to restore hand function after cervical spinal cord injury (SCI) but assessing their specific impact on bimanual hand and arm function is limited due to lack of reliable and valid clinical tests. Here, we introduce the Berlin Bimanual Test for Tetraplegia (BeBiTT) and demonstrate its psychometric properties and sensitivity to assistive hand exoskeleton-related improvements in bimanual task performance. METHODS: Fourteen study participants with subacute cervical SCI performed the BeBiTT unassisted (baseline). Thereafter, participants repeated the BeBiTT while wearing a brain/neural hand exoskeleton (B/NHE) (intervention). Online control of the B/NHE was established via a hybrid sensorimotor rhythm-based brain-computer interface (BCI) translating electroencephalographic (EEG) and electrooculographic (EOG) signals into open/close commands. For reliability assessment, BeBiTT scores were obtained by four independent observers. Besides internal consistency analysis, construct validity was assessed by correlating baseline BeBiTT scores with the Spinal Cord Independence Measure III (SCIM III) and Quadriplegia Index of Function (QIF). Sensitivity to differences in bimanual task performance was assessed with a bootstrapped paired t-test. RESULTS: The BeBiTT showed excellent interrater reliability (intraclass correlation coefficients > 0.9) and internal consistency (α = 0.91). Validity of the BeBiTT was evidenced by strong correlations between BeBiTT scores and SCIM III as well as QIF. Wearing a B/NHE (intervention) improved the BeBiTT score significantly (p < 0.05) with high effect size (d = 1.063), documenting high sensitivity to intervention-related differences in bimanual task performance. CONCLUSION: The BeBiTT is a reliable and valid test for evaluating bimanual task performance in persons with tetraplegia, suitable to assess the impact of assistive hand exoskeletons on bimanual function.


Subject(s)
Exoskeleton Device , Spinal Cord Injuries , Humans , Psychometrics , Reproducibility of Results , Berlin , Hand , Quadriplegia/diagnosis , Quadriplegia/rehabilitation , Spinal Cord Injuries/rehabilitation
2.
Neurorehabil Neural Repair ; 36(12): 747-756, 2022 12.
Article in English | MEDLINE | ID: mdl-36426541

ABSTRACT

The development of brain-computer interface-controlled exoskeletons promises new treatment strategies for neurorehabilitation after stroke or spinal cord injury. By converting brain/neural activity into control signals of wearable actuators, brain/neural exoskeletons (B/NEs) enable the execution of movements despite impaired motor function. Beyond the use as assistive devices, it was shown that-upon repeated use over several weeks-B/NEs can trigger motor recovery, even in chronic paralysis. Recent development of lightweight robotic actuators, comfortable and portable real-world brain recordings, as well as reliable brain/neural control strategies have paved the way for B/NEs to enter clinical care. Although B/NEs are now technically ready for broader clinical use, their promotion will critically depend on early adopters, for example, research-oriented physiotherapists or clinicians who are open for innovation. Data collected by early adopters will further elucidate the underlying mechanisms of B/NE-triggered motor recovery and play a key role in increasing efficacy of personalized treatment strategies. Moreover, early adopters will provide indispensable feedback to the manufacturers necessary to further improve robustness, applicability, and adoption of B/NEs into existing therapy plans.


Subject(s)
Brain-Computer Interfaces , Exoskeleton Device , Neurological Rehabilitation , Robotics , Humans , Brain
3.
Front Neurol ; 12: 772199, 2021.
Article in English | MEDLINE | ID: mdl-34867760

ABSTRACT

Severe upper limb paresis can represent an immense burden for stroke survivors. Given the rising prevalence of stroke, restoration of severe upper limb motor impairment remains a major challenge for rehabilitation medicine because effective treatment strategies are lacking. Commonly applied interventions in Germany, such as mirror therapy and impairment-oriented training, are limited in efficacy, demanding for new strategies to be found. By translating brain signals into control commands of external devices, brain-computer interfaces (BCIs) and brain-machine interfaces (BMIs) represent promising, neurotechnology-based alternatives for stroke patients with highly restricted arm and hand function. In this mini-review, we outline perspectives on how BCI-based therapy can be integrated into the different stages of neurorehabilitation in Germany to meet a long-term treatment approach: We found that it is most appropriate to start therapy with BCI-based neurofeedback immediately after early rehabilitation. BCI-driven functional electrical stimulation (FES) and BMI robotic therapy are well suited for subsequent post hospital curative treatment in the subacute stage. BCI-based hand exoskeleton training can be continued within outpatient occupational therapy to further improve hand function and address motivational issues in chronic stroke patients. Once the rehabilitation potential is exhausted, BCI technology can be used to drive assistive devices to compensate for impaired function. However, there are several challenges yet to overcome before such long-term treatment strategies can be implemented within broad clinical application: 1. developing reliable BCI systems with better usability; 2. conducting more research to improve BCI training paradigms and 3. establishing reliable methods to identify suitable patients.

4.
Front Hum Neurosci ; 14: 580105, 2020.
Article in English | MEDLINE | ID: mdl-33362490

ABSTRACT

Cervical spinal cord injuries (SCIs) often lead to loss of motor function in both hands and legs, limiting autonomy and quality of life. While it was shown that unilateral hand function can be restored after SCI using a hybrid electroencephalography/electrooculography (EEG/EOG) brain/neural hand exoskeleton (B/NHE), it remained unclear whether such hybrid paradigm also could be used for operating two hand exoskeletons, e.g., in the context of bimanual tasks such as eating with fork and knife. To test whether EEG/EOG signals allow for fluent and reliable as well as safe and user-friendly bilateral B/NHE control, eight healthy participants (six females, mean age 24.1 ± 3.2 years) as well as four chronic tetraplegics (four males, mean age 51.8 ± 15.2 years) performed a complex sequence of EEG-controlled bilateral grasping and EOG-controlled releasing motions of two exoskeletons visually presented on a screen. A novel EOG command performed by prolonged horizontal eye movements (>1 s) to the left or right was introduced as a reliable switch to activate either the left or right exoskeleton. Fluent EEG control was defined as average "time to initialize" (TTI) grasping motions below 3 s. Reliable EEG control was assumed when classification accuracy exceeded 80%. Safety was defined as "time to stop" (TTS) all unintended grasping motions within 2 s. After the experiment, tetraplegics were asked to rate the user-friendliness of bilateral B/NHE control using Likert scales. Average TTI and accuracy of EEG-controlled operations ranged at 2.14 ± 0.66 s and 85.89 ± 15.81% across healthy participants and at 1.90 ± 0.97 s and 81.25 ± 16.99% across tetraplegics. Except for one tetraplegic, all participants met the safety requirements. With 88 ± 11% of the maximum achievable score, tetraplegics rated the control paradigm as user-friendly and reliable. These results suggest that hybrid EEG/EOG B/NHE control of two assistive devices is feasible and safe, paving the way to test this paradigm in larger clinical trials performing bimanual tasks in everyday life environments.

SELECTION OF CITATIONS
SEARCH DETAIL
...