Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Acquir Immune Defic Syndr ; 89(2): 178-182, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34693933

ABSTRACT

BACKGROUND: HIV protease inhibitors anti-Plasmodium falciparum activity in adults remains uncertain. METHODS: Adults with HIV CD4+ counts >200 cells/mm3 starting antiretroviral therapy (ART) with P. falciparum subclinical parasitemia (Pf SCP) were randomized 1:1 to (step 1) protease inhibitor lopinavir/ritonavir (LPV/r)-based (arm A) or nonnucleoside reverse transcriptase inhibitor (nNRTI)-based ART (arm B) for 15 days. In step 2, participants received nNRTI-based ART and trimethoprim/sulfamethoxazole prophylaxis for 15 days. P. falciparum SCP clearance was measured by polymerase chain reaction. The Fisher exact test [95% exact confidence interval (CI)] was used to compare proportions of P. falciparum SCP clearance (<10 parasites/µL on 3 occasions within 24 hours) between LPV/r and nNRTI arms at day 15. The Kaplan-Meier method and log-rank test were used to compare time-to-clearance. RESULTS: Fifty-two adults from Kenya, Malawi, and Uganda with a median age = 31 (Q1, Q3: 24-39) years, 33% women, with baseline median CD4+ counts of 324 (259-404) cells/mm3, median HIV-1 RNA viremia of 5.18 log10 copies/mL (4.60-5.71), and median estimated P. falciparum density of 454 parasites/µL (83-2219) enrolled in the study. Forty-nine (94%) participants completed the study. At day 15, there was no statistically significant difference in the proportions of P. falciparum SCP clearance between the LPV/r (23.1% clearance; 6 of the 26) and nNRTI (26.9% clearance; 7 of the 26) arms [between-arm difference 3.9% (95% CI, -21.1% to 28.4%; P = 1.00)]. No significant difference in time-to-clearance was observed between the arms (P = 0.80). CONCLUSIONS: In a small randomized study of adults starting ART with P. falciparum SCP, no statistically significant differences were seen between LPV/r- and nNRTI-based ART in P. falciparum SCP clearance after 15 days of treatment.


Subject(s)
Anti-HIV Agents , HIV Infections , HIV Protease Inhibitors , Adult , Female , HIV Infections/complications , HIV Infections/drug therapy , HIV Protease Inhibitors/therapeutic use , Humans , Lopinavir , Male , Parasitemia/drug therapy , Plasmodium falciparum , Reverse Transcriptase Inhibitors/therapeutic use , Ritonavir
2.
Pharmacogenet Genomics ; 32(1): 24-30, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34369424

ABSTRACT

OBJECTIVE: In AIDS Clinical Trials Group study A5338, concomitant rifampicin, isoniazid, and efavirenz was associated with more rapid plasma medroxyprogesterone acetate (MPA) clearance compared to historical controls without tuberculosis or HIV therapy. We characterized the pharmacogenetics of this interaction. METHODS: In A5338, women receiving efavirenz-based HIV therapy and rifampicin plus isoniazid for tuberculosis underwent pharmacokinetic evaluations over 12 weeks following a 150-mg intramuscular injection of depot MPA. Data were interpreted with nonlinear mixed-effects modelling. Associations between individual pharmacokinetic parameters and polymorphisms relevant to rifampicin, isoniazid, efavirenz, and MPA were assessed. RESULTS: Of 62 A5338 participants in four African countries, 44 were evaluable for pharmacokinetic associations, with 17 CYP2B6 normal, 21 intermediate, and 6 poor metabolizers, and 5 NAT2 rapid, 20 intermediate, and 19 slow acetylators. There were no associations between either CYP2B6 or NAT2 genotype and MPA Cmin at week 12, apparent clearance, Cmax, area under the concentration-time curve (AUC) or half-life, or unexplained interindividual variability in clearance, and uptake rate constant or mean transit time of the slow-release fraction (P > 0.05 for each). In exploratory analyses, none of 28 polymorphisms in 14 genes were consistently associated with MPA pharmacokinetic parameters, and none withstood correction for multiple testing. CONCLUSIONS: Study A5338 suggested that more frequent depot MPA dosing may be appropriate for women receiving rifampicin, isoniazid, and efavirenz. The present results suggest that knowledge of CYP2B6 metabolizer or NAT2 acetylator status does not inform individualized DMPA dosing in this setting.


Subject(s)
HIV Infections , Tuberculosis , Anti-HIV Agents/adverse effects , Antitubercular Agents/adverse effects , Benzoxazines/adverse effects , Drug Interactions , Female , HIV Infections/drug therapy , HIV Infections/genetics , Humans , Isoniazid/adverse effects , Medroxyprogesterone Acetate/adverse effects , Pharmacogenetics , Rifampin/adverse effects , Tuberculosis/drug therapy , Tuberculosis/genetics
4.
Open AIDS J ; 11: 76-90, 2017.
Article in English | MEDLINE | ID: mdl-29290885

ABSTRACT

BACKGROUND: The BD FACSPresto™ system uses capillary and venous blood to measure CD4 absolute counts (CD4), %CD4 in lymphocytes, and hemoglobin (Hb) in approximately 25 minutes. CD4 cell count is used with portable CD4 counters in resource-limited settings to manage HIV/AIDS patients. A method comparison was performed using capillary and venous samples from seven clinical laboratories in five countries. The BD FACSPresto system was assessed for variability between laboratory, instrument/operators, cartridge lots and within-run at four sites. METHODS: Samples were collected under approved voluntary consent. EDTA-anticoagulated venous samples were tested for CD4 and %CD4 T cells using the gold-standard BD FACSCalibur™ system, and for Hb, using the Sysmex® KX-21N™ analyzer. Venous and capillary samples were tested on the BD FACSPresto system. Matched data was analyzed for bias (Deming linear regression and Bland-Altman methods), and for concordance around the clinical decision point. The coefficient of variation was estimated per site, instrument/operator, cartridge-lot and between-runs. RESULTS: For method comparison, 93% of the 720 samples were from HIV-positive and 7% from HIV-negative or normal subjects. CD4 and %CD4 T cells venous and capillary results gave slopes within 0.96-1.05 and R2 ≥0.96; Hb slopes were ≥1.00 and R2 ≥0.89. Variability across sites/operators gave %CV <5.8% for CD4 counts, <1.9% for %CD4 and <3.2% for Hb. The total %CV was <7.7% across instrument/cartridge lot. CONCLUSION: The BD FACSPresto system provides accurate, reliable, precise CD4/%CD4/Hb results compared to gold-standard methods, irrespective of venous or capillary blood sampling. The data showed good agreement between the BD FACSPresto, BD FACSCalibur and Sysmex systems.

5.
PLoS One ; 11(8): e0157939, 2016.
Article in English | MEDLINE | ID: mdl-27483008

ABSTRACT

BACKGROUND: The BD FACSPresto™ Near-Patient CD4 Counter was developed to expand HIV/AIDS management in resource-limited settings. It measures absolute CD4 counts (AbsCD4), percent CD4 (%CD4), and hemoglobin (Hb) from a single drop of capillary or venous blood in approximately 23 minutes, with throughput of 10 samples per hour. We assessed the performance of the BD FACSPresto system, evaluating accuracy, stability, linearity, precision, and reference intervals using capillary and venous blood at KEMRI/CDC HIV-research laboratory, Kisumu, Kenya, and precision and linearity at BD Biosciences, California, USA. METHODS: For accuracy, venous samples were tested using the BD FACSCalibur™ instrument with BD Tritest™ CD3/CD4/CD45 reagent, BD Trucount™ tubes, and BD Multiset™ software for AbsCD4 and %CD4, and the Sysmex™ KX-21N for Hb. Stability studies evaluated duration of staining (18-120-minute incubation), and effects of venous blood storage <6-24 hours post-draw. A normal cohort was tested for reference intervals. Precision covered multiple days, operators, and instruments. Linearity required mixing two pools of samples, to obtain evenly spaced concentrations for AbsCD4, total lymphocytes, and Hb. RESULTS: AbsCD4 and %CD4 venous/capillary (N = 189/ N = 162) accuracy results gave Deming regression slopes within 0.97-1.03 and R2 ≥0.96. For Hb, Deming regression results were R2 ≥0.94 and slope ≥0.94 for both venous and capillary samples. Stability varied within 10% 2 hours after staining and for venous blood stored less than 24 hours. Reference intervals results showed that gender-but not age-differences were statistically significant (p<0.05). Precision results had <3.5% coefficient of variation for AbsCD4, %CD4, and Hb, except for low AbsCD4 samples (<6.8%). Linearity was 42-4,897 cells/µL for AbsCD4, 182-11,704 cells/µL for total lymphocytes, and 2-24 g/dL for Hb. CONCLUSIONS: The BD FACSPresto system provides accurate, precise clinical results for capillary or venous blood samples and is suitable for near-patient CD4 testing. TRIAL REGISTRATION: ClinicalTrials.gov NCT02396355.


Subject(s)
CD4 Lymphocyte Count/methods , HIV Infections/blood , Adolescent , Adult , Aged , CD4-Positive T-Lymphocytes/immunology , Child , Child, Preschool , Female , Flow Cytometry/methods , HIV Infections/immunology , Humans , Kenya/epidemiology , Male , Middle Aged , Sensitivity and Specificity , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...