Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J Rheumatol ; 36(8): 1825-8, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19671820

ABSTRACT

Previously reported data on 5 computer-based programs for measurement of joint space width focusing on discriminating ability and reproducibility are updated, showing new data. Four of 5 different programs for measuring joint space width were more discriminating than observer scoring for change in narrowing in the 12 months interval. Three of 4 programs were more discriminating than observer scoring for the 0-18 month interval. The program that failed to discriminate in the 0-12 month interval was not the same program that failed in the 0-18 month interval. The committee agreed at an interim meeting in November 2007 that an important goal for computer-based measurement programs is a 90% success rate in making measurements of joint pairs in followup studies. This means that the same joint must be measured in images of both timepoints in order to assess change over time in serial radiographs. None of the programs met this 90% threshold, but 3 programs achieved 85%-90% success rate. Intraclass correlation coefficients for assessing change in joint space width in individual joints were 0.98 or 0.99 for 4 programs. The smallest detectable change was < 0.2 mm for 4 of the 5 programs, representing 29%-36% of the change within the 99th percentile of measurements.


Subject(s)
Arthritis/diagnostic imaging , Arthrography/methods , Arthrography/standards , Image Processing, Computer-Assisted/methods , Image Processing, Computer-Assisted/standards , Humans , Reproducibility of Results , Software/standards
2.
J Rheumatol ; 35(7): 1288-93, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18597408

ABSTRACT

OBJECTIVE: Comparison of performances of 5 (semi)automated methods in measuring joint space width (JSW) in rheumatoid arthritis. METHODS: Change in JSW was determined by 5 measurement methods on 4 radiographs per patient from 107 patients included in the COBRA trial (comparing sulfasalazine alone or in combination with methotrexate and corticosteroids). For each method the number of patients with sufficient available results was assessed (efficiency). An independent repeated measurement was carried out on a random sample of 30 patients' baseline and 1-year radiographs, to evaluate within-method reliability of change scores. Discriminatory ability (DA) of the measurement methods (between the 2 treatment arms) was compared with the DA of the Sharp-van der Heijde score (SHS) and its 2 components (erosion and JSW scores). RESULTS: The overall success rate varied widely between methods. Applying the chosen threshold of a minimum of 50% available joints with a change score per patient resulted in a success rate > 92% in 4/5 methods. Repeatability of measurements was good for most methods (intraclass correlation coefficient > or = 0.80 in 4/5 methods). Almost all measurement methods in 3 followup periods (12/14) showed a lower mean loss of JSW in patients from the intensive treatment group, although this was rarely statistically significant, confirming the known difference in structural damage. JSW as measured by the (semi)automated systems often showed higher DA than the JSW score of the SHS, but was lower than the total SHS and erosion scores. CONCLUSION: Although efficiency of the methods should be improved further, results already show good reliability and encouraging DA of most methods. Optimal information may be obtained with a combination of scoring of erosions and (semi)automated measurement of JSW.


Subject(s)
Arthritis, Rheumatoid/diagnostic imaging , Foot Joints/diagnostic imaging , Hand Joints/diagnostic imaging , Arthritis, Rheumatoid/pathology , Arthrography , Foot Joints/pathology , Hand Joints/pathology , Humans , Image Interpretation, Computer-Assisted/methods , Randomized Controlled Trials as Topic
3.
J Rheumatol ; 34(4): 874-83, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17407243

ABSTRACT

Computer-based methods of measuring joint space width (JSW) could potentially have advantages over scoring joint space narrowing, with regard to increased standardization, sensitivity, and reproducibility. In an early exercise, 4 different methods showed good agreement on measured change in JSW over time in the small joints of the hands and feet. Despite differences in measurement values between methods, measurement of within-joint change over time showed no systematic differences. The within-method variation was small, with intra-operator variation being smaller than inter-operator variation. Although this initial study was limited in terms of the number of patients and timepoints (total 10), the number of joints was relatively high (340 joints), so the results were considered strong evidence supporting the validity of computer-based JSW measurements to continue the study of the potential value of JSW by comparison of measurements to manual scoring of joint space narrowing using the COBRA trial images.


Subject(s)
Finger Joint/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Toes/diagnostic imaging , Wrist Joint/diagnostic imaging , Finger Joint/pathology , Humans , Observer Variation , Radiography , Reproducibility of Results , Sensitivity and Specificity , Toes/pathology , Wrist Joint/pathology
4.
J Rheumatol ; 32(12): 2456-61, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16331786

ABSTRACT

Measurement of radiographic abnormalities in metric units has been reported by several investigators during the last 15 years. Measurement of joint space in large joints has been employed in a few trials to evaluate therapy in osteoarthritis. Measurement of joint space width in small joints has been reported by several investigators but has not yet found a place in clinical trials in rheumatoid arthritis or osteoarthritis. We review methods for measuring joint space width in finger, toe, and wrist joints; special attention is given to how the joint edges are found, the method used to measure distance between joint margins, size of an area of the sampled joint, and reproducibility of measurements. Methods for measurement of erosion size, which have had less attention, are briefly discussed.


Subject(s)
Arthrography , Finger Joint/diagnostic imaging , Toe Joint/diagnostic imaging , Wrist Joint/diagnostic imaging , Diagnosis, Computer-Assisted , Humans , Reproducibility of Results
5.
J Rheumatol ; 31(6): 1050-61, 2004 Jun.
Article in English | MEDLINE | ID: mdl-15170915

ABSTRACT

OBJECTIVE: To compare changes in the computerized measurement of radiographic hand joint space width (JSW) to changes in modified Sharp scores in a retrospective 2-year study of early rheumatoid arthritis (RA). METHODS: First and last standard clinical hand radiographs of 245 patients with RA were analyzed blind using purpose-written computer software to measure changes in JSW for proximal interphalangeal (PIP) and metacarpophalangeal (MCP) joints in the 3 middle fingers of each hand. Before measurement, the radiographs were scored independently by 2 radiologists using a modification of Sharp scoring. RESULTS: The paired changes in JSW (-0.051 +/- 0.005 mm) and Sharp score (+3.81 +/- 0.50) were both significant over the study duration. In measured joints showing an increase in joint space narrowing (JSN) score, 92% had a corresponding reduction in JSW. In patients with an increase in total score, including JSN and erosion scores in fingers and wrists, 84% had a corresponding reduction in mean (PIP + MCP) JSW. Patients with no change in Sharp score (47%) still experienced a significant reduction in measured JSW (-0.027 +/- 0.006 mm). HLA-DR genetic markers of severe disease progression were associated with significantly greater reductions in JSW but not increases in Sharp score. ( VALUES: mean +/- standard error of mean). CONCLUSION: Measured JSW averaged over 6 PIP and 6 MCP joints was a valid and more sensitive measure of change than total Sharp score in this study of early RA.


Subject(s)
Arthritis, Rheumatoid/diagnostic imaging , Finger Joint/diagnostic imaging , Image Processing, Computer-Assisted/methods , Wrist Joint/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Arthritis, Rheumatoid/genetics , Early Diagnosis , Female , Genetic Predisposition to Disease , HLA-DR1 Antigen/genetics , HLA-DR4 Antigen/genetics , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Sensitivity and Specificity , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...