ABSTRACT

BACKGROUND: Ultrasound is one of the non-invasive techniques that are used in clinical diagnostics of carotid artery disease. OBJECTIVE: This paper presents software methodology that can be used in combination with this imaging technique to provide additional information about the state of patient-specific artery. METHODS: Overall three modules are combined within the proposed methodology. A clinical dataset is used within the deep learning module to extract the contours of the carotid artery. This data is then used within the second module to perform the three-dimensional reconstruction of the geometry of the carotid bifurcation and ultimately this geometry is used within the third module, where the hemodynamic analysis is performed. The obtained distributions of hemodynamic quantities enable a more detailed analysis of the blood flow and state of the arterial wall and could be useful to predict further progress of present abnormalities in the carotid bifurcation. RESULTS: The performance of the deep learning module was demonstrated through the high values of relevant common classification metric parameters. Also, the accuracy of the proposed methodology was shown through the validation of results for the reconstructed parameters against the clinically measured values. CONCLUSION: The presented methodology could be used in combination with standard clinical ultrasound examination to quickly provide additional quantitative and qualitative information about the state of the patient's carotid bifurcation and thus ensure a treatment that is more adapted to the specific patient.


Subject(s)
Carotid Arteries , Deep Learning , Imaging, Three-Dimensional , Software , Ultrasonography , Humans , Carotid Arteries/diagnostic imaging , Imaging, Three-Dimensional/methods , Ultrasonography/methods , Hemodynamics/physiology , Carotid Artery Diseases/diagnostic imaging
2.
Comput Math Methods Med ; 2022: 5311208, 2022.
Article in English | MEDLINE | ID: mdl-36105243

ABSTRACT

Stents made by different manufacturers must meet the requirements of standard in vitro mechanical tests performed under different physiological conditions in order to be validated. In addition to in vitro research, there is a need for in silico numerical simulations that can help during the stent prototyping phase. In silico simulations have the ability to give the same stent responses as well as the potential to reduce costs and time needed to carry out experimental tests. The goal of this paper is to show the achievements of the computational platform created as a result of the EU-funded project InSilc, used for numerical testing of most standard tests for validation of preproduction bioresorbable vascular scaffolds (BVSs). Within the platform, an ad hoc simulation protocol has been developed based on the finite element (FE) analysis program PAK and user interface software CAD Field and Solid. Two different designs of two different stents have been numerically simulated using this integrated tool, and the results have been demonstrated. The following standard tests have been performed: longitudinal tensile strength, local compression, kinking, and flex 1-3. Strut thickness and additional pocket holes (slots) in two different scaffolds have been used as representative parameters for comparing the mechanical characteristics of the stents (AB-BVS vs. AB-BVS-thinner and PLLA-prot vs. PLLA-plot-slot). The AB-BVS-thinner prototype shows better overall stress distribution than the AB-BVS, while the PLLA-prot shows better overall stress distribution in comparison to the PLLA-plot-slot. In all cases, the values of the maximum effective stresses are below 220 MPa-the value obtained by in vitro experiment. Despite the presented results, additional considerations should be included before the proposed software can be used as a validation tool for stent prototyping.


Subject(s)
Drug-Eluting Stents , Absorbable Implants , Humans , Prosthesis Design , Stents , Tissue Scaffolds
3.
Front Med Technol ; 3: 724062, 2021.
Article in English | MEDLINE | ID: mdl-35047953

ABSTRACT

Bioresorbable vascular scaffolds (BVS), made either from polymers or from metals, are promising materials for treating coronary artery disease through the processes of percutaneous transluminal coronary angioplasty. Despite the opinion that bioresorbable polymers are more promising for coronary stents, their long-term advantages over metallic alloys have not yet been demonstrated. The development of new polymer-based BVS or optimization of the existing ones requires engineers to perform many very expensive mechanical tests to identify optimal structural geometry and material characteristics. in silico mechanical testing opens the possibility for a fast and low-cost process of analysis of all the mechanical characteristics and also provides the possibility to compare two or more competing designs. In this study, we used a recently introduced material model of poly-l-lactic acid (PLLA) fully bioresorbable vascular scaffold and recently empowered numerical InSilc platform to perform in silico mechanicals tests of two different stent designs with different material and geometrical characteristics. The result of inflation, radial compression, three-point bending, and two-plate crush tests shows that numerical procedures with true experimental constitutive relationships could provide reliable conclusions and a significant contribution to the optimization and design of bioresorbable polymer-based stents.

SELECTION OF CITATIONS
SEARCH DETAIL
...