Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
PLoS One ; 18(10): e0292440, 2023.
Article in English | MEDLINE | ID: mdl-37796780

ABSTRACT

Healthcare workers (HCWs) are disproportionately infected with SARS-CoV-2 when compared to members of the general public; estimating the seroprevalence of SARS-CoV-2 antibody and SARS-CoV-2 infection rate among HCWs is therefore crucial. This study was carried out in four health facilities in Lagos Nigeria to determine the prevalence of IgG antibodies (seroprevalence) and SARS-CoV-2 active infection rate via a positive rtPCR result, the cross-sectional study was conducted between December 2020 and July 2021. Nasopharyngeal and blood samples were collected from HCWs and screened for SARS-CoV-2 infection using the rtPCR technique and antibody using the Abbott anti-SARS-CoV-2 IgG CMIA assay, respectively. Demographic and occupational exposures data were obtained and analysed using descriptive and inferential statistics, variables significant via inferential statistics were subjected to a multivariate analysis. A total of 413 participants were enrolled, with a mean age in years of 38.4±11.0. The seroprevalence was 30.9% (115/372) while 63/395 (15.9%) were actively infected with the virus. HCWs whose job role had direct contact with patients had a higher percentage of SARS-CoV-2 infection when compared with those not in direct contact, also being a health care worker was significantly associated with getting a positive COVID-19 PCR result. In conclusion the SARS-CoV-2 seroprevalence seen in this study was higher than national serosurvey estimates indicating HCWs are at higher risk of COVID-19 infection when compared to the general public. Vaccination and effective implementation of infection control measures are important to protect HCWs.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Cross-Sectional Studies , Nigeria/epidemiology , Seroepidemiologic Studies , COVID-19/epidemiology , Antibodies, Viral , Immunoglobulin G , Health Personnel
2.
J Clin Virol Plus ; 3(1): 100139, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36683611

ABSTRACT

Objectives: Determining an accurate estimate of SARS-CoV-2 seroprevalence has been challenging in African countries where malaria and other pathogens are endemic. We compared the performance of one single-antigen assay and three multi-antigen SARS-CoV-2 IgG assays in a Nigerian population endemic for malaria. Methods: De-identified plasma specimens from SARS-CoV-2 RT-PCR positive, dried blood spot (DBS) SARS-CoV-2 RT-PCR positive, and pre-pandemic negatives were used to evaluate the performance of the four SARS-CoV-2 assays (Tetracore, SARS2MBA, RightSign, xMAP). Results: Results showed higher sensitivity with the multi-antigen (81% (Tetracore), 96% (SARS2MBA), 85% (xMAP)) versus the single-antigen (RightSign (64%)) SARS-CoV-2 assay. The overall specificities were 98% (Tetracore), 100% (SARS2MBA and RightSign), and 99% (xMAP). When stratified based on <15 days to ≥15 days post-RT-PCR confirmation, the sensitivities increased from 75% to 88.2% for Tetracore; from 93% to 100% for the SARS2MBA; from 58% to 73% for RightSign; and from 83% to 88% for xMAP. With DBS, there was no positive increase after 15-28 days for the three assays (Tetracore, SARS2MBA, and xMAP). Conclusion: Multi-antigen assays performed well in Nigeria, even with samples with known malaria reactivity, and might provide more accurate measures of COVID-19 seroprevalence and vaccine efficacy.

3.
PLoS One ; 17(4): e0266184, 2022.
Article in English | MEDLINE | ID: mdl-35363818

ABSTRACT

OBJECTIVE: There is a need for reliable serological assays to determine accurate estimates of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) seroprevalence. Most single target antigen assays have shown some limitations in Africa. To assess the performance of a multi-antigen assay, we evaluated a commercially available SARS-CoV-2 Multi-Antigen IgG assay for human coronavirus disease 2019 (COVID-19) in Nigeria. METHODS: Validation of the xMAP SARS-CoV-2 Multi-Antigen IgG assay was carried out using well-characterized SARS-CoV-2 reverse transcription polymerase chain reactive positive (97) and pre-COVID-19 pandemic (86) plasma panels. Cross-reactivity was assessed using pre-COVID-19 pandemic plasma specimens (213) from the 2018 Nigeria HIV/AIDS Indicator and Impact Survey (NAIIS). RESULTS: The overall sensitivity of the xMAP SARS-CoV-2 Multi-Antigen IgG assay was 75.3% [95% CI: 65.8%- 82.8%] and specificity was 99.0% [95% CI: 96.8%- 99.7%]. The sensitivity estimate increased to 83.3% [95% CI: 70.4%- 91.3%] for specimens >14 days post-confirmation of diagnosis. However, using the NAIIS pre-pandemic specimens, the false positivity rate was 1.4% (3/213). CONCLUSIONS: Our results showed overall lower sensitivity and a comparable specificity with the manufacturer's validation. There appears to be less cross-reactivity with NAIIS pre-pandemic COVID-19 specimens using the xMAP SARS-CoV-2 Multi-Antigen IgG assay. In-country SARS-CoV-2 serology assay validation can help guide the best choice of assays in Africa.


Subject(s)
COVID-19 , Pandemics , Antibodies, Viral , COVID-19/diagnosis , COVID-19/epidemiology , Humans , Immunoglobulin G , Nigeria/epidemiology , SARS-CoV-2 , Sensitivity and Specificity , Seroepidemiologic Studies
4.
Microbiol Spectr ; 9(2): e0068021, 2021 10 31.
Article in English | MEDLINE | ID: mdl-34612691

ABSTRACT

Validated assays are essential for reliable serosurveys; however, most SARS-CoV-2 immunoassays have been validated using specimens from China, Europe, or U.S. populations. We evaluated the performance of five commercial SARS-CoV-2 immunoassays to inform their use in serosurveys in Nigeria. Four semiquantitative enzyme-linked immunosorbent assays (ELISAs) (Euroimmun anti-SARS-CoV-2 nucleocapsid protein [NCP] immunoglobulin G [IgG], Euroimmun spike SARS-CoV-2 IgG, Mologic Omega COVID-19 IgG, Bio-Rad Platelia SARS-CoV-2 Total Ab) and one chemiluminescent microparticle immunoassay (Abbott Architect SARS-CoV-2 IgG) were evaluated. We estimated the analytical performance characteristics using plasma from 100 SARS-CoV-2 PCR-positive patients from varied time points post-PCR confirmation and 100 prepandemic samples (50 HIV positive and 50 hepatitis B positive). The Bio-Rad assay failed the manufacturer-specified validation steps. The Euroimmun NCP, Euroimmun spike, and Mologic assays had sensitivities of 73.7%, 74.4%, and 76.9%, respectively, on samples taken 15 to 58 days after PCR confirmation and specificities of 97%, 100%, and 83.8%, respectively. The Abbott assay had 71.3% sensitivity and 100% specificity on the same panel. Parallel or serial algorithms combining two tests did not substantially improve the sensitivity or specificity. Our results showed lower sensitivity and, for one immunoassay, lower specificity compared to the manufacturers' results and other reported validations. Seroprevalence estimates using these assays might need to be interpreted with caution in Nigeria and similar settings. These findings highlight the importance of in-country validations of SARS-CoV-2 serological assays prior to use to ensure that accurate results are available for public health decision-making to control the COVID-19 pandemic in Africa. IMPORTANCE This study used positive and negative sample panels from Nigeria to test the performance of several commercially available SARS-CoV-2 serological assays. Using these prepandemic and SARS-CoV-2-positive samples, we found much lower levels of sensitivity in four commercially available assays than most assay manufacturer reports and independent evaluations. The use of these assays with suboptimal sensitivity and specificity in Nigeria or countries with population exposure to similar endemic pathogens could lead to a biased estimate of the seroprevalence, over- or underestimating the true disease prevalence, and limit efforts to stop the spread of SARS-CoV-2. It is important to conduct in-country validations of serological SARS-CoV-2 assays prior to their widespread use, especially in countries with limited representation in published assay validations.


Subject(s)
Antibodies, Viral/blood , COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/immunology , Immunoglobulin G/blood , SARS-CoV-2/immunology , Spike Glycoprotein, Coronavirus/immunology , Adult , COVID-19/epidemiology , Enzyme-Linked Immunosorbent Assay/methods , Female , Humans , Male , Nigeria/epidemiology , Phosphoproteins/immunology , Sensitivity and Specificity , Seroepidemiologic Studies
5.
J Clin Microbiol ; 59(7): e0051421, 2021 06 18.
Article in English | MEDLINE | ID: mdl-33853839

ABSTRACT

Accurate SARS-CoV-2 serological assays are critical for COVID-19 serosurveillance. However, previous studies have indicated possible cross-reactivity of these assays, including in areas where malaria is endemic. We tested 213 well-characterized prepandemic samples from Nigeria using two SARS-CoV-2 serological assays, Abbott Architect IgG and Euroimmun NCP IgG assay, both targeting SARS-CoV-2 nucleocapsid protein. To assess antibody binding strength, an avidity assay was performed on these samples and on plasma from SARS-CoV-2 PCR-positive persons. Thirteen (6.1%) of 212 samples run on the Abbott assay and 38 (17.8%) of 213 run on the Euroimmun assay were positive. Anti-Plasmodium IgG levels were significantly higher among false positives for both Abbott and Euroimmun; no association was found with active Plasmodium falciparum infection. An avidity assay using various concentrations of urea wash in the Euroimmun assay reduced loosely bound IgG: of 37 positive/borderline prepandemic samples, 46%, 86%, 89%, and 97% became negative using 2 M, 4 M, 5 M, and 8 M urea washes, respectively. The wash slightly reduced avidity of antibodies from SARS-CoV-2 patients within 28 days of PCR confirmation; thereafter, avidity increased for all urea concentrations except 8 M. This validation found moderate to substantial cross-reactivity on two SARS-CoV-2 serological assays using samples from a setting where malaria is endemic. A simple urea wash appeared to alleviate issues of cross-reactivity.


Subject(s)
COVID-19 , Malaria , Antibodies, Viral , Humans , Malaria/diagnosis , Nigeria , SARS-CoV-2 , Sensitivity and Specificity
6.
Afr J Lab Med ; 3(1): 102, 2014.
Article in English | MEDLINE | ID: mdl-29043176

ABSTRACT

BACKGROUND: Proficiency testing (PT) is a means of verifying the reliability of laboratory results, but such programmes are not readily available to laboratories in developing countries. This project provided PT to laboratories in Nigeria. OBJECTIVES: To assess the proficiency of laboratories in the diagnosis of HIV, tuberculosis and malaria. METHODS: This was a prospective study carried out between 2009 and 2011. A structured questionnaire was administered to 106 randomly-selected laboratories. Forty-four indicated their interest in participation and were enrolled. Four rounds of pre-characterised plasma panels for HIV, sputum films for tuberculosis and blood films for malaria were distributed quarterly by courier over the course of one year. The results were returned within two weeks and scores of ≥ 80% were reported as satisfactory. Mentoring was offered after the first and second PT rounds. RESULTS: Average HIV PT scores increased from 74% to 95% from the first round to the third round, but decreased in the fourth round. For diagnosis of tuberculosis, average scores increased from 42% in the first round to 78% in the second round; but a decrease to 34% was observed in the fourth round. Malaria PT performance was 2% at first, but average scores increased between the second and fourth rounds, culminating in a fourth-round score of 39%. Many participants requested training and mentoring. CONCLUSIONS: There were gross deficiencies in the quality of laboratory services rendered across Nigeria. In-country PT programmes, implemented in conjunction with mentoring, will improve coverage and diagnosis of HIV, tuberculosis and malaria.

7.
Afr J Lab Med ; 1(1): 18, 2012.
Article in English | MEDLINE | ID: mdl-29062734

ABSTRACT

ISSUES: Quality-management systems (QMS) are uncommon in clinical laboratories in Nigeria, and until recently, none of the nation's 5 349 clinical laboratories have been able to attain the certifications necessary to begin the process of attaining international accreditation. Nigeria's Human Virology Laboratory (HVL), however, began implementation of a QMS in 2006, and in 2008 it was determined that the laboratory conformed to the requirements of ISO 9001:2000 (now 2008), making it the first diagnostic laboratory to be certified in Nigeria. The HVL has now applied for the World Health Organization (WHO) accreditation preparedness scheme. The experience of the QMS implementation process and the lessons learned therein are shared here. DESCRIPTION: In 2005, two personnel from the HVL spent time studying quality systems in a certified clinical laboratory in Dakar, Senegal. Following this peer-to-peer technical assistance, several training sessions were undertaken by HVL staff, a baseline assessment was conducted, and processes were established. The HVL has monitored its quality indicators and conducted internal and external audits; these analyses (from 2007 to 2009) are presented herein. LESSONS LEARNED: Although there was improvement in the pre-analytical and analytical indicators analysed and although data-entry errors decreased in the post-analytical process, the delay in returning laboratory test results increased significantly. There were several factors identified as causes for this delay and all of these have now been addressed except for an identified need for automation of some high-volume assays (currently being negotiated). Internal and external audits showed a trend of increasing non-conformities which could be the result of personnel simply becoming lax over time. Application for laboratory accreditation, however, could provide the renewed vigour needed to correct these non-conformities. RECOMMENDATION: This experience shows that sustainability of the QMS at present is a cause for concern. However, the tiered system of accreditation being developed by WHO-Afro may act as a driving force to preserve the spirit of continual improvement.

8.
Afr. j. lab. med. (Online) ; 1(1): 1-5, 2012. tab
Article in English | AIM (Africa) | ID: biblio-1257288

ABSTRACT

Issues: Quality-management systems (QMS) are uncommon in clinical laboratories in Nigeria; and until recently; none of the nation's 5 349 clinical laboratories have been able to attain the certifications necessary to begin the process of attaining international accreditation. Nigeria's Human Virology Laboratory (HVL); however; began implementation of a QMS in 2006; and in 2008 it was determined that the laboratory conformed to the requirements of ISO 9001:2000 (now 2008); making it the first diagnostic laboratory to be certified in Nigeria. The HVL has now applied for the World Health Organization (WHO) accreditation preparedness scheme. The experience of the QMS implementation process and the lessons learned there in are shared here. Description: In 2005; two personnel from the HVL spent time studying quality systems in a certified clinical laboratory in Dakar; Senegal. Following this peer-to-peer technical assistance; several training sessions were undertaken by HVL staff; a baseline assessment was conducted; and processes were established. The HVL has monitored its quality indicators and conducted internal and external audits; these analyses (from 2007 to 2009) are presented herein. Lessons learned: Although there was improvement in the pre-analytical and analytical indicators analysed and although data-entry errors decreased in the post-analytical process; the delay in returning laboratory test results increased significantly. There were several factors identified as causes for this delay and all of these have now been addressed except for an identified need for automation of some high-volume assays (currently being negotiated). Internal and external audits showed a trend of increasing non-conformities which could be the result of personnel simply becoming lax over time. Application for laboratory accreditation; however; could provide the renewed vigour needed to correct these non conformities. Recommendation: This experience shows that sustainability of the QMS at present is a cause for concern. However; the tiered system of accreditation being developed by WHO-Afro may act as a driving force to preserve the spirit of continual improvement


Subject(s)
Accreditation , Clinical Laboratory Techniques , Education, Continuing , Nigeria
SELECTION OF CITATIONS
SEARCH DETAIL
...