Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Ther ; 103(12)2023 Dec 06.
Article in English | MEDLINE | ID: mdl-37690060

ABSTRACT

OBJECTIVE: The Avoidance of Daily Activities Photo Scale for Patients With Shoulder Pain (ADAP Shoulder Scale) was developed to assess pain-related avoidance behavior during daily activities in people with shoulder pain. However, its measurement properties must be verified according to international guidelines. As such, this study investigated the following 4 measurement properties of the ADAP Shoulder Scale: reliability, measurement errors, convergent validity, and floor and ceiling effects. METHODS: The sample comprised 100 individuals with chronic shoulder pain (43 men and 57 women; mean duration of symptoms of 29.7 [SD = 89.0] months; mean age of 44.9 [SD = 15.9] years). The mean test-retest reliability range was 5 days via the intraclass correlation coefficient (ICC). Measurement errors included the standard error of measurement and the minimal detectable change. Convergent validity was analyzed by applying the Pearson correlation with the Tampa Scale for Kinesiophobia, Pain Catastrophizing Scale, and Shoulder Pain and Disability Index. RESULTS: The ADAP Shoulder Scale showed excellent test-retest reliability, both in all domains and in the total score [ICC(2,1) = 0.94; 95% CI = 0.92-0.96]. The standard errors of measurement for the free-movement, high-effort, and self-care domains were 8.1%, 6.0%, and 7.6%, respectively. The minimal detectable change for the total score of the ADAP Shoulder Scale was 16.0%. The total score of the ADAP Shoulder Scale was low to moderately correlated with the total scores of the Tampa Scale for Kinesiophobia (r = 0.52), Pain Catastrophizing Scale (r = 0.30), and Shoulder Pain and Disability Index (r = 0.72). No floor or ceiling effects were detected in the total score. CONCLUSION: The ADAP Shoulder Scale is a reliable, valid instrument for assessing avoidance behavior in adults who have chronic shoulder pain and are not athletes. IMPACT: This study provides evidence that the ADAP Shoulder Scale is appropriate for clinical and practical use in people with chronic shoulder pain.


Subject(s)
Shoulder Pain , Adult , Female , Humans , Male , Middle Aged , Avoidance Learning , Disability Evaluation , Psychometrics , Reproducibility of Results , Shoulder , Shoulder Pain/diagnosis , Surveys and Questionnaires , Pain Measurement
2.
Phys Ther ; 102(2)2022 02 01.
Article in English | MEDLINE | ID: mdl-34935976

ABSTRACT

OBJECTIVES: The purpose of this study was to develop the Avoidance of Daily Activities Photo Scale (ADAP Shoulder Scale) to measure shoulder pain-related avoidance behavior in patients with shoulder pain and evaluate and report the structural validity and internal consistency of the scale. METHODS: Potential daily activities involving the shoulder were selected from the activities and participation domain of the International Classification of Functioning, Disability and Health. The selected activities were presented to an expert panel, health care professionals, and patients with shoulder pain with the question "How much do you think it is important to ask patients with shoulder pain about this activity?" Activities attaining a content validity index (CVI) ≥ 0.8 were represented using a digitally colored photograph. Activity photographs were evaluated by health care professionals and patients with shoulder pain. Photographs with a CVI ≥ 0.8 were included in the scale. To evaluate structural validity and internal consistency of the scale, exploratory factor analysis was performed to determine the presence of any scale domain. Cronbach alpha was calculated to indicate the internal consistency of each domain. RESULTS: Of the 107 preselected activities, 21 attained a CVI ≥ 0.8. Eighteen photographs (CVI ≥ 0.8) were included in the scale after being analyzed by 120 health care professionals and 50 patients with shoulder pain. Exploratory factor analysis (N = 156) showed that the ADAP Shoulder Scale consists of 3 domains: free movement, high effort, and self-care. The internal consistencies of the domains were 0.92, 0.89, and 0.92, respectively. CONCLUSION: The ADAP Shoulder Scale included 15 photographs distributed in 3 domains. All domains had a high internal consistency. The scale is easily applicable, well understood, and relevant for shoulder pain. IMPACT: The ADAP Shoulder Scale can be used to rate shoulder pain-related avoidance behaviors.


Subject(s)
Activities of Daily Living/psychology , Avoidance Learning , Behavior Rating Scale/standards , Phobic Disorders/diagnosis , Shoulder Pain/psychology , Adolescent , Adult , Aged , Aged, 80 and over , Disability Evaluation , Factor Analysis, Statistical , Female , Humans , Male , Middle Aged , Photography , Psychometrics , Reproducibility of Results , Young Adult
3.
J Manipulative Physiol Ther ; 44(3): 236-243, 2021 03.
Article in English | MEDLINE | ID: mdl-33926742

ABSTRACT

OBJECTIVE: This study aimed to determine the intra- and interrater reliability of active and passive range of motion in the shoulders of individuals with subacromial impingement syndrome using a digital inclinometer. METHODS: The raters evaluated active and passive range of motion in the shoulder of 50 individuals with unilateral subacromial impingement syndrome in movements including flexion, abduction, extension, external rotation in a neutral position, external rotation with the arm at 90° of abduction, and internal rotation with the arm at 90° of abduction. The tests were performed by 2 examiners on the same day, with a 10-minute interval, and were repeated by 1 examiner after a 2- to 4-day interval. Reliability was analyzed using the intraclass correlation coefficient (ICC2,3). RESULTS: There was moderate to excellent interrater (ICC2,3 = 0.50-0.95) and intrarater (ICC2,3 = 0.74-0.94) reliability. In the interrater analysis, the standard error of measurement (SEM) ranged from 4.1° to 10°, the percentage SEM (%SEM) ranged from 2% to 17%, and the minimum detectable change ranged from 9.5° to 23.4°. In the intrarater analysis, the SEM ranged from 4° to 9.2°, %SEM ranged from 3% to 14%, and the minimum detectable change ranged from 9.3° to 21.4°. CONCLUSION: The digital inclinometer showed moderate to excellent reliability for measuring active and passive range of motion in shoulders with unilateral subacromial impingement syndrome.


Subject(s)
Arthrometry, Articular/standards , Range of Motion, Articular/physiology , Shoulder Impingement Syndrome/physiopathology , Shoulder Joint/physiology , Adult , Arthrometry, Articular/instrumentation , Humans , Male , Movement , Predictive Value of Tests , Reproducibility of Results , Rotation
4.
J Electromyogr Kinesiol ; 24(6): 868-74, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25066517

ABSTRACT

The upper trapezius (UT) has been widely studied and related to alterations in clavicular kinematics in subject with shoulder disorders. However, the most common electrode site used to capture UT EMG is between C7 and the acromion, placing the electrodes over the acromial fibers rather than clavicular ones. Therefore, this study aimed to investigate the relationship between clavicular movements (elevation and retraction) and UT EMG recorded from three electrode sites (traditional electrode positioning and two different sites proposed for clavicular fibers evaluation). Furthermore, the position associated with the highest EMG during maximal isometric voluntary contractions (MVIC), for each electrode site, was determined for normalization purposes. EMG was simultaneously captured in the three electrode sites of 20 healthy subjects, during MVIC at five different positions and during shoulder elevation and abduction in scapular plane. Clavicular kinematics was recorded using an electromagnetic tracking system during the dynamic contractions. Shoulder abduction with head rotation and lateral flexion elicited the highest EMG amplitude on the three electrode sites and was used to normalize the signals. A cross-correlation analysis showed high correlations between all electrode sites and clavicular movements. However, the traditional electrode site seems to record more informative signals in healthy subjects.


Subject(s)
Clavicle/physiology , Electromyography/instrumentation , Electromyography/methods , Isometric Contraction/physiology , Range of Motion, Articular/physiology , Superficial Back Muscles/physiology , Adult , Electrodes , Female , Humans , Male , Movement/physiology , Shoulder/physiology , Shoulder Joint/physiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...