Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters











Publication year range
1.
Ci. Rural ; 41(3)2011.
Article in Portuguese | VETINDEX | ID: vti-707188

ABSTRACT

The objective of this study was to determine the water requirement and the crop coefficients (Kc) values for apple trees cultivated in Vacaria, RS. The study was conducted at the Experimental Station of Temperate Fruits (EEFT) of Embrapa Grape and Wine, located in Vacaria, RS, in plants of the cultivar 'Royal Gala' (Malus domestica) on the rootstock M9. The soil water matric potential values, that were determined employing tensiometers, were used to obtain the soil moisture and the monthly soil water balance. The water consumption of the culture ranged from 0.3mm day-1 to 4.5mm day-1, with an average of 1.9mm day-1. The crop coefficient (Kc) presented a quadratic trend, ranging between 0.19 and 0.88, with mean value of 0.58.


O objetivo do presente trabalho foi determinar a demanda hídrica e os coeficientes de cultura (Kc) para macieiras cultivadas na região de Vacaria, RS. O trabalho foi desenvolvido na Estação Experimental de Fruticultura Temperada (EEFT) da Embrapa Uva e Vinho, localizada em Vacaria, RS, em plantas da cultivar 'Royal Gala' (Malus domestica) sobre porta-enxerto M9. Foram determinados os valores do potencial matricial da água no solo, empregando-se tensiômetros de punção. Com base nesses valores, determinou-se a umidade volumétrica e o balanço hídrico mensal. O consumo hídrico da cultura variou entre 0,3mm dia-1 a 4,5mm dia-1, com média de 1,9mm dia-1. O coeficiente da cultura (Kc) apresentou tendência quadrática, variando entre 0,19 e 0,88, com média igual a 0,58.

2.
Article in Portuguese | LILACS-Express | VETINDEX | ID: biblio-1478523

ABSTRACT

The objective of this study was to determine the water requirement and the crop coefficients (Kc) values for apple trees cultivated in Vacaria, RS. The study was conducted at the Experimental Station of Temperate Fruits (EEFT) of Embrapa Grape and Wine, located in Vacaria, RS, in plants of the cultivar 'Royal Gala' (Malus domestica) on the rootstock M9. The soil water matric potential values, that were determined employing tensiometers, were used to obtain the soil moisture and the monthly soil water balance. The water consumption of the culture ranged from 0.3mm day-1 to 4.5mm day-1, with an average of 1.9mm day-1. The crop coefficient (Kc) presented a quadratic trend, ranging between 0.19 and 0.88, with mean value of 0.58.


O objetivo do presente trabalho foi determinar a demanda hídrica e os coeficientes de cultura (Kc) para macieiras cultivadas na região de Vacaria, RS. O trabalho foi desenvolvido na Estação Experimental de Fruticultura Temperada (EEFT) da Embrapa Uva e Vinho, localizada em Vacaria, RS, em plantas da cultivar 'Royal Gala' (Malus domestica) sobre porta-enxerto M9. Foram determinados os valores do potencial matricial da água no solo, empregando-se tensiômetros de punção. Com base nesses valores, determinou-se a umidade volumétrica e o balanço hídrico mensal. O consumo hídrico da cultura variou entre 0,3mm dia-1 a 4,5mm dia-1, com média de 1,9mm dia-1. O coeficiente da cultura (Kc) apresentou tendência quadrática, variando entre 0,19 e 0,88, com média igual a 0,58.

3.
Sci. agric. ; 60(4)2003.
Article in English | VETINDEX | ID: vti-439826

ABSTRACT

Experimental determination of microsprinkler droplets is difficult and time-consuming. This determination, however, could be achieved using ballistic models. The present study aimed to compare simulated and measured values of microsprinkler droplet diameters. Experimental measurements were made using the flour method, and simulations using a ballistic model adopted by the SIRIAS computational software. Drop diameters quantified in the experiment varied between 0.30 mm and 1.30 mm, while the simulated between 0.28 mm and 1.06 mm. The greatest differences between simulated and measured values were registered at the highest radial distance from the emitter. The model presented a performance classified as excellent for simulating microsprinkler drop distribution.


A determinação experimental dos diâmetros de gotas em sistemas de microaspersão é trabalhosa e demorada. Essa determinação pode, entretanto, ser obtida empregando-se modelos balísticos. O objetivo do presente estudo foi comparar valores medidos experimentalmente com valores simulados de diâmetros de gotas aplicadas por microaspersores. Os dados experimentais foram obtidos empregando-se o método da farinha. As simulações foram realizadas usando o modelo balístico adotado pelo programa computacional SIRIAS. Os diâmetros médios de gotas determinados experimentalmente variaram entre 0,30 mm e 1,30 mm, enquanto que os simulados ficaram entre 0,28 mm e 1,06 mm. As maiores diferenças entre valores medidos e simulados foram registradas nas maiores distâncias em relação ao microaspersor. O modelo apresentou um desempenho classificado como ótimo na simulação da distribuição de gotas em microaspersores.

4.
Sci. agric. ; 60(2)2003.
Article in English | VETINDEX | ID: vti-439744

ABSTRACT

Wind incidence can affect microsprinkler water distribution. Evaluations of those conditions can be facilitated using simulations by computational models. The present work evaluates the performance of a ballistic model on simulating the wind effect on microsprinkler water distribution. Experimental tests were carried out using self-compensating microsprinklers, nozzle sizes 1.00 mm (gray), 1.10 mm (brown), 1.48 mm (orange), and 1.75 mm (yellow). The gray and brown nozzles used black swivels and the orange and yellow nozzles used blue swivels. The wind effect was artificially caused by fourteen 200 W fans. Computational simulations were realized using SIRIAS software, based on a ballistic model originally developed for sprinkler systems. The correlation coefficients (r) varied from 0.619 to 0.880, while the exactness coefficients (d) varied from 0.842 to 0.944. Swivels internal geometry influenced results. Tested models presented performances classified as very good for the black swivel nozzles and regular for the blue swivel nozzles.


A incidência de ventos pode afetar a distribuição da água aplicada por microaspersores. As avaliações nessas condições podem ser facilitadas empregando-se simulações através de modelos computacionais. No presente trabalho avaliou-se o desempenho de um modelo balístico para simular o efeito do vento na distribuição de água em microaspersores. Os ensaios experimentais foram realizados com emissores autocompensantes, com diâmetros de bocais iguais a 1,00 mm (cinza), 1,10 mm (marrom), 1,48 mm (laranja) e 1,75 mm (amarelo). Os bocais cinza e marrom operaram com rotor preto e os bocais laranja e amarelo utilizaram rotor azul. O efeito do vento foi provocado artificialmente empregando-se um conjunto de quatorze ventiladores de 200 W de potência. As simulações computacionais foram realizadas empregando-se o programa SIRIAS, que tem por base um modelo balístico originalmente desenvolvido para sistemas de aspersão convencional. Os coeficientes de correlação (r) variaram de 0,619 a 0,880, enquanto os coeficientes de exatidão (d) ficaram entre 0,842 e 0,944. As geometrias internas dos rotores influenciaram os resultados, sendo que o modelo apresentou um classificado como muito bom para os bocais com rotor preto e um desempenho regular para os bocais que trabalharam com rotor azul.

5.
Sci. agric ; 60(2)2003.
Article in English | LILACS-Express | VETINDEX | ID: biblio-1496300

ABSTRACT

Wind incidence can affect microsprinkler water distribution. Evaluations of those conditions can be facilitated using simulations by computational models. The present work evaluates the performance of a ballistic model on simulating the wind effect on microsprinkler water distribution. Experimental tests were carried out using self-compensating microsprinklers, nozzle sizes 1.00 mm (gray), 1.10 mm (brown), 1.48 mm (orange), and 1.75 mm (yellow). The gray and brown nozzles used black swivels and the orange and yellow nozzles used blue swivels. The wind effect was artificially caused by fourteen 200 W fans. Computational simulations were realized using SIRIAS software, based on a ballistic model originally developed for sprinkler systems. The correlation coefficients (r) varied from 0.619 to 0.880, while the exactness coefficients (d) varied from 0.842 to 0.944. Swivels internal geometry influenced results. Tested models presented performances classified as very good for the black swivel nozzles and regular for the blue swivel nozzles.


A incidência de ventos pode afetar a distribuição da água aplicada por microaspersores. As avaliações nessas condições podem ser facilitadas empregando-se simulações através de modelos computacionais. No presente trabalho avaliou-se o desempenho de um modelo balístico para simular o efeito do vento na distribuição de água em microaspersores. Os ensaios experimentais foram realizados com emissores autocompensantes, com diâmetros de bocais iguais a 1,00 mm (cinza), 1,10 mm (marrom), 1,48 mm (laranja) e 1,75 mm (amarelo). Os bocais cinza e marrom operaram com rotor preto e os bocais laranja e amarelo utilizaram rotor azul. O efeito do vento foi provocado artificialmente empregando-se um conjunto de quatorze ventiladores de 200 W de potência. As simulações computacionais foram realizadas empregando-se o programa SIRIAS, que tem por base um modelo balístico originalmente desenvolvido para sistemas de aspersão convencional. Os coeficientes de correlação (r) variaram de 0,619 a 0,880, enquanto os coeficientes de exatidão (d) ficaram entre 0,842 e 0,944. As geometrias internas dos rotores influenciaram os resultados, sendo que o modelo apresentou um classificado como muito bom para os bocais com rotor preto e um desempenho regular para os bocais que trabalharam com rotor azul.

6.
Sci. agric ; 60(4)2003.
Article in English | LILACS-Express | VETINDEX | ID: biblio-1496384

ABSTRACT

Experimental determination of microsprinkler droplets is difficult and time-consuming. This determination, however, could be achieved using ballistic models. The present study aimed to compare simulated and measured values of microsprinkler droplet diameters. Experimental measurements were made using the flour method, and simulations using a ballistic model adopted by the SIRIAS computational software. Drop diameters quantified in the experiment varied between 0.30 mm and 1.30 mm, while the simulated between 0.28 mm and 1.06 mm. The greatest differences between simulated and measured values were registered at the highest radial distance from the emitter. The model presented a performance classified as excellent for simulating microsprinkler drop distribution.


A determinação experimental dos diâmetros de gotas em sistemas de microaspersão é trabalhosa e demorada. Essa determinação pode, entretanto, ser obtida empregando-se modelos balísticos. O objetivo do presente estudo foi comparar valores medidos experimentalmente com valores simulados de diâmetros de gotas aplicadas por microaspersores. Os dados experimentais foram obtidos empregando-se o método da farinha. As simulações foram realizadas usando o modelo balístico adotado pelo programa computacional SIRIAS. Os diâmetros médios de gotas determinados experimentalmente variaram entre 0,30 mm e 1,30 mm, enquanto que os simulados ficaram entre 0,28 mm e 1,06 mm. As maiores diferenças entre valores medidos e simulados foram registradas nas maiores distâncias em relação ao microaspersor. O modelo apresentou um desempenho classificado como ótimo na simulação da distribuição de gotas em microaspersores.

7.
Sci. agric. ; 59(3)2002.
Article in English | VETINDEX | ID: vti-439654

ABSTRACT

Estimating reference evapotranspiration (ETo) based on Class A pan evaporation (ECA) is very usual in irrigated areas. For this purpose the ECA values are multiplied by a pan coefficient (Kp) to obtain ETo. Kp values can be estimated in different ways being, however, important to know which method would estimate the best value for a given locality. In the present work estimated values of ETo based on Class A pan evaporation, using Kp values determined by different methods, were compared to Penman-Monteith-FAO (EToPM) values for the northwest region of the São Paulo State, Brazil. The annual average Kp, determined dividing EToPM by ECA, was 0.74. For the rainy months (December to March) the average Kp value was 0.80 and for the dry months (April to November) 0.70. The reference evapotranspiration estimated using Kp determined by the Snyder equation presented the best regression coefficients when compared to EToPM.


A estimativa da evapotranspiração de referência (ETo) com base na evaporação do tanque Classe A (ECA) é bastante comum em áreas irrigadas. Para isso multiplica-se o valor de ECA por um coeficiente do tanque (Kp) determinando-se, assim, o valor de ETo. O valor de Kp pode ser determinado de diferentes formas, necessitando-se, contudo, averiguar-se qual a metodologia que propicia a melhor estimativa de ETo a partir de valores de ECA, no local desejado. No presente trabalho foram estimados os valores da evapotranspiração de referência (ETo) para as condições da região noroeste do Estado de São Paulo, a partir de dados do tanque Classe A (ECA), utilizando-se diferentes métodos de determinação do coeficiente do tanque (Kp). Esses valores de ETo foram comparados com os obtidos empregando-se o modelo de Penman-Monteith conforme a parametrização da FAO (EToPM). O valor médio anual de Kp, determinado a partir da relação entre EToPM e ECA, foi de 0,74. No período chuvoso (dezembro a março) o Kp médio foi de, aproximadamente, 0,80 e no período seco (abril a novembro) foi de 0,70. A estimativa da ETo através do tanque Classe A, empregando-se o modelo de Snyder para determinação de Kp, foi a que proporcionou os maiores coeficientes de determinação e de confiança em relação a EToPM.

8.
Sci. agric ; 59(3)2002.
Article in English | LILACS-Express | VETINDEX | ID: biblio-1496209

ABSTRACT

Estimating reference evapotranspiration (ETo) based on Class A pan evaporation (ECA) is very usual in irrigated areas. For this purpose the ECA values are multiplied by a pan coefficient (Kp) to obtain ETo. Kp values can be estimated in different ways being, however, important to know which method would estimate the best value for a given locality. In the present work estimated values of ETo based on Class A pan evaporation, using Kp values determined by different methods, were compared to Penman-Monteith-FAO (EToPM) values for the northwest region of the São Paulo State, Brazil. The annual average Kp, determined dividing EToPM by ECA, was 0.74. For the rainy months (December to March) the average Kp value was 0.80 and for the dry months (April to November) 0.70. The reference evapotranspiration estimated using Kp determined by the Snyder equation presented the best regression coefficients when compared to EToPM.


A estimativa da evapotranspiração de referência (ETo) com base na evaporação do tanque Classe A (ECA) é bastante comum em áreas irrigadas. Para isso multiplica-se o valor de ECA por um coeficiente do tanque (Kp) determinando-se, assim, o valor de ETo. O valor de Kp pode ser determinado de diferentes formas, necessitando-se, contudo, averiguar-se qual a metodologia que propicia a melhor estimativa de ETo a partir de valores de ECA, no local desejado. No presente trabalho foram estimados os valores da evapotranspiração de referência (ETo) para as condições da região noroeste do Estado de São Paulo, a partir de dados do tanque Classe A (ECA), utilizando-se diferentes métodos de determinação do coeficiente do tanque (Kp). Esses valores de ETo foram comparados com os obtidos empregando-se o modelo de Penman-Monteith conforme a parametrização da FAO (EToPM). O valor médio anual de Kp, determinado a partir da relação entre EToPM e ECA, foi de 0,74. No período chuvoso (dezembro a março) o Kp médio foi de, aproximadamente, 0,80 e no período seco (abril a novembro) foi de 0,70. A estimativa da ETo através do tanque Classe A, empregando-se o modelo de Snyder para determinação de Kp, foi a que proporcionou os maiores coeficientes de determinação e de confiança em relação a EToPM.

SELECTION OF CITATIONS
SEARCH DETAIL