Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Cureus ; 16(3): e56198, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38618348

ABSTRACT

There are limited reports about managing knee flexion contracture (KFC) due to hemophilic hemarthrosis with the Ilizarov technique and platelet-rich plasma intraarticular injection administration. This article aims to describe a case of KFC treated with a circular external fixator and intraarticular administration of platelet-rich plasma in a pediatric patient. A 12-year-old male patient suffering from hemophilia A was being monitored by our department due to knee effusions. Extensive knee flexion contracture of the left knee was seen. The Ilizarov technique was chosen for surgical management of the worsening knee flexion contracture. The duration of distraction was six weeks. Due to localized pain and functional impairment, intra-articular administration of platelet-rich plasma (PRP) was applied twice, on the first month after the circular frame removal and at a six-month follow-up, with clinical and functional improvement. Our clinical case report demonstrates that PRP intra-articular injections are likely to provide an improvement in pain and knee joint function, as well as joint hyperemia, even in the case of already established knee flexion contracture, which was managed with a circular distraction device. However, more studies regarding the Ilizarov technique and the PRP intraarticular administration are needed for a protocol to be established for the management of the hemophilic knee joint in the pediatric population.

2.
Int J Cardiol Heart Vasc ; 51: 101383, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38496258

ABSTRACT

Background: Red blood cell distribution width (RDW) is calculated in every blood count test and reflects variability in erythrocyte size. High levels mirror dysregulated erythrocyte homeostasis and have been associated with clonal hematopoiesis as well as higher mortality in several conditions.We aimed to determine the impact of preprocedural RDW levels on functional outcomes after transcatheter aortic valve implantation (TAVI). Methods: In this single-center retrospective study, we analyzed 176 consecutive patients receiving TAVI between 2017 and 2021. RDW upper limit of normal was < 15 %. Patients were stratified according to preprocedural RDW as having normal or elevated values. We assessed all-cause-mortality and a composite endpoint comprising cardiovascular/ valve-related mortality and cardiovascular, valve-related and heart failure hospitalization at 1 year. Results: 43 patients (24.4 %) had RDW ≥ 15 %. There were significant baseline differences between groups (Society of Thoracic Surgeons - Predicted Risk of Mortality score 3.18 %[interquartile range 1.87-5.47] vs. 6.63 %[4.12-10.54] p < 0.001; hemoglobin 13.2 g/dL[11.8-14.1] vs. 10.4 g/dL[9.8-12.2], p < 0.001, RDW-normal vs. RDW-high, respectively). Age was not distinct (80.2 years [77.5-84.1] vs 81.2[71.3-84.7], p = 0.78). 1-year-all-cause mortality was not different (7.9 % vs. 9.4 %, p = 0.79). The RDW-high group showed markedly higher NT-proBNP levels after 1 year (647 ng/ml[283-1265] vs. 1893 ng/ml[744-5109], p = 0.005), and experienced more clinical endpoints (hazard ratio 2.57[1.28-5.16] for the composite endpoint, p = 0.006). RDW remained an independent predictor of the composite endpoint when accounting for all baseline differences in multivariable regression. Conclusion: Elevated preprocedural RDW identifies patients at risk for impaired functional outcome after TAVI and may represent a useful low-cost parameter to guide intensity of outpatient surveillance strategies.

3.
Catheter Cardiovasc Interv ; 102(1): 91-100, 2023 07.
Article in English | MEDLINE | ID: mdl-37194726

ABSTRACT

BACKGROUND: Quantitative flow ratio (QFR) is a novel, software-based method to evaluate the physiology of coronary lesions. The aim of this study was to compare QFR with the established invasive measurements of coronary blood flow using instantaneous wave-free ratio (iFR) or resting full-cycle ratio (RFR) in daily cathlab routine. METHODS: 102 patients with stable coronary artery disease and a coronary stenosis of 40%-90% were simultaneously assessed with QFR and iFR or RFR. QFR-computation was performed by two certified experts using the appropriate software (QAngio XA 3D 3.2). RESULTS: QFR showed a significant correlation (r = 0.75, p < 0.001) to iFR and RFR. The area under the receiver curve for all measurements was 0.93 (95% confidence interval, 0.87-0.98) for QFR compared to iFR or RFR. QFR based assessment required less time with a median of 501 s (IQR 421-659 s) compared to iFR or RFR which required a median of 734 s to obtain the result (IQR 512-967 s; p < 0.001). The median use of contrast medium was similar with 21 mL (IQR 16-30 mL) for the QFR-based and 22 mL (IQR 15-35 mL) for the iFR- or RFR-based diagnostic. QFR diagnostic required less radiation. The median dose area product for QFR was 307cGycm2 (IQR 151-429 cGycm2 ) compared to 599 cGycm2 (IQR 345-1082 cGycm2 ) for iFR or RFR, p < 0.001. CONCLUSION: QFR measurements of coronary artery blood flow correlate with iFR or RFR measurements and are associated with shorter procedure times and reduced radiation dose.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Humans , Coronary Angiography/methods , Predictive Value of Tests , Treatment Outcome , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Cardiac Catheterization , Coronary Vessels/diagnostic imaging , Severity of Illness Index
4.
Int J Cardiovasc Imaging ; 36(8): 1407-1416, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32367188

ABSTRACT

Contrast-flow quantitative flow ratio (cQFR) is a new technology for quantitative evaluation of coronary stenosis using computational fluid dynamics based on angiograms. The aim of this study was to assess the sensitivity and specificity of cQFR to detect myocardial ischemia using stress magnetic resonance imaging (MRI) as a reference standard. Patients who received stress MRI and coronary angiography were selected from the hospital database. Relevant ischemia on stress MRI was defined as a perfusion deficit in ≥ 2 of 16 segments. cQFR was quantitated based on 3-dimensional quantitative coronary angiography using QAngio XA3D1.1 software by two blinded and independent investigators. A cQFR of ≤ 0.80 was considered abnormal. Among 87 patients 230 vessels met the criteria for full analysis by cQFR (88%). In vascular territories with a significant perfusion deficit, cQFR was significantly lower compared to areas with normal perfusion (0.72 (0.62-0.78) vs. 0.96 (0.89-0.99); p < 0.001). The sensitivity of cQFR in detecting significant epicardial stenoses of coronary vessels with documented ischemia in stress MRI was 81% (68-90%), the specificity was 88% (82-92%). Diameter stenoses (DS) and area stenoses (AS) in vessels with positive stress MRI were significantly higher than in vessels without ischemia (DS 59.1% (49.4-68.4%) vs. 34.8% (27.1-46.1%) p < 0.001; AS 75.6% (63.0-85.2%) vs. 45.0% (30.8-63.6%), p < 0.001). The analysis reveals a high correlation between coronary stenosis measured by cQFR and ischemic areas detected by stress MRI. The data set the stage to plan randomized studies assessing cQFR measurements with regard to clinical outcomes.


Subject(s)
Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Circulation , Coronary Stenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Magnetic Resonance Imaging, Cine , Aged , Blood Flow Velocity , Coronary Artery Disease/physiopathology , Coronary Stenosis/physiopathology , Coronary Vessels/physiopathology , Databases, Factual , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Reproducibility of Results , Retrospective Studies , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL
...