Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Sports Med ; 35(14): 1161-9, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25144436

ABSTRACT

This study aimed to compare the oxygen uptake (VO2), the muscle activity of lower limbs, and the vertical ground reaction force (V-GRF) of women performing water aerobic exercises at different intensities. 12 young women performed the experimental protocol, which consisted of 3 water exercises (stationary running [SR], frontal kick [FK] and cross country skiing [CCS]) at 3 intensities (first and second ventilatory thresholds and maximum effort). A two-way repeated measures ANOVA was used. Regarding VO2, different responses between intensities (p<0.001) were found, and values between exercises were similar. For electromyographic activity (EMG), differences between intensities for all muscles (p<0.001) were found. Greater EMG signals were observed in the FK compared to SR for rectus femoris, semitendinosus, vastus lateralis and biceps femoris muscles (p<0.05). Regarding V-GRF, there was an increase in the V-GRF at greater intensities compared to the first ventilatory threshold (p=0.001). In addition, lower values were found during CCS compared to the SR and FK exercises (p<0.001). Thus, greater cardiorespiratory and neuromuscular responses were observed with increasing intensity. Exercises such as CCS could be used to attenuate the V-GRF; if the purpose is to reduce the muscular activity of lower limbs at a specific intensity, SR could be recommended.


Subject(s)
Exercise/physiology , Lower Extremity/physiology , Muscle, Skeletal/physiology , Oxygen Consumption/physiology , Water , Adult , Anaerobic Threshold , Biomechanical Phenomena , Electromyography , Female , Humans , Young Adult
2.
J Sports Med Phys Fitness ; 53(4): 358-67, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23828283

ABSTRACT

AIM: The aim of this study was to compare the cardiorespiratory variables corresponding to the anaerobic threshold (AT) between different water-based exercises using two methods of determining the AT, the heart rate deflection point and ventilatory method, and to correlate the variables in both methods. METHODS: Twenty young women performed three exercise sessions in the water. Maximal tests were performed in the water-based exercises stationary running, frontal kick and cross country skiing. The protocol started at a rate of 80 cycles per minute (cycle.min-1) for 2 min with subsequent increments of 10 cycle.min-1 every minute until exhaustion, with measurements of heart rate, oxygen uptake and ventilation throughout test. After, the two methods were used to determine the values of these variables corresponding to the AT for each of the exercises. Comparisons were made using two-way ANOVA for repeated measures with Bonferroni's post hoc test. To correlate the same variables determined by the two methods, the intra-class correlation coefficient test (ICC) was used. RESULTS: For all the variables, no significant differences were found between the methods of determining the AT and the three exercises. Moreover, the ICC values of each variable determined by the two methods were high and significant. CONCLUSION: The estimation of the heart rate deflection point can be used as a simple and practical method of determining the AT, which can be used when prescribing these exercises. In addition, these cardiorespiratory parameters may be determined performing the test with only one of the evaluated exercises, since there were no differences in the evaluated variables.


Subject(s)
Anaerobic Threshold/physiology , Exercise/physiology , Heart Rate/physiology , Pulmonary Ventilation/physiology , Swimming Pools , Adult , Exercise Test/methods , Female , Humans , Young Adult
3.
Int J Sports Med ; 34(10): 881-7, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23549690

ABSTRACT

The aim of the present study was to compare the peak vertical ground reaction force (V-GRF(peak)) and impulse of women performing water aerobic exercises at different intensities in aquatic and dry land environments. 15 young women performed 1 session in each environment consisting of 3 water aerobic exercises (stationary running, frontal kick and cross country skiing) performed at 3 cadences (first ventilatory threshold, second ventilatory threshold and maximum effort, as determined during exercise in water) in a randomized order. 2-way and 3-way repeated measures ANOVA were used to analyze the impulse and V-GRF(peak), respectively. Significantly lower values of V-GRF(peak) and impulse (p<0.001) were observed for the aquatic environment. Significant differences were observed among all cadences for V-GRF(peak) and impulse (p<0.001) in both environments except for the V-GRF(peak) between the cadences corresponding to the second ventilatory threshold and maximum effort in the aquatic environment. In addition, significantly lower V-GRF(peak) values in the aquatic environment were found for cross country skiing compared to the other exercises (p<0.001). Thus, water exercises are safe for people that need to minimize vertical ground reaction force; however, an important issue to be considered during water aerobics training is the exercise and intensity to be prescribed.


Subject(s)
Exercise/physiology , Water , Adult , Biomechanical Phenomena , Exercise Test , Female , Healthy Volunteers , Humans , Oxygen Consumption
SELECTION OF CITATIONS
SEARCH DETAIL
...