Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Radiol ; 165: 110932, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37390663

ABSTRACT

PURPOSE: Detection of hepatocellular carcinoma (HCC) is crucial during surveillance by ultrasound. We previously developed an artificial intelligence (AI) system based on convolutional neural network for detection of focal liver lesions (FLLs) in ultrasound. The primary aim of this study was to evaluate whether the AI system can assist non-expert operators to detect FLLs in real-time, during ultrasound examinations. METHOD: This single-center prospective randomized controlled study evaluated the AI system in assisting non-expert and expert operators. Patients with and without FLLs were enrolled and had ultrasound performed twice, with and without AI assistance. McNemar's test was used to compare paired FLL detection rates and false positives between groups with and without AI assistance. RESULTS: 260 patients with 271 FLLs and 244 patients with 240 FLLs were enrolled into the groups of non-expert and expert operators, respectively. In non-experts, FLL detection rate in the AI assistance group was significantly higher than the no AI assistance group (36.9 % vs 21.4 %, p < 0.001). In experts, FLL detection rates were not significantly different between the groups with and without AI assistance (66.7 % vs 63.3 %, p = 0.32). False positive detection rates in the groups with and without AI assistance were not significantly different in both non-experts (14.2 % vs 9.2 %, p = 0.08) and experts (8.6 % vs 9.0 %, p = 0.85). CONCLUSIONS: The AI system resulted in significant increase in detection of FLLs during ultrasound examinations by non-experts. Our findings may support future use of the AI system in resource-limited settings where ultrasound examinations are performed by non-experts. The study protocol was registered under the Thai Clinical Trial Registry (TCTR20201230003), which is part of the WHO ICTRP Registry Network. The registry can be accessed via the following URL: https://trialsearch.who.int/Trial2.aspx?TrialID=TCTR20201230003.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Humans , Carcinoma, Hepatocellular/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/pathology , Artificial Intelligence , Prospective Studies , Contrast Media
2.
PLoS One ; 16(6): e0252882, 2021.
Article in English | MEDLINE | ID: mdl-34101764

ABSTRACT

Artificial intelligence (AI) using a convolutional neural network (CNN) has demonstrated promising performance in radiological analysis. We aimed to develop and validate a CNN for the detection and diagnosis of focal liver lesions (FLLs) from ultrasonography (USG) still images. The CNN was developed with a supervised training method using 40,397 retrospectively collected images from 3,487 patients, including 20,432 FLLs (hepatocellular carcinomas (HCCs), cysts, hemangiomas, focal fatty sparing, and focal fatty infiltration). AI performance was evaluated using an internal test set of 6,191 images with 845 FLLs, then externally validated using 18,922 images with 1,195 FLLs from two additional hospitals. The internal evaluation yielded an overall detection rate, diagnostic sensitivity and specificity of 87.0% (95%CI: 84.3-89.6), 83.9% (95%CI: 80.3-87.4), and 97.1% (95%CI: 96.5-97.7), respectively. The CNN also performed consistently well on external validation cohorts, with a detection rate, diagnostic sensitivity and specificity of 75.0% (95%CI: 71.7-78.3), 84.9% (95%CI: 81.6-88.2), and 97.1% (95%CI: 96.5-97.6), respectively. For diagnosis of HCC, the CNN yielded sensitivity, specificity, and negative predictive value (NPV) of 73.6% (95%CI: 64.3-82.8), 97.8% (95%CI: 96.7-98.9), and 96.5% (95%CI: 95.0-97.9) on the internal test set; and 81.5% (95%CI: 74.2-88.8), 94.4% (95%CI: 92.8-96.0), and 97.4% (95%CI: 96.2-98.5) on the external validation set, respectively. CNN detected and diagnosed common FLLs in USG images with excellent specificity and NPV for HCC. Further development of an AI system for real-time detection and characterization of FLLs in USG is warranted.


Subject(s)
Artificial Intelligence , Image Processing, Computer-Assisted/methods , Liver Diseases/diagnosis , Neural Networks, Computer , Ultrasonography/methods , Humans , Liver Diseases/diagnostic imaging , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...