Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Acad Radiol ; 25(3): 391-396, 2018 03.
Article in English | MEDLINE | ID: mdl-29241596

ABSTRACT

Quantitative imaging is increasing in almost all fields of radiological science. Modern quantitative imaging biomarkers measure complex parameters including metabolism, tissue microenvironment, tissue chemical properties or physical properties. In this paper, we focus on measurement reliability assessment in quantitative imaging. We review essential concepts related to measurement such as measurement variability and measurement error. We also discuss reliability study methods for intraobserver and interobserver variability, and the applicable statistical tests including: intraclass correlation coefficient, Pearson correlation coefficient, and Bland-Altman graphs and limits of agreement, standard error of measurement, and coefficient of variation.


Subject(s)
Radiography , Humans , Observer Variation , Reproducibility of Results
2.
Work ; 58(2): 241-247, 2017.
Article in English | MEDLINE | ID: mdl-28922185

ABSTRACT

BACKGROUND: There is a significantly high rate of work-related musculsokeletal injuries in sonography professionals. To date, assessment of risk factors for work- related injuries in sonographers has been based primarily on surveys, subjective reports, and observational methods. There is a need to develop quantitative techniques to better understand risk factors and develop preventive interventions. OBJECTIVE: We pilot tested a high-resolution force-measuring probe capable of precisely measuring forces applied through the transducer by sonographers and used this novel direct measurement technique to evaluate forces during abdominal imaging. METHODS: Twelve sonographers with varied experience, ranging from 1-33 years, performed routine abdominal scans on 10 healthy volunteers who had varied body mass indices (BMI). Imaging was conducted using the force-measuring probe, which provided real-time measurement of forces, and angles. Data were compared by sonographer years of experience and subject BMI. RESULTS: In total, 47 abdominal examinations were performed as part of this study, and all images met standards for clinical diagnostic quality. The mean contact force applied across all exams was 8.2±4.3 Newtons (N) (range: 1.2-36.5 N). For subjects in the high BMI group (BMI>25, n = 4) the mean force was 10.5 N (range: 8.9-13.2 N) compared to 7.9 N (range: 5.9-10.9 N) for subjects with normal BMI (BMI = 18.5-25, n = 6). Similarly, the mean maximum force applied for subjects with high BMI (25.3 N) was significantly higher than force applied for subjects with normal BMI (17.4 N). No significant difference was noted in the amount of force applied by sonographers with more than 5 years of experience (n = 6) at 8.2 N (Range: 5.1-10.0 N) compared to less experienced sonographers (n = 6), whose forces averaged 8.1 N (Range: 5.8-10.0 N). CONCLUSIONS: It is feasible to directly measure forces applied by sonographers using a high-resolution force measurement system. Forces applied during abdominal imaging vary widely, are significantly higher when scanning subjects with high BMI, and are not related to sonographer years of experience. This force measurement system has the potential to provide an additional quantitative data point to explore the impact of applied forces on sonographer related musculoskeletal injury, particularly in conjunction with various body positions, exam types and force durations.


Subject(s)
Occupational Diseases/etiology , Pressure/adverse effects , Radiology , Ultrasonography/adverse effects , Abdomen/diagnostic imaging , Adult , Biomechanical Phenomena , Body Mass Index , Ergonomics/standards , Female , Humans , Male , Middle Aged , Musculoskeletal Diseases/etiology , Pilot Projects , Prospective Studies , Risk Factors , Surveys and Questionnaires , Ultrasonography/methods , Ultrasonography/statistics & numerical data , Workforce
3.
Curr Probl Diagn Radiol ; 46(3): 225-233, 2017.
Article in English | MEDLINE | ID: mdl-28041657

ABSTRACT

Image-guided biopsy and ablation relies on successful identification and targeting of lesions. Currently, image-guided procedures are routinely performed under ultrasound, fluoroscopy, magnetic resonance imaging, or computed tomography (CT) guidance. However, these modalities have their limitations including inadequate visibility of the lesion, lesion or organ or patient motion, compatibility of instruments in an magnetic resonance imaging field, and, for CT and fluoroscopy cases, radiation exposure. Recent advances in technology have resulted in the development of a new generation of navigational guidance tools that can aid in targeting lesions for biopsy or ablations. These navigational guidance tools have evolved from simple hand-held trajectory guidance tools, to electronic needle visualization, to image fusion, to the development of a body global positioning system, to growth in cone-beam CT, and to ablation volume planning. These navigational systems are promising technologies that not only have the potential to improve lesion targeting (thereby increasing diagnostic yield of a biopsy or increasing success of tumor ablation) but also have the potential to decrease radiation exposure to the patient and staff, decrease procedure time, decrease the sedation requirements, and improve patient safety. The purpose of this article is to describe the challenges in current standard image-guided techniques, provide a definition and overview for these next-generation navigational devices, and describe the current limitations of these, still evolving, next-generation navigational guidance tools.


Subject(s)
Ablation Techniques , Image-Guided Biopsy , Patient Care Planning , Radiology, Interventional , Surgery, Computer-Assisted , Humans
4.
J Vasc Interv Radiol ; 27(4): 496-502; quiz 503, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26922977

ABSTRACT

PURPOSE: To evaluate the technique, efficacy, safety, and clinical outcomes of CT-guided microwave ablation of tumors in the hepatic dome. MATERIALS AND METHODS: Retrospective review was conducted of 46 consecutive patients (31 men and 15 women; mean age, 64 y) treated with CT-guided microwave ablation for hepatic-dome tumors between June 2011 and December 2014. Baseline demographics of sex, tumor diagnosis, tumor location, tumor size, and technical details were recorded. Technical success was evaluated. Treatment response was assessed per European Association for the Study of the Liver criteria. Overall success and overall survival were calculated, and complications were recorded. RESULTS: Forty-eight tumors were treated. Tumor locations included segments VIII (n = 32), VII (n = 10), and VIa (n = 6). Mean tumor size was 2.4 cm (range, 0.9-5.2 cm). Thirty-four tumors (70%) were treated following creation of artificial ascites with 0.9% normal saline solution (mean volume, 1,237 mL; range, 300-3,000 mL). The technical success rate was 100%, and the complete response rate was 94%. Overall survival rate was 73.9% over 24.7 months of follow-up. There were no major complications. Two patients experienced small, asymptomatic pneumothoraces that were aspirated at the time of the procedure and required no further treatment. CONCLUSIONS: CT-guided microwave ablation of tumors in the hepatic dome is associated with a high technical success rate, high complete response rate, and low complication rate.


Subject(s)
Carcinoma, Hepatocellular/surgery , Catheter Ablation/methods , Liver Neoplasms/surgery , Microwaves/therapeutic use , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/mortality , Carcinoma, Hepatocellular/pathology , Catheter Ablation/adverse effects , Catheter Ablation/mortality , Female , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/mortality , Liver Neoplasms/pathology , Magnetic Resonance Imaging , Male , Microwaves/adverse effects , Middle Aged , Postoperative Complications/etiology , Predictive Value of Tests , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
5.
AJR Am J Roentgenol ; 206(3): 609-16, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26901019

ABSTRACT

OBJECTIVE: The purpose of this study is to determine the reliability of shear-wave elastographic estimates of the Young modulus in thyroid follicular neoplasms. SUBJECTS AND METHODS: In this study, 35 adults with follicular nodules diagnosed by fine-needle aspiration (FNA) biopsy were enrolled. A single sonographer examined all nodules in three planes (sagittal, transverse, and transverse center). Two raters independently placed ROIs in each nodule. Intra- and interrater reliability were computed as intraclass correlation coefficients (ICCs) and were reported using the Guidelines for Reporting Reliability and Agreement Studies. RESULTS: Thirty-five subjects with 35 follicular pattern nodules diagnosed by FNA biopsy were enrolled; 23 (65.7%) patients were female, with a mean age of 55.1 years (range, 23-85 years). For rater 1, intrarater agreement showed ICCs for single measurements of 0.87, 0.87, and 0.90 in the sagittal, transverse, and transverse center plans, respectively; ICCs for the median of multiple measurements were 0.97, 0.94, and 0.96 in the sagittal, transverse, and transverse center planes, respectively. For rater 2, intrarater agreement showed ICCs for single measurements of 0.94, 0.86, and 0.92 in the sagittal, transverse, and transverse center planes, respectively; ICCs for the median of multiple measurements were 0.97, 0.92, and 0.96 in the sagittal, transverse, and transverse center planes, respectively. Interrater agreement between measurements performed for the same subject showed ICCs for single measurements of 0.87, 0.87, and 0.80 in the sagittal, transverse, and transverse center planes, respectively; ICCs for the median of multiple measurements were 0.96, 0.93, and 0.92 in the sagittal, transverse, and transverse center planes, respectively. CONCLUSION: ROI placement is a reliable method for estimating the Young modulus of tissue in follicular thyroid nodules.


Subject(s)
Adenocarcinoma, Follicular/diagnostic imaging , Elastic Modulus , Elasticity Imaging Techniques , Thyroid Gland/diagnostic imaging , Thyroid Neoplasms/diagnostic imaging , Adenocarcinoma, Follicular/pathology , Adult , Aged , Aged, 80 and over , Biopsy, Fine-Needle , Female , Humans , Male , Middle Aged , Reproducibility of Results , Thyroid Gland/pathology , Thyroid Neoplasms/pathology , Young Adult
6.
Radiographics ; 35(7): 1955-64, 2015.
Article in English | MEDLINE | ID: mdl-26562232

ABSTRACT

Tissue harmonic imaging (THI) is a routinely used component of diagnostic ultrasonography (US). In this method, higher-frequency harmonic waves produced by nonlinear fundamental US wave propagation are used to generate images that contain fewer artifacts than those seen on conventional fundamental wave US tissue imaging. Harmonic frequencies are integer multiples of the fundamental frequency. The majority of current clinical US systems use second harmonic echoes for THI image formation. Image processing techniques (ie, bandwidth receive filtering, pulse inversion, side-by-side phase cancellation, and pulse-coded harmonics) are used to eliminate the fundamental frequency echoes, and the remaining harmonic frequency data are used to generate the diagnostic image. Advantages of THI include improved signal-to-noise ratio and reduced artifacts produced by side lobes, grating lobes, and reverberation. THI has been accepted in US practice, and variations of the technology are available on most US systems typically used for diagnostic imaging in radiologic practice. Differential THI is a further improvement that combines the advantages of THI, including superior tissue definition and reduced speckle artifact, with the greater penetration of lower frequency US, which permits high-quality harmonic imaging at greater depth than could previously be performed with conventional THI.


Subject(s)
Image Enhancement/methods , Ultrasonography/methods , Acoustics , Adult , Female , Humans , Infant , Infant, Newborn , Male , Microbubbles , Signal-To-Noise Ratio , Sound , Subtraction Technique , Transducers
7.
Radiographics ; 35(6): 1789-801, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26466186

ABSTRACT

Diagnostic tests have wide clinical applications, including screening, diagnosis, measuring treatment effect, and determining prognosis. Interpreting diagnostic test results requires an understanding of key statistical concepts used to evaluate test efficacy. This review explains descriptive statistics and discusses probability, including mutually exclusive and independent events and conditional probability. In the inferential statistics section, a statistical perspective on study design is provided, together with an explanation of how to select appropriate statistical tests. Key concepts in recruiting study samples are discussed, including representativeness and random sampling. Variable types are defined, including predictor, outcome, and covariate variables, and the relationship of these variables to one another. In the hypothesis testing section, we explain how to determine if observed differences between groups are likely to be due to chance. We explain type I and II errors, statistical significance, and study power, followed by an explanation of effect sizes and how confidence intervals can be used to generalize observed effect sizes to the larger population. Statistical tests are explained in four categories: t tests and analysis of variance, proportion analysis tests, nonparametric tests, and regression techniques. We discuss sensitivity, specificity, accuracy, receiver operating characteristic analysis, and likelihood ratios. Measures of reliability and agreement, including κ statistics, intraclass correlation coefficients, and Bland-Altman graphs and analysis, are introduced.


Subject(s)
Education, Medical, Continuing , Radiology/education , Statistics as Topic/education , Data Collection , Humans , Radiology/statistics & numerical data , Research Design
8.
BMC Nephrol ; 16: 119, 2015 Jul 31.
Article in English | MEDLINE | ID: mdl-26227484

ABSTRACT

BACKGROUND: There currently is a need for a non-invasive measure of renal fibrosis. We aim to explore whether shear wave elastography (SWE)-derived estimates of tissue stiffness may serve as a non-invasive biomarker that can distinguish normal and abnormal renal parenchymal tissue. METHODS: Participants with CKD (by estimated GFR) and healthy volunteers underwent SWE. Renal elasticity was estimated as Young's modulus (YM) in kilopascals (kPa). Univariate Wilcoxon rank-sum tests were used. RESULTS: Twenty-five participants with CKD (median GFR 38 mL/min; quartile 1, quartile 3 28, 42) and 20 healthy controls without CKD underwent SWE performed by a single radiologist. CKD was associated with increased median YM (9.40 [5.55, 22.35] vs. 4.40 [3.68, 5.70] kPa; p = 0.002) and higher median intra-subject inter-measurement estimated YM's variability (4.27 [2.89, 9.90] vs. 1.51 [1.21, 2.05] kPa; p < 0.001). CONCLUSIONS: SWE-derived estimates of renal stiffness and intra-subject estimated stiffness variability are higher in patients with CKD than in healthy controls. Renal fibrosis is a plausible explanation for the observed difference in YM. Further studies are required to determine the relationship between YM, estimated renal stiffness, and renal fibrosis severity.


Subject(s)
Elastic Modulus , Kidney/diagnostic imaging , Renal Insufficiency, Chronic/diagnostic imaging , Adult , Aged , Case-Control Studies , Cross-Sectional Studies , Elasticity , Elasticity Imaging Techniques , Female , Fibrosis , Humans , Kidney/pathology , Male , Middle Aged , Pilot Projects , Renal Insufficiency, Chronic/pathology
9.
Radiology ; 277(2): 565-73, 2015 Nov.
Article in English | MEDLINE | ID: mdl-25955578

ABSTRACT

PURPOSE: To evaluate the diagnostic accuracy of shear-wave elastography (SWE) for the diagnosis of malignancy in follicular lesions and to identify the optimal SWE measurement plane. MATERIALS AND METHODS: The institutional review board approved this HIPAA-compliant, single-institution, prospective pilot study. Subjects scheduled for surgery after a previous fine-needle aspiration report of "atypia of undetermined significance" or "follicular lesion of undetermined significance," "suspicion for follicular neoplasm," or "suspicion for Hurthle cell neoplasm," were enrolled after obtaining informed consent. Subjects underwent conventional ultrasonography (US), Doppler evaluation, and SWE preoperatively, and their predictive value for thyroid malignancy was evaluated relative to the reference standard of surgical pathologic findings. RESULTS: Thirty-five patients (12 men, 23 women) with a mean age of 55 years (range, 23-85 years) and a fine-needle aspiration diagnosis of atypia of undetermined significance or follicular lesion of undetermined significance (n = 16), suspicion for follicular neoplasm (n = 14), and suspicion for Hurthle cell neoplasm (n = 5) were enrolled in the study. Male sex was a statistically significant (P = .02) predictor of malignancy, but age was not. No sonographic morphologic parameter, including nodule size, microcalcification, macrocalcification, halo sign, taller than wide dimension, or hypoechogenicity, was associated with malignancy. Similarly, no Doppler feature, including intranodular vascularity, pulsatility index, resistive index, or peak-systolic velocity, was associated with malignancy. Higher median SWE tissue Young modulus estimates from the transverse insonation plane were associated with malignancy, yielding an area under the receiver operating characteristic curve of 0.81 (95% confidence interval: 0.62, 1.00) for differentiation of malignant from benign nodules. At a cutoff value of 22.3 kPa, sensitivity, specificity, positive predictive value, and negative predictive value of 82%, 88%, 75%, and 91%, respectively, were observed. CONCLUSION: This prospective pilot study indicates that SWE may be a valuable tool in preoperative malignancy risk assessment of follicular-patterned thyroid nodules.


Subject(s)
Elasticity Imaging Techniques/methods , Thyroid Diseases/diagnostic imaging , Adenocarcinoma, Follicular/diagnostic imaging , Adenocarcinoma, Follicular/pathology , Adenoma/diagnostic imaging , Adenoma/pathology , Adult , Aged , Aged, 80 and over , Biopsy, Fine-Needle , Female , Humans , Male , Middle Aged , Preoperative Care , Prospective Studies , Risk Assessment , Thyroid Diseases/pathology , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology
10.
Abdom Imaging ; 40(4): 709-22, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25750099

ABSTRACT

This article reviews the clinical applications of current ultrasound elastography methods in non-hepatic conditions including thyroid nodules, prostate cancer, chronic kidney disease, solid renal lesions, pancreatic lesions, and deep vein thrombosis. Pathophysiology alters tissue mechanical properties via ultrastructural changes including fibrosis, increased cellularity, bleeding, and necrosis, creating a target biomarker, which can be imaged qualitatively or quantitatively with US elastography. US elastography methods can add information to conventional US methods and improve the diagnostic performance of conventional US in a range of disease processes.


Subject(s)
Elasticity Imaging Techniques , Kidney Diseases/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Thyroid Nodule/diagnostic imaging , Venous Thrombosis/diagnostic imaging , Humans , Kidney/diagnostic imaging , Kidney Neoplasms/diagnostic imaging , Male , Pancreas/diagnostic imaging , Prostate/diagnostic imaging , Renal Insufficiency, Chronic/diagnostic imaging , Sensitivity and Specificity , Thyroid Gland/diagnostic imaging
11.
Abdom Imaging ; 40(4): 698-708, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25690689

ABSTRACT

Ultrasound elastography, also termed sonoelastography, is being used increasingly in clinical practice to aid the diagnosis and management of diffuse liver disease. Elastography has been shown to be capable of differentiating advanced and early-stage liver fibrosis, and consequently a major application in clinical liver care includes progression to cirrhosis risk stratification through (1) assessment of liver fibrosis stage in HCV and HBV patients, (2) distinguishing non-alcoholic steatohepatitis from simple steatosis in non-alcoholic fatty liver disease patients, and (3) prognostic evaluation of liver disease is autoimmune liver disease. In addition, elastographic characterization of focal liver lesions and evaluation of clinically significant portal hypertension have the potential to be clinically useful and are areas of active clinical research.


Subject(s)
Elasticity Imaging Techniques/methods , Liver Diseases/diagnostic imaging , Humans , Liver/diagnostic imaging
12.
Ulus Travma Acil Cerrahi Derg ; 16(4): 308-12, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20849045

ABSTRACT

BACKGROUND: This study aimed to determine the pattern of traumatic lower extremity vascular injuries in Iran. METHODS: Patients with vascular injury of the lower extremity were selected from the Iranian National Trauma Project. This project was conducted in eight major cities during 2000-2004 and consisted of more than 17000 patients. RESULTS: Sixty-three subjects (54 men) with a total of 92 vascular injuries of the lower extremity were identified. Mean age of the patients was 25.87 +/- 13.37 years. Blunt trauma was more frequent than penetrating (62% vs. 38%). In 36 cases (57%), road traffic crash (RTC) was the cause of injury. In 21% of the patients (n=24), vascular injury resulted from occupational trauma. Workers (n=23, 20%) were the most frequently affected group. Three patients (5%) died due to severity of the associated injuries. CONCLUSION: Our results revealed that RTC is the most frequent cause of lower extremity vascular injuries in Iran. Our findings also showed that occupational injuries have considerable prevalence. Establishment of preventive strategies to reduce the frequency of these injuries is recommended.


Subject(s)
Blood Vessels/injuries , Lower Extremity/injuries , Wounds and Injuries/therapy , Adult , Arteries/injuries , Humans , Iran , Length of Stay , Male , Urban Population , Veins/injuries
13.
Int Urol Nephrol ; 42(4): 1041-7, 2010 Dec.
Article in English | MEDLINE | ID: mdl-19798584

ABSTRACT

INTRODUCTION: We evaluated different factors predicting the development of acute pyelonephritis in Iranian children, with special attention to time factor. METHODS: One hundred nineteen patients (93 females and 26 males; age = 32.6 ± 30.8 months) with first urinary tract infection (UTI) were evaluated. None had previous urological problems. Prior to antibiotic therapy blood samples were gathered for laboratory evaluation. Vital signs on admission were measured. Clinical and laboratory indices, including therapeutic delay time (TDT) and therapeutic response time (TRT), were measured. Most patients were evaluated with renal ultrasound in the first three days following admission. All patients underwent dimercaptosuccinic acid (DMSA) renal scintigraphy and 71 were assessed for vesicoureteral reflux (VUR). RESULTS: DMSA scans were abnormal in 77 cases, of which 11 cases had bilateral renal involvement. Mean values for TDT, TRT, leukocyte count (LC), absolute neutrophil count (ANC), erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) were 74.1 h, 39.6 h, 15725 ± 6682 mm(-3), 10772 ± 6458 mm(-3), 51.9 ± 32.5 mm, and 27.3 ± 25.1 mg l(-1), respectively. VUR was present in 29 of 142 evaluated renal units. CONCLUSION: TDT ≥ 48 h, TRT ≥ 24 h, axillary temperature ≥ 39°C, LC ≥ 13500 mm(-3), and age ≥ 18 months predicted abnormal DMSA scan in patients with first episode of UTI. Considerably higher TDT and TRT values of the current study compared to previous ones suggests the more important role of time factor in predicting abnormal DMSA findings in a developing country than in developed ones.


Subject(s)
Kidney Cortex/diagnostic imaging , Pyelonephritis/diagnostic imaging , Pyelonephritis/microbiology , Urinary Tract Infections/diagnostic imaging , Child , Child, Preschool , Female , Humans , Infant , Male , Predictive Value of Tests , Prospective Studies , Radionuclide Imaging , Radiopharmaceuticals , Technetium Tc 99m Dimercaptosuccinic Acid , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...