Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Gan To Kagaku Ryoho ; 47(13): 2035-2037, 2020 Dec.
Article in Japanese | MEDLINE | ID: mdl-33468792

ABSTRACT

To date, neoadjuvant endocrine therapy has shown the same rate of clinical objective response and breast-conserving surgery as neoadjuvant chemotherapy in postmenopausal patients with hormone receptor-positive breast cancer. Moreover, neoadjuvant endocrine therapy is recommended to the patients who are unable to tolerate side effects associated with chemotherapy or who are ineligible for immediate surgery because of their age and comorbidity. We discuss the result of neoadjuvant endocrine therapy in our hospital last 5 years. Nine patients underwent preoperative endocrine therapy between 2015 and 2019. Pathological examinations consisted 7 invasive ductal carcinomas and 2 mucinous carcinomas. The result of preoperative examinations was 7 partial response(PR), 1 complete response(CR), and 1 progress disease(PD). 3 months after initiation, all patients were examined by palpation and US. 6 months after initiation, all patients showed a partial response. These results suggest that neoadjuvant endocrine therapy allows downstaging of tumors and more minimally invasive surgery.


Subject(s)
Breast Neoplasms , Neoadjuvant Therapy , Breast Neoplasms/drug therapy , Hormones , Hospitals , Humans , Postmenopause
2.
Lab Chip ; 16(17): 3340-50, 2016 08 16.
Article in English | MEDLINE | ID: mdl-27440476

ABSTRACT

Integration of solid-state nanopores and multichannel detection of signals from each nanopore are effective measures for realizing high-throughput nanopore sensors. In the present study, we demonstrated fabrication of Si3N4 membrane arrays and the simultaneous measurement of ionic currents through two nanopores formed in two adjacent membranes. Membranes with thicknesses as low as 6.4 nm and small nanopores with diameters of less than 2 nm could be fabricated using the poly-Si sacrificial-layer process and multilevel pulse-voltage injection. Using the fabricated nanopore membranes, we successfully achieved simultaneous detection of clear ionic-current blockades when single-stranded short homopolymers (poly(dA)60) passed through two nanopores. In addition, we investigated the signal crosstalk and leakage current among separated chambers. When two nanopores were isolated on the front surface of the membrane, there was no signal crosstalk or leakage current between the chambers. However, when two nanopores were isolated on the backside of the Si substrate, signal crosstalk and leakage current were observed owing to high-capacitance coupling between the chambers and electrolysis of water on the surface of the Si substrate. The signal crosstalk and leakage current could be suppressed by oxidizing the exposed Si surface in the membrane chip. Finally, the observed ionic-current blockade when poly(dA)60 passed through the nanopore in the oxidized chip was approximately half of that observed in the non-oxidized chip.

SELECTION OF CITATIONS
SEARCH DETAIL
...