Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pathogens ; 10(11)2021 Nov 18.
Article in English | MEDLINE | ID: mdl-34832658

ABSTRACT

In this paper, we investigate the epidemiology of infections-associated Staphylococcusaureus (S. aureus) from the Medical Intensive Care Unit (MICU) at University Hospital Center of Constantine (UHCC) in Algeria, with a special emphasis on methicillin-resistant strains (MRSA) revealed by cefoxitin disks (30 µg), then confirmed by penicillin-binding protein (PBP2a) agglutination and real-time polymerase chain reaction (RT-PCR) targeting mecA and mecC genes. Staphylococcal Cassette Chromosome mec (SCCmec type), staphylococcal protein A (spa-type), multilocus sequence type (MLST), Panton-Valentine Leucocidin (PVL), and toxic shock syndrome toxin-1 (TSST-1) were further investigated in all isolates, and whole genome sequencing was performed for a selected subset of three hospital-acquired MRSA (HA-MRSA) isolates. A measurement of 80% out of the 50 S. aureus isolates were identified as HA-MRSA harbouring the mecA gene, and 72.5% of them were multidrug resistant (MDR). Twelve STs, four different SCCmec cassettes, fourteen spa types, ten isolates Panton-Valentine Leukocidin (PVL)-positive, and three isolates TSST-1 were identified. Interestingly, there was a high prevalence (n = 29; 72.5%) of a worrisome emerging clone: the HA-MRSA ST239/241 SCCmec-III mercury with PVL negative, resistant to ß-lactams, aminoglycosides, quinolones, and tetracyclines. Other clones of HA-MRSA isolates were also identified, including PVL-positive ST80 SCCmec-IV/SCCmec-unknown (22.5%), ST34 SCCmec-V with TSST-1 positive (2.5%), and PVL-negative ST72 SCCmec-II (2.5%). Genome analysis enables us to describe the first detection of both PVL-negative HA-MRSA ST239/241 SCCmec-III mercury carrying ccrC, as well as SCCmec-V cassette, which dramatically changes the epidemiology of S. aureus infections in one of the hospitals in eastern Algeria.

2.
Minerva Anestesiol ; 85(1): 28-33, 2019 01.
Article in English | MEDLINE | ID: mdl-29745622

ABSTRACT

BACKGROUND: Liver transplantation (LT) is a high-risk surgery associated with significant hemodynamic changes requiring advanced hemodynamic monitoring. Pulmonary Artery Catheter (PAC) is still considered as a gold-standard for Cardiac Index (CI) measurement during LT despite association with an increased risk of complications. Noninvasive impedance cardiography (ICG) could be an interesting alternative tool for CI monitoring. The aim of this study was to compare the precision and trending ability of ICG versus PAC methods during LT. METHODS: Patients undergoing LT were prospectively included. CI was measured with PAC and ICG at 4 time points (T1: before surgical incision, T2: during anhepatic phase, T3: after portal reperfusion, T4: during wound closure). Bias and percentage error (PE) between CI measured with PAC and ICG were analyzed with the Bland-Altman method for repeated measurements. Trending ability was studied with 4-quadrant and polar plots and correlation coefficient. RESULTS: We included 43 patients with 156 measures. Mean bias was -0.95 L.min-1.m-2, SD±1.07, limits of agreement -3.73 to 1.83 L.min-1.m-2 and PE 58%. There was a significant increase in bias during LT (P<0.001). Assessment of trending ability displayed a concordance rate of 72% on the 4-quadrant plot and a mean angular bias of -8.4° (SD±28°) and radial limits of agreement ±55° on the polar plot. CONCLUSIONS: CI measurements using ICG exhibited a low precision and a poor trending ability when compared to thermodilution method during LT. Consequently, ICG is not an adequate hemodynamic tool to monitor CI during LT.


Subject(s)
Cardiac Output , Cardiography, Impedance/methods , Liver Transplantation/methods , Pulmonary Artery , Thermodilution/methods , Adult , Aged , Catheterization , Catheterization, Swan-Ganz , Female , Humans , Male , Middle Aged , Monitoring, Intraoperative/methods , Monitoring, Physiologic , Prospective Studies , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...