Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 57
Filter
1.
Cancers (Basel) ; 16(8)2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38672601

ABSTRACT

BACKGROUND: The reproducibility of radiomics features extracted from CT and MRI examinations depends on several physiological and technical factors. The aim was to evaluate the impact of contrast agent timing on the stability of radiomics features using dynamic contrast-enhanced perfusion CT (dceCT) or MRI (dceMRI) in prostate and lung cancers. METHODS: Radiomics features were extracted from dceCT or dceMRI images in patients with biopsy-proven peripheral prostate cancer (pzPC) or biopsy-proven non-small cell lung cancer (NSCLC), respectively. Features that showed significant differences between contrast phases were identified using linear mixed models. An L2-penalized logistic regression classifier was used to predict class labels for pzPC and unaffected prostate regions-of-interest (ROIs). RESULTS: Nine pzPC and 28 NSCLC patients, who were imaged with dceCT and/or dceMRI, were included in this study. After normalizing for individual enhancement patterns by defining seven individual phases based on a reference vessel, 19, 467 and 128 out of 1204 CT features showed significant temporal dynamics in healthy prostate parenchyma, prostate tumors and lung tumors, respectively. CT radiomics-based classification accuracy of healthy and tumor ROIs was highly dependent on contrast agent phase. For dceMRI, 899 and 1027 out of 1118 features were significantly dependent on time after contrast agent injection for prostate and lung tumors. CONCLUSIONS: CT and MRI radiomics features in both prostate and lung tumors are significantly affected by interindividual differences in contrast agent dynamics.

2.
EClinicalMedicine ; 65: 102267, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37876998

ABSTRACT

Background: Ultra-low-dose CT (ULDCT) examinations of the chest at only twice the radiation dose of a chest X-ray (CXR) now offer a valuable imaging alternative to CXR. This trial prospectively compares ULDCT and CXR for the detection rate of diagnoses and their clinical relevance in a low-prevalence cohort of non-traumatic emergency department patients. Methods: In this prospective crossover cohort trial, 294 non-traumatic emergency department patients with a clinically indicated CXR were included between May 2nd and November 26th of 2019 (www.clinicaltrials.gov: NCT03922516). All participants received both CXR and ULDCT, and were randomized into two arms with inverse reporting order. The detection rate of CXR was calculated from 'arm CXR' (n = 147; CXR first), and of ULDCT from 'arm ULDCT' (n = 147; ULDCT first). Additional information reported by the second exam in each arm was documented. From all available clinical and imaging data, expert radiologists and emergency physicians built a compound reference standard, including radiologically undetectable diagnoses, and assigned each finding to one of five clinical relevance categories for the respective patient. Findings: Detection rates for main diagnoses by CXR and ULDCT (mean effective dose: 0.22 mSv) were 9.1% (CI [5.2, 15.5]; 11/121) and 20.1% (CI [14.2, 27.7]; 27/134; P = 0.016), respectively. As an additional imaging modality, ULDCT added 9.1% (CI [5.2, 15.5]; 11/121) of main diagnoses to prior CXRs, whereas CXRs did not add a single main diagnosis (0/134; P < 0.001). Notably, ULDCT also offered higher detection rates than CXR for all other clinical relevance categories, including findings clinically irrelevant for the respective emergency department visit with 78.5% (CI [74.0, 82.5]; 278/354) vs. 16.2% (CI [12.7, 20.3]; 58/359) as a primary modality and 68.2% (CI [63.3, 72.8]; 245/359) vs. 2.5% (CI [1.3, 4.7]; 9/354) as an additional imaging modality. Interpretation: In non-traumatic emergency department patients, ULDCT of the chest offered more than twice the detection rate for main diagnoses compared to CXR. Funding: The Department of Biomedical Imaging and Image-guided Therapy of Medical University of Vienna received funding from Siemens Healthineers (Erlangen, Germany) to employ two research assistants for one year.

3.
JTCVS Open ; 10: 62-72, 2022 Jun.
Article in English | MEDLINE | ID: mdl-36004247

ABSTRACT

Objectives: The ratio of pulmonary artery (PA) and ascending aorta (AA) diameters has recently been shown to be a useful indicator for disease severity and predictor of outcome in patients with pulmonary hypertension and heart failure. This study aimed at evaluating the applicability of this ratio for perioperative risk assessment of patients with chronic thromboembolic pulmonary hypertension undergoing pulmonary endarterectomy. Methods: In this retrospective cohort study on 149 patients undergoing pulmonary endarterectomy between 2013 and 2020, the preoperative PA to AA ratio was analyzed on axial computed tomography. Variables of pulmonary hemodynamic status were assessed during preoperative right heart catheterization and postoperative Swan-Ganz catheter measurements. Perioperative survival was analyzed by Kaplan-Meier method and log-rank tests. Results: Preoperative computed tomography measurements showed a median AA diameter of 31 mm (range, 19-47 mm), and a median PA diameter of 36 mm (range, 25-55 mm). The calculated median PA to AA ratio was 1.13 (range, 0.79-1.80). PA to AA ratio correlated positively with PA pressure (systolic, r = 0.352 [P < .001]; diastolic, r = 0.406 [P < .001]; mean, r = 0.318 [P < .001]) and inversely with age (r = -0.484 [P < .001]). Univariable Cox regression analysis identified PA diameter (P = .008) as a preoperative parameter predictive of survival. There was a significant difference (log-rank P = .037) in 30-day survival probability for patients with lower PA to AA ratios (<1.136; survival probability, 97.4%) compared with patients with higher ratios (>1.136; survival probability, 88.9%). Conclusions: PA to AA ratio shows a correlation with other variables associated with pulmonary hypertension. In addition, patients with higher PA to AA ratios have lower survival probabilities after PEA. Further analysis of PA to AA ratio on the selection of chronic thromboembolic pulmonary hypertension for different treatment modalities-pulmonary endarterectomy, medical therapy, and or balloon pulmonary angioplasty-is warranted.

5.
In Vivo ; 36(3): 1354-1359, 2022.
Article in English | MEDLINE | ID: mdl-35478124

ABSTRACT

BACKGROUND/AIM: Various neurological disorders are associated with lesions predominantly or exclusively affecting the splenium of the corpus callosum (CC), such as Marchiafava-Bignami syndrome (MBS), reversible splenium lesion (RSL), and ischemic stroke (IS). The spectrum of symptoms is broad and clinical presentations may be indistinguishable. Therefore, we aimed to investigate the additional value of diffusion-weighted imaging (DWI) findings of splenial lesions in patients with MBS, RSL, and IS. PATIENTS AND METHODS: Overall, 23 patients (4 patients with MBS, 10 patients with RSL, and 9 patients with isolated IS in the splenium) were identified from a magnetic resonance imaging report database and analyzed with focus on lesion localization, shape, and size on DWI, as well as relative apparent diffusion coefficient (ADC). RESULTS: A focal hyperintensity in the splenium was observed on DWI in all patients. In MBS symmetrical boomerang-shaped lesions, in RSL central oval or round lesions, and in IS eccentric irregular lesions in the splenium were found. The median lesion size in MBS [6.25 (IQR=2.04-8.62) ml] was significantly larger than that in RSL [0.38 (IQR=0.09-0.92) ml, p=0.01], and in IS [0.09 (IQR=0.05-0.94) ml; p=0.01]. Regarding relative ADC values, no significant differences between MBS [0.32 (IQR=0.19-0.62)], RSL [0.22 (IQR=0.14-0.30)], and IS [0.27 (IQR=0.20-1.19)] were found. CONCLUSION: Diffusion restricted lesions in the splenium of the CC are best classified by localization, shape, and size, whereas relative ADC values are of limited value for differentiation of different neurological disorders.


Subject(s)
Brain Diseases , Corpus Callosum , Brain Diseases/pathology , Corpus Callosum/diagnostic imaging , Corpus Callosum/pathology , Diffusion Magnetic Resonance Imaging/methods , Humans
6.
Front Oncol ; 11: 637804, 2021.
Article in English | MEDLINE | ID: mdl-33889546

ABSTRACT

Background: Immune checkpoint inhibitor efficacy in advanced cancer patients remains difficult to predict. Imaging is the only technique available that can non-invasively provide whole body information of a patient's response to treatment. We hypothesize that quantitative whole-body prognostic information can be extracted by leveraging artificial intelligence (AI) for treatment monitoring, superior and complementary to the current response evaluation methods. Methods: To test this, a cohort of 74 stage-IV urothelial cancer patients (37 in the discovery set, 37 in the independent test, 1087 CTs), who received anti-PD1 or anti-PDL1 were retrospectively collected. We designed an AI system [named prognostic AI-monitor (PAM)] able to identify morphological changes in chest and abdominal CT scans acquired during follow-up, and link them to survival. Results: Our findings showed significant performance of PAM in the independent test set to predict 1-year overall survival from the date of image acquisition, with an average area under the curve (AUC) of 0.73 (p < 0.001) for abdominal imaging, and 0.67 AUC (p < 0.001) for chest imaging. Subanalysis revealed higher accuracy of abdominal imaging around and in the first 6 months of treatment, reaching an AUC of 0.82 (p < 0.001). Similar accuracy was found by chest imaging, 5-11 months after start of treatment. Univariate comparison with current monitoring methods (laboratory results and radiological assessments) revealed higher or similar prognostic performance. In multivariate analysis, PAM remained significant against all other methods (p < 0.001), suggesting its complementary value in current clinical settings. Conclusions: Our study demonstrates that a comprehensive AI-based method such as PAM, can provide prognostic information in advanced urothelial cancer patients receiving immunotherapy, leveraging morphological changes not only in tumor lesions, but also tumor spread, and side-effects. Further investigations should focus beyond anatomical imaging. Prospective studies are warranted to test and validate our findings.

7.
Clin Neuroradiol ; 31(3): 827-831, 2021 Sep.
Article in English | MEDLINE | ID: mdl-32865598

ABSTRACT

PURPOSE: Occlusion or significant stenosis of the internal carotid artery (ICA) in the cervical segment is commonly associated with a poststenotic decrease in the downstream blood flow and perfusion. Fluid attenuated inversion recovery (FLAIR) vascular hyperintensities (FVH) are a phenomenon that represents slow arterial blood flow. In this study, we investigated the frequency and extent of FVH in the distal ICA in patients with proximal ICA stenosis. METHODS: We analyzed the magnetic resonance imaging (MRI) findings in 51 patients with a total of 60 cervical ICA stenoses with special focus on the frequency and extent of FVH in the area of the petrous segment of the ICA on FLAIR images and correlated these with Doppler/duplex sonography results. RESULTS: In 46 (76.7%) patients with ICA stenosis, FVH could be detected in the petrous segment of the ICA: in 19 (41.3%) patients a thin hyperintense rim near the vessel wall (grade 1), in 24 (52.2%) patients a strong hyperintense rim near the vessel wall (grade 2), and in 3 (6.5%) patients a hyperintense filling of the entire lumen (grade 3) was observed. The extent of FVH in the ICA in the petrous segment showed a high negative correlation with the poststenotic flow velocity (Spearman correlation, R = -0.75, p < 0.001), and moderate correlation with the degree of ICA stenosis (Spearman correlation, R = 0.51, p< 0.001). CONCLUSION: An FVH in the petrous ICA is commonly seen among patients with steno-occlusive disease in proximal ICA and could therefore be useful to recognize a proximal ICA stenosis even on FLAIR images.


Subject(s)
Carotid Stenosis , Magnetic Resonance Angiography , Carotid Stenosis/diagnostic imaging , Constriction, Pathologic , Hemodynamics , Humans , Magnetic Resonance Imaging
8.
PLoS One ; 15(2): e0228376, 2020.
Article in English | MEDLINE | ID: mdl-32023294

ABSTRACT

OBJECTIVES: The purpose of this study was to investigate the impact of a 150kV spectral filtration chest imaging protocol (Sn150kVp) combined with advanced modeled iterative reconstruction (ADMIRE) on radiation dose and image quality in patients after lung-transplantation. METHODS: This study included 102 patients who had unenhanced chest-CT examinations available on both, a second-generation dual-source CT (DSCT) using standard protocol (100kVp, filtered-back-projection) and, on a third-generation DSCT using Sn150kVp protocol with ADMIRE. Signal-to-noise-ratio (SNR) was measured in 6 standardized regions. A 5-point Likert scale was used to evaluate subjective image quality. Radiation metrics were compared. RESULTS: The mean time interval between the two acquisitions was 1.1±0.7 years. Mean-volume-CT-dose-index, dose-length-product and effective dose were significantly lower for Sn150kVp protocol (2.1±0.5mGy;72.6±16.9mGy*cm;1.3±0.3mSv) compared to 100kVp protocol (6.2±1.8mGy;203.6±55.6mGy*cm;3.7±1.0mSv) (p<0.001), equaling a 65% dose reduction. All studies were considered of diagnostic quality. SNR measured in lung tissue, air inside trachea, vertebral body and air outside the body was significantly higher in 100kVp protocol compared to Sn150kVp protocol (12.5±2.7vs.9.6±1.5;17.4±3.6vs.11.8±1.8;0.7±0.3vs.0.4±0.2;25.2±6.9vs.14.9±3.3;p<0.001). SNR measured in muscle tissue was significantly higher in Sn150kVp protocol (3.2±0.9vs.2.6±1.0;p<0.001). For SNR measured in descending aorta there was a trend towards higher values for Sn150kVp protocol (2.8±0.6 vs. 2.7±0.9;p = 0.3). Overall SNR was significantly higher in 100kVp protocol (5.0±4.0vs.4.0±4.0;p<0.001). On subjective analysis both protocols achieved a median Likert rating of 1 (25th-75th-percentile:1-1;p = 0.122). Interobserver agreement was good (intraclass correlation coefficient = 0.73). CONCLUSIONS: Combined use of 150kVp tin-filtered chest CT protocol with ADMIRE allows for significant dose reduction while maintaining highly diagnostic image quality in the follow up after lung transplantation when compared to a standard chest CT protocol using filtered back projection.


Subject(s)
Image Processing, Computer-Assisted/methods , Lung Diseases/diagnostic imaging , Lung Transplantation/methods , Radiographic Image Enhancement/instrumentation , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Algorithms , Female , Humans , Lung Diseases/surgery , Male , Middle Aged , Radiation Dosage , Radiographic Image Enhancement/methods , Retrospective Studies , Signal-To-Noise Ratio , Tin
9.
World J Urol ; 38(11): 2971-2979, 2020 Nov.
Article in English | MEDLINE | ID: mdl-31993735

ABSTRACT

PURPOSE: To assess a novel low-dose CT-protocol, combining a 150 kV spectral filtration unenhanced protocol (Sn150 kVp) and a stone-targeted dual-energy CT (DECT) in patients with urolithiasis. METHODS: 232 (151 male, 49 ± 16.4 years) patients with urolithiasis received a low-dose non-contrast enhanced CT (NCCT) for suspected urinary stones either on a third-generation dual-source CT system (DSCT) using Sn150 kVp (n = 116, group 1), or on a second-generation DSCT (n = 116 group 2) using single energy (SE) 120 kVp. For group 1, a subsequent dual-energy CT (DECT) with a short stone-targeted scan range was performed. Objective and subjective image qualities were assessed. Radiation metrics were compared. RESULTS: 534 stones (group 1: n = 242 stones; group 2: n = 292 stones) were found. In group 1, all 215 stones within the stone-targeted DECT-scan range were identified. DE analysis was able to distinguish between UA and non-UA calculi in all collected stones. 11 calculi (5.12%) were labeled as uric acid (UA) while 204 (94.88%) were labeled as non-UA calculi. There was no significant difference in overall Signal-to-noise-ratio between group 1 and group 2 (p = 0.819). On subjective analysis both protocols achieved a median Likert rating of 2 (p = 0.171). Mean effective dose was significantly lower for combined Sn150 kVp and stone-targeted DECT (3.34 ± 1.84 mSv) compared to single energy 120 kVp NCCT (4.45 ± 2.89 mSv) (p < 0.001), equaling a 24.9% dose reduction. CONCLUSION: The evaluated novel low-dose stone composition protocol allows substantial radiation dose reduction with consistent high diagnostic image quality.


Subject(s)
Tomography, X-Ray Computed/methods , Urinary Calculi/diagnostic imaging , Adult , Aged , Female , Humans , Male , Middle Aged , Radiation Dosage , Retrospective Studies
10.
PLoS One ; 14(12): e0225673, 2019.
Article in English | MEDLINE | ID: mdl-31856177

ABSTRACT

PURPOSE: Advanced forms of prostate cancer (PCa) radiotherapy with either external beam therapy or brachytherapy delivery techniques aim for a focal boost and thus require accurate lesion localization and lesion segmentation for subsequent treatment planning. This study prospectively evaluated dynamic contrast-enhanced computed tomography (DCE-CT) for the detection of prostate cancer lesions in the peripheral zone (PZ) using qualitative and quantitative image analysis compared to multiparametric magnet resonance imaging (mpMRI) of the prostate. METHODS: With local ethics committee approval, 14 patients (mean age, 67 years; range, 57-78 years; PSA, mean 8.1 ng/ml; range, 3.5-26.0) underwent DCE-CT, as well as mpMRI of the prostate, including standard T2, diffusion-weighted imaging (DWI), and DCE-MRI sequences followed by transrectal in-bore MRI-guided prostate biopsy. Maximum intensity projections (MIP) and DCE-CT perfusion parameters (CTP) were compared between healthy and malignant tissue. Two radiologists independently rated image quality and the tumor lesion delineation quality of PCa using a five-point ordinal scale. MIP and CTP were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. RESULTS: The PCa detection rate ranged between 57 to 79% for the two readers for DCE-CT and was 92% for DCE-MRI. DCE-CT perfusion parameters in PCa tissue in the PZ were significantly different compared to regular prostate tissue and benign lesions. Image quality and lesion visibility were comparable between DCE-CT and DCE-MRI (VGC: AUC 0.612 and 0.651, p>0.05). CONCLUSION: Our preliminary results suggest that it is feasible to use DCE-CT for identification and visualization, and subsequent segmentation for focal radiotherapy approaches to PCa.


Subject(s)
Four-Dimensional Computed Tomography/methods , Perfusion Imaging/methods , Prostatic Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Aged , Biopsy, Large-Core Needle , Contrast Media/administration & dosage , Diffusion Magnetic Resonance Imaging , Feasibility Studies , Humans , Image-Guided Biopsy , Male , Middle Aged , Neoplasm Grading , Proof of Concept Study , Prospective Studies , Prostate/diagnostic imaging , Prostate/pathology , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Radiation Dosage
11.
Eur Radiol ; 29(7): 3617-3625, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30888484

ABSTRACT

OBJECTIVES: The aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC). METHODS: This retrospective, institutional review board-approved study included 45 patients (18 male, 27 female; mean age 66 years; range, 42-96 years) with PDAC who had undergone a dual-energy CT (DECT) of the abdomen for staging. One standard polyenergetic image (PEI) and five MEI(+) images in 10-keV intervals, ranging from 40 to 80 keV, were reconstructed. Line-density profile analysis, as well as the contrast-to-noise ratio (CNR) of the tumor, the signal-to-noise ratio (SNR) of the regular pancreas parenchyma and the tumor, and the CNR of the three main peripancreatic vessels, was calculated. For subjective quality assessment, two readers independently assessed the images using a 5-point Likert scale. Reader reliability was evaluated using an intraclass correlation coefficient. RESULTS: Line-density profile analysis revealed the largest gradient in attenuation between PDAC and regular tissue in MEI(+) at 40 keV. Low-keV MEI(+)reconstructions at 40 and 50 keV increased CNR and SNR compared to PEI (40 keV: CNR 46.8 vs. 7.5; SNRPankreas 32.5 vs. 15.7; SNRLesion 13.5 vs. 8.6; p < 0.001). MEI(+) at 40 keV and 50 keV were consistently preferred by the observers (p < 0.05), showing a high intra-observer 0.937 (0.92-0.95) and inter-observer 0.911 (0.89-0.93) agreement. CONCLUSION: MEI(+) reconstructions at 40 keV and 50 keV provide better objective and subjective image quality compared to conventional PEI of DECT in patients with PDAC. KEY POINTS: • Low-keV MEI(+) reconstructions at 40 and 50 keV increase tumor-to-pancreas contrast compared to PEI. • Low-keV MEI(+) reconstructions improve objective and subjective image quality parameters compared to PEI. • Dual-energy post-processing might be a valuable tool in the diagnostic workup of patients with PDAC.


Subject(s)
Algorithms , Carcinoma, Pancreatic Ductal/diagnosis , Image Processing, Computer-Assisted/methods , Pancreas/diagnostic imaging , Pancreatic Neoplasms/diagnosis , Radiography, Dual-Energy Scanned Projection/methods , Virtual Reality , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies
12.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1552-1561, 2019 May.
Article in English | MEDLINE | ID: mdl-29881885

ABSTRACT

PURPOSE: To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. METHODS: Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. RESULTS: The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. CONCLUSIONS: Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.


Subject(s)
Arthroplasty, Replacement, Knee , Artifacts , Metals/chemistry , Radiographic Image Interpretation, Computer-Assisted , Titanium/chemistry , Ceramics/chemistry , Chromium Alloys/chemistry , Coated Materials, Biocompatible/chemistry , Computer Simulation , Humans , Phantoms, Imaging , Prostheses and Implants , Reproducibility of Results , Tomography, X-Ray Computed
13.
Eur Radiol ; 28(11): 4766-4774, 2018 Nov.
Article in English | MEDLINE | ID: mdl-29761359

ABSTRACT

OBJECTIVES: To assess whether electronic cleansing (EC) of tagged residue and different computed tomography (CT) windows influence the size of colorectal polyps in CT colonography (CTC). METHODS: A database of 894 colonoscopy-validated CTC datasets of a low-prevalence cohort was retrospectively reviewed to identify patients with polyps ≥6 mm that were entirely submerged in tagged residue. Ten radiologists independently measured the largest diameter of each polyp, two-dimensionally, before and after EC in colon, bone, and soft-tissue-windows, in randomised order. Differences in size and polyp count before and after EC were calculated for size categories ≥6 mm and ≥10 mm. Statistical testing involved 95% confidence interval, intraclass correlation and mixed-model ANOVA. RESULTS: Thirty-seven patients with 48 polyps were included. Mean polyp size before EC was 9.8 mm in colon, 9.9 mm in bone and 8.2 mm in soft-tissue windows. After EC, the mean polyp size decreased significantly to 9.4 mm in colon, 9.1 mm in bone and 7.1 mm in soft-tissue windows. Compared to unsubtracted colon windows, EC, performed in colon, bone and soft-tissue windows, led to a shift of 6 (12,5%), 10 (20.8%) and 25 (52.1%) polyps ≥6 mm into the next smaller size category, thus affecting patient risk stratification. CONCLUSIONS: EC and narrow CT windows significantly reduce the size of polyps submerged in tagged residue. Polyp measurements should be performed in unsubtracted colon windows. KEY POINTS: • EC significantly reduces the size of polyps submerged in tagged residue. • Abdominal CT-window settings significantly underestimate 2D sizes of submerged polyps. • Size reduction in EC is significantly greater in narrow than wide windows. • Underestimation of polyp size due to EC may lead to inadequate treatment. • Polyp measurements should be performed in unsubtracted images using a colon window.


Subject(s)
Colonic Polyps/diagnostic imaging , Colonography, Computed Tomographic/methods , Image Processing, Computer-Assisted/methods , Aged , Algorithms , Analysis of Variance , Colonography, Computed Tomographic/standards , Female , Humans , Male , Middle Aged , Reference Standards , Retrospective Studies , Sensitivity and Specificity
15.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29404770

ABSTRACT

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Subject(s)
Calcinosis/diagnostic imaging , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Calcium , Female , Filtration/methods , Humans , Male , Middle Aged , Prognosis , Prospective Studies , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Risk Assessment/methods , Tin
16.
J Cardiovasc Comput Tomogr ; 11(3): 183-187, 2017.
Article in English | MEDLINE | ID: mdl-28431860

ABSTRACT

BACKGROUND: To determine the predictive value of volumetrically measured lung perfusion defects (PDvol) and right ventricular dysfunction on dual-energy computed tomography angiography (DE-CTA) for predicting all cause mortality in patients suspected of pulmonary embolism (PE) but without evident thromboembolic clot on CTA. METHODS: 448 patients underwent DE-CTA on a 64-channel DSCT system between January 2007 and December 2012 for suspected PE, of which 115 were without detectable thromboembolic clot on CTA. Diagnostic performance for identifying patients at risk of dying was evaluated using ROC analysis. All-cause mortality was assessed via the hospital electronic medical records and/or consultation of the patient or the patient's primary care physician via phone call interviews. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and area under the curve (AUC) were determined for PDvol (volume of perfusion defects/total lung volume), transverse right ventricular to left ventricular diameter ratios (RV/LV) and for the combination of both tests. RESULTS: Mortality was 38% within the investigated time period of 6 months. Patients who died had significantly higher PDvol (PDvol 28 ± 13% vs. 19 ± 12%, p < 0.001) and a non-significant difference in transverse RV/LV ratio (1.14 ± 0.37 vs. 1.06 ± 0.22, p = 0.159). The AUC was 0.71 for PDvol, 0.53 for RV/LV ratio, and 0.67 for the combination of PDvol and RV/LV ratio. PDvol remained a significant predictor after correcting for age. CONCLUSIONS: In the absence of thromboembolic clots, PDvol at DE-CTA appears to be predictive for all cause mortality.


Subject(s)
Computed Tomography Angiography , Multidetector Computed Tomography , Perfusion Imaging/methods , Pulmonary Circulation , Pulmonary Embolism/diagnostic imaging , Adult , Aged , Aged, 80 and over , Area Under Curve , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Pulmonary Embolism/mortality , Pulmonary Embolism/physiopathology , ROC Curve , Reproducibility of Results , Retrospective Studies , Risk Factors , Time Factors , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/mortality , Ventricular Dysfunction, Right/physiopathology , Ventricular Function, Left , Ventricular Function, Right
17.
Int J Cardiovasc Imaging ; 33(9): 1425-1431, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28342038

ABSTRACT

The purpose of the current study is to investigate whether breast cancer survivors after radiation therapy have a higher burden of coronary artery calcium as a potential surrogate of radiation-induced accelerated coronary artery disease. 333 patients were included. 54 patients underwent chest CT ≥ 6 months after the start of radiation therapy (radiation therapy group), while 279 patients had a CT scan either prior to or without undergoing radiation therapy (RT). Coronary artery calcium was quantified from CT by applying a threshold-based automated algorithm. Mean age at diagnosis was similar (p = 0.771) between RT (57.4 ± 13.1 years) and NoRT (58.0 ± 11.9 years). Median time between radiation therapy and CT was 2 years. The groups showed no significant differences in race, smoking history, cancer laterality, or cancer stage. 39 (72.2%) of RT patients had a coronary artery calcium score of 0, compared to 201 (72.0%) in patients without radiation therapy. Median coronary artery calcium burden for both groups was not significantly different (p = 0.982), nor when comparing patients who underwent left- versus right-sided radiation therapy (p = 0.453). When adjusting for the time between diagnosis and CT, radiation therapy patients had a significantly lower risk of a positive coronary artery calcium score. In conclusion, breast cancer survivors after radiation therapy are not more likely to show coronary artery calcium on follow-up CT imaging. Our results thus do not support radiation-induced accelerated coronary artery disease as an explanation for higher rates of heart disease in this group.


Subject(s)
Breast Neoplasms/radiotherapy , Cancer Survivors , Computed Tomography Angiography , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Vascular Calcification/diagnostic imaging , Adult , Aged , Algorithms , Coronary Artery Disease/etiology , Coronary Vessels/radiation effects , Female , Humans , Middle Aged , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Radiotherapy/adverse effects , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Vascular Calcification/etiology
18.
Am J Cardiol ; 119(8): 1156-1161, 2017 Apr 15.
Article in English | MEDLINE | ID: mdl-28233536

ABSTRACT

The aim of this study was to assess the image quality (IQ) and radiation dose of third-generation dual-source computed tomography (CT) coronary angiography (cCTA) in comparison with 64-slice single-source CT. This retrospective study included 140 patients (73 men, mean age 62 ± 11 years) with low-to-intermediate probability of coronary artery disease who underwent either third-generation dual-source cCTA using prospectively electrocardiography-triggered high-pitch spiral acquisition (n = 70) (group 1) or retrospective electrocardiography-gated cCTA on a 64-slice CT system (n = 70) (group 2). Contrast-to-noise and signal-to-noise ratios were measured within the aorta and coronary arteries. Subjective IQ was assessed using a 5-point Likert scale. Effective dose was estimated using specific conversion factors. The contrast-to-noise ratio of group 1 was significantly higher than group 2 at all levels (all p <0.001). Signal-to-noise ratio of group 1 was also significantly higher than group 2 (p <0.05), except for the distal left circumflex artery. Subjective IQ for group 1 was rated significantly better than for group 2 (median score [25th to 75th percentile]: 1 [1 to 2] vs 2 [2 to 3]; p <0.001). The median effective dose was 1.55 mSv (1.09 to 1.88) in group 1 versus 12.29 mSv (11.63 to 14.36) in group 2 (p <0.001) which corresponds to a mean radiation dose reduction of 87.4%. In conclusion, implementation of third-generation dual-source CT system for cCTA leads to improved IQ with significant radiation dose savings.


Subject(s)
Cardiac-Gated Imaging Techniques , Coronary Angiography/methods , Radiation Dosage , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Coronary Artery Disease/diagnostic imaging , Electrocardiography , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Retrospective Studies
19.
Eur J Radiol ; 86: 163-168, 2017 Jan.
Article in English | MEDLINE | ID: mdl-28027742

ABSTRACT

PURPOSE: To determine which left atrial (LA) and left ventricular (LV) parameters are associated with future major adverse cardiac event (MACE) and whether these measurements have independent prognostic value beyond risk factors and computed tomography (CT)-derived coronary artery disease measures. MATERIALS AND METHODS: This retrospective analysis was performed under an IRB waiver and in HIPAA compliance. Subjects underwent coronary CT angiography (CCTA) using a dual-source CT system for acute chest pain evaluation. LV mass, LV ejection fraction (EF), LV end-systolic volume (ESV) and LV end-diastolic volume (EDV), LA ESV and LA diameter, septal wall thickness and cardiac chamber diameters were measured. MACE was defined as cardiac death, non-fatal myocardial infarction, unstable angina, or late revascularization. The association between cardiac CT measures and the occurrence of MACE was quantified using Cox proportional hazard analysis. RESULTS: 225 subjects (age, 56.2±11.2; 140 males) were analyzed, of whom 42 (18.7%) experienced a MACE during a median follow-up of 13 months. LA diameter (HR:1.07, 95%CI:1.01-1.13permm) and LV mass (HR:1.05, 95%CI:1.00-1.10perg) remained significant prognostic factor of MACE after controlling for Framingham risk score. LA diameter and LV mass were also found to have prognostic value independent of each other. The other morphologic and functional cardiac measures were no significant prognostic factors for MACE. CONCLUSION: CT-derived LA diameter and LV mass are associated with future MACE in patients undergoing evaluation for chest pain, and portend independent prognostic value beyond traditional risk factors, coronary calcium score, and obstructive coronary artery disease.


Subject(s)
Chest Pain/diagnostic imaging , Acute Pain/diagnostic imaging , Acute Pain/pathology , Angina, Unstable/diagnostic imaging , Angina, Unstable/pathology , Chest Pain/pathology , Computed Tomography Angiography , Coronary Angiography/methods , Coronary Artery Disease/complications , Female , Heart Atria/diagnostic imaging , Heart Atria/pathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/pathology , Humans , Male , Middle Aged , Myocardial Infarction/complications , Organ Size , Predictive Value of Tests , Prognosis , Retrospective Studies , Risk Factors , Tomography, X-Ray Computed/methods , Ventricular Function, Left/physiology
20.
Eur Radiol ; 27(6): 2292-2297, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27686566

ABSTRACT

OBJECTIVES: To investigate the relationship between image quality and patient size at 100 kilovoltage (kV) compared to 120 kV ECG-gated Triple-Rule-Out CT angiography (TRO-CTA). METHODS: We retrospectively included 73 patients (age 64 ± 14 years) who underwent retrospective ECG-gated chest CTA. 40 patients were scanned with 100 kV while 33 patients with 120 kV. Body mass index (BMI), patients' chest circumference (PC) and thoracic surface area (TSA) were recorded. Quantitative image quality was assessed as vascular attenuation in the ascending aorta (AA), pulmonary trunk (PA) and left coronary artery (LCA) and the signal-to-noise ratio (SNR) in the AA. RESULTS: There was no significant difference in BMI (26.0 ± 4.6 vs. 28.0 ± 6.7 kg/m2), PC (103 ± 7 vs. 104 ± 10 cm2) and TSA (92 ± 15 vs. 91 ± 19 cm2) between 100 kV and 120 kV group. Mean vascular attenuation was significantly higher in the 100 kV compared to the 120 kV group (AA 438 vs. 354 HU, PA 460 vs. 349 HU, LCA 370 vs. 299 HU all p < 0.001). SNR was not significantly different, even after adjusting for patient size. Radiation dose was significantly lower in the 100 kV group (10.7 ± 4.1 vs. 20.7 ± 10.7 mSv; p < 0.001). CONCLUSIONS: 100 kV TRO-CTA is feasible in normal-to-overweight patients while maintaining image quality and achieving substantial dose reduction. KEY POINTS: • 100 kV protocols result in a significantly lower radiation dose. • Mean vascular attenuation is significantly higher using 100 kV. • SNR and CNR are not significantly different between 100 kV and 120 kV. • 100 kV CTA is feasible regardless of patient size while maintaining image quality.


Subject(s)
Computed Tomography Angiography/standards , Overweight/diagnostic imaging , Aorta/diagnostic imaging , Body Mass Index , Body Size , Computed Tomography Angiography/methods , Coronary Vessels/diagnostic imaging , Electrocardiography , Feasibility Studies , Female , Humans , Male , Middle Aged , Pulmonary Artery , Radiation Dosage , Retrospective Studies , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...