1.
Ultrasound Med Biol ; 47(12): 3480-3490, 2021 12.
Article in English | MEDLINE | ID: mdl-34507874

ABSTRACT

A change in elastin and collagen content is indicative of damage caused by hypertension, which changes the non-linear behavior of the vessel wall. This study was aimed at investigating the feasibility of monitoring the non-linear material behavior in an angiotensin II hypertensive mice model. Aortas from 13 hypertensive mice were imaged with pulse wave imaging (PWI) over 4 wk using a 40-MHz linear array. The pulse wave velocity was estimated using two wave features: (i) the maximum axial acceleration of the foot (PWVdia) and (ii) the maximum axial acceleration of the dicrotic notch (PWVend-sys). The Bramwell-Hill equation was used to derive the compliance at diastolic and end-systolic pressure. This study determined the potential of PWI in a hypertensive mouse model to image and quantify the non-linear material behavior in vivo. End-systolic compliance could differentiate between the sham and angiotensin II groups, whereas diastolic compliance could not, indicating that PWI can detect early collagen-dominated remodeling.


Subject(s)
Aorta, Abdominal , Hypertension , Animals , Aorta, Abdominal/diagnostic imaging , Blood Pressure , Feasibility Studies , Mice , Pulse Wave Analysis
2.
Article in English | MEDLINE | ID: mdl-33950838

ABSTRACT

Pulse wave imaging (PWI) is an ultrasound imaging modality that estimates the wall stiffness of an imaged arterial segment by tracking the pulse wave propagation. The aim of the present study is to integrate PWI with vector flow imaging, enabling simultaneous and co-localized mapping of vessel wall mechanical properties and 2-D flow patterns. Two vector flow imaging techniques were implemented using the PWI acquisition sequence: 1) multiangle vector Doppler and 2) a cross-correlation-based vector flow imaging (CC VFI) method. The two vector flow imaging techniques were evaluated in vitro using a vessel phantom with an embedded plaque, along with spatially registered fluid structure interaction (FSI) simulations with the same geometry and inlet flow as the phantom setup. The flow magnitude and vector direction obtained through simulations and phantom experiments were compared in a prestenotic and stenotic segment of the phantom and at five different time frames. In most comparisons, CC VFI provided significantly lower bias or precision than the vector Doppler method ( ) indicating better performance. In addition, the proposed technique was applied to the carotid arteries of nonatherosclerotic subjects of different ages to investigate the relationship between PWI-derived compliance of the arterial wall and flow velocity in vivo. Spearman's rank-order test revealed positive correlation between compliance and peak flow velocity magnitude ( rs = 0.90 and ), while significantly lower compliance ( ) and lower peak flow velocity magnitude ( ) were determined in older (54-73 y.o.) compared with young (24-32 y.o.) subjects. Finally, initial feasibility was shown in an atherosclerotic common carotid artery in vivo. The proposed imaging modality successfully provided information on blood flow patterns and arterial wall stiffness and is expected to provide additional insight in studying carotid artery biomechanics, as well as aid in carotid artery disease diagnosis and monitoring.


Subject(s)
Carotid Arteries , Carotid Artery Diseases , Aged , Blood Flow Velocity , Carotid Arteries/diagnostic imaging , Diagnostic Imaging , Humans , Phantoms, Imaging , Pulse Wave Analysis , Ultrasonography
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6200-6203, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31947259

ABSTRACT

Methods used in clinical practice to diagnose and monitor atherosclerosis present limitations. Imaging the mechanical properties of the arterial wall has demonstrated the potential evaluate plaque vulnerability and assess the risk for stroke. Adaptive Pulse Wave Imaging (PWI) is a non-invasive ultrasound imaging technique, which automatically detects points of spatial mechanical inhomogeneity along the imaged artery and provides piecewise stiffness characterization. The aims of the present study are to: 1) demonstrate the initial feasibility of adaptive PWI to image the mechanical properties of an atherosclerotic plaque 2) demonstrate the feasibility to combine adaptive PWI with vector Doppler in a single imaging modality in order to simultaneously obtain information plaque mechanical properties and plaque hemodynamics. The common carotid arteries of 1 healthy subject and 2 carotid artery disease patients were scanned in vivo. One of the patients underwent carotid endarterectomy and a plaque sample was retrieved. In this patient, a higher compliance value of the stenotic segment was estimated by Adaptive PWI as compared with the adjacent arterial wall, and the healthy carotid artery. This was corroborated by histological staining of the plaque sample, which revealed the presence of a large necrotic core and a thrombus, characteristics associated with reduced stiffness. Moreover, the same sequence demonstrated the feasibility to obtain both stiffness maps and vector flow information, showing promise in atherosclerosis diagnosis and patient care.


Subject(s)
Atherosclerosis/diagnostic imaging , Carotid Artery Diseases/diagnostic imaging , Plaque, Atherosclerotic/diagnostic imaging , Ultrasonography, Doppler , Carotid Arteries/diagnostic imaging , Endarterectomy, Carotid , Humans
4.
Article in English | MEDLINE | ID: mdl-28792891

ABSTRACT

Pulse wave imaging (PWI) is a noninvasive technique for tracking the propagation of the pulse wave along the arterial wall. The 3-D ultrasound imaging would aid in objectively estimating the pulse wave velocity (PWV) vector. This paper aims to introduce a novel PWV estimation method along the propagation direction, validate it in phantoms, and test its feasibility in vivo. A silicone vessel phantom consisting of a stiff and a soft segment along the longitudinal axis and a silicone vessel with a plaque were constructed. A 2-D array with a center frequency of 2.5 MHz was used. Propagation was successfully visualized in 3-D in each phantom and in vivo in six healthy subjects. In three of the healthy subjects, results were compared against conventional PWI using a linear array. PWVs were estimated in the stiff (3.42 ± 0.23 m [Formula: see text]) and soft (2.41 ± 0.07 m [Formula: see text]) phantom segments. Good agreement was found with the corresponding static testing values (stiff: 3.41 m [Formula: see text] and soft: 2.48 m [Formula: see text]). PWI-derived vessel compliance values were validated with dynamic testing. Comprehensive views of pulse propagation in the plaque phantom were generated and compared against conventional PWI acquisitions. Good agreement was found in vivo between the results of 4-D PWI (4.80 ± 1.32 m [Formula: see text]) and conventional PWI (4.28±1.20 m [Formula: see text]) ( n=3 ). PWVs derived for all of the healthy subjects ( n = 6 ) were within the physiological range. Thus, the 4-D PWI was successfully validated in phantoms and used to image the pulse wave propagation in normal human subjects in vivo.


Subject(s)
Imaging, Three-Dimensional/methods , Pulse Wave Analysis/methods , Transducers , Adult , Carotid Artery, Common/diagnostic imaging , Feasibility Studies , Humans , Phantoms, Imaging , Young Adult
5.
Phys Med Biol ; 62(5): 1700-1730, 2017 03 07.
Article in English | MEDLINE | ID: mdl-28002039

ABSTRACT

Pulse wave velocity (PWV) is a surrogate marker of arterial stiffness linked to cardiovascular morbidity. Pulse wave imaging (PWI) is a technique developed by our group for imaging the pulse wave propagation in vivo. PWI requires high temporal and spatial resolution, which conventional ultrasonic imaging is unable to simultaneously provide. Coherent compounding is known to address this tradeoff and provides full aperture images at high frame rates. This study aims to implement PWI using coherent compounding within a GPU-accelerated framework. The results of the implemented method were validated using a silicone phantom against static mechanical testing. Reproducibility of the measured PWVs was assessed in the right common carotid of six healthy subjects (n = 6) approximately 10-15 mm before the bifurcation during two cardiac cycles over the course of 1-3 d. Good agreement of the measured PWVs (3.97 ± 1.21 m s-1, 4.08 ± 1.15 m s-1, p = 0.74) was obtained. The effects of frame rate, transmission angle and number of compounded plane waves on PWI performance were investigated in the six healthy volunteers. Performance metrics such as the reproducibility of the PWVs, the coefficient of determination (r 2), the SNR of the PWI axial wall velocities ([Formula: see text]) and the percentage of lateral positions where the pulse wave appears to arrive at the same time-point, indicating inadequacy of the temporal resolution (i.e. temporal resolution misses) were used to evaluate the effect of each parameter. Compounding plane waves transmitted at 1° increments with a linear array yielded optimal performance, generating significantly higher r 2 and [Formula: see text] values (p ⩽ 0.05). Higher frame rates (⩾1667 Hz) produced improvements with significant gains in the r 2 coefficient (p ⩽ 0.05) and significant increase in both r 2 and [Formula: see text] from single plane wave imaging to 3-plane wave compounding (p ⩽ 0.05). Optimal performance was established at 2778 Hz with 3 plane waves and at 1667 Hz with 5 plane waves.


Subject(s)
Carotid Arteries/diagnostic imaging , Phantoms, Imaging , Pulse Wave Analysis/methods , Ultrasonography/methods , Adult , Heart Rate , Humans , Reproducibility of Results , Young Adult
6.
IEEE Trans Med Imaging ; 35(1): 13-28, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26168432

ABSTRACT

Atherosclerosis and Abdominal Aortic Aneurysms (AAAs) are two common vascular diseases associated with mechanical changes in the arterial wall. Pulse Wave Imaging (PWI), a technique developed by our group to assess and quantify the mechanical properties of the aortic wall in vivo, may provide valuable diagnostic information. This work implements piecewise PWI (pPWI), an enhanced version of PWI designed for focal vascular diseases. Localized, sub-regional PWVs and PWI moduli ( EPWI ) were estimated within 2-4 mm wall segments of murine normal, atherosclerotic and aneurysmal arteries. Overall, stiffness was found to increase in the atherosclerotic cases. The mean sub-regional PWV was found to be 2.57±0.18 m/s for the normal aortas (n = 7) with a corresponding mean EPWI of 43.82±5.86 kPa. A significant increase ( (p ≤ 0.001)) in the group means of the sub-regional PWVs was found between the normal aortas and the aortas of mice on high-fat diet for 20 ( 3.30±0.36 m/s) and 30 weeks ( 3.56±0.29 m/s). The mean of the sub-regional PWVs ( 1.57±0.78 m/s) and EPWI values ( 19.23±15.47 kPa) decreased significantly in the aneurysmal aortas (p ≤ 0.05) . Furthermore, the mean coefficient of determination (r(2)) of the normal aortas was significantly higher (p ≤ 0.05) than those of the aneurysmal and atherosclerotic cases. These findings demonstrated that pPWI may be able to provide useful biomarkers for monitoring focal vascular diseases.


Subject(s)
Aorta/diagnostic imaging , Carotid Arteries/diagnostic imaging , Pulse Wave Analysis/methods , Animals , Aorta/pathology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/pathology , Atherosclerosis/diagnostic imaging , Atherosclerosis/pathology , Carotid Arteries/pathology , Carotid Artery Diseases/diagnostic imaging , Carotid Artery Diseases/pathology , Disease Models, Animal , Disease Progression , Male , Mice , Mice, Knockout , Ultrasonography
7.
Article in English | MEDLINE | ID: mdl-26168177

ABSTRACT

Harmonic motion imaging for focused ultrasound (HMIFU) is a recently developed high-intensity focused ultrasound (HIFU) treatment monitoring method that utilizes an amplitude-modulated therapeutic ultrasound beam to induce an oscillatory radiation force at the HIFU focus and estimates the focal tissue displacement to monitor the HIFU thermal treatment. In this study, the performance of HMIFU under acoustic, thermal, and mechanical effects was investigated. The performance of HMIFU was assessed in ex vivo canine liver specimens (n = 13) under slow denaturation or boiling regimes. A passive cavitation detector (PCD) was used to assess the acoustic cavitation activity, and a bare-wire thermocouple was used to monitor the focal temperature change. During lesioning with slow denaturation, high quality displacements (correlation coefficient above 0.97) were observed under minimum cavitation noise, indicating the tissue initial-softening-then- stiffening property change. During HIFU with boiling, HMIFU monitored a consistent change in lesion-to-background displacement contrast (0.46 ± 0.37) despite the presence of strong cavitation noise due to boiling during lesion formation. Therefore, HMIFU effectively monitored softening-then-stiffening during lesioning under slow denaturation, and detected lesioning under boiling with a distinct change in displacement contrast under boiling in the presence of cavitation. In conclusion, HMIFU was shown under both boiling and slow denaturation regimes to be effective in HIFU monitoring and lesioning identification without being significantly affected by cavitation noise.


Subject(s)
High-Intensity Focused Ultrasound Ablation/methods , Surgery, Computer-Assisted/methods , Acoustics , Animals , Dogs , Liver/physiology , Liver/surgery , Temperature