Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
J Clin Med ; 12(14)2023 Jul 10.
Article in English | MEDLINE | ID: mdl-37510711

ABSTRACT

Ex vivo shoulder motion simulators are commonly used to study shoulder biomechanics but are often limited to performing simple planar motions at quasi-static speeds using control architectures that do not allow muscles to be deactivated. The purpose of this study was to develop an open-loop tendon excursion controller with iterative learning and independent muscle control to simulate complex multiplanar motion at functional speeds and allow for muscle deactivation. The simulator performed abduction/adduction, faceted circumduction, and abduction/adduction (subscapularis deactivation) using a cadaveric shoulder with an implanted reverse total shoulder prosthesis. Kinematic tracking accuracy and repeatability were assessed using maximum absolute error (MAE), root mean square error (RMSE), and average standard deviation (ASD). During abduction/adduction and faceted circumduction, the RMSE did not exceed 0.3, 0.7, and 0.8 degrees for elevation, plane of elevation, and axial rotation, respectively. During abduction/adduction, the ASD did not exceed 0.2 degrees. Abduction/adduction (subscapularis deactivation) resulted in a loss of internal rotation, which could not be restored at low elevation angles. This study presents a novel control architecture, which can accurately simulate complex glenohumeral motion. This simulator will be used as a testing platform to examine the effect of shoulder pathology, treatment, and rehabilitation on joint biomechanics during functional shoulder movements.

2.
JOR Spine ; 6(2): e1250, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37361335

ABSTRACT

Objective: Whilst microdiscectomy is an excellent reliever of pain for recalcitrant lumbar disc herniation (LDH), it has a high failure rate over time due to the ensuing reduction in mechanical stabilization and support of the spine. One option is to clear the disc and replace it with a nonhygroscopic elastomer. Here, we present the evaluation of biomechanical and biological behavior of a novel elastomeric nucleus device (Kunovus disc device [KDD]), consisting of a silicone jacket and a two-part in situ curing silicone polymer filler. Materials and Methods: ISO 10993 and American Society for Testing and Materials (ASTM) standards were used to evaluate the biocompatibility and mechanics of KDD. Sensitization, intracutaneous reactivity, acute systemic toxicity, genotoxicity, muscle implantation study, direct contact matrix toxicity assay, and cell growth inhibition assay were performed. Fatigue test, static compression creep testing, expulsion testing, swell testing, shock testing, and aged fatigue testing were conducted to characterize the mechanical and wear behavior of the device. Cadaveric studies to develop a surgical manual and evaluate feasibility were conducted. Finally, a first-in-human implantation was conducted to complete the proof of principle. Results: The KDD demonstrated exceptional biocompatibility and biodurability. Mechanical tests showed no Barium-containing particles in fatigue test, no fracture of nucleus in static compression creep testing, no extrusion and swelling, and no material failure in shock and aged fatigue testing. Cadaver training sessions showed that KDD was deemed implantable during microdiscectomy procedures in a minimally invasive manner. Following IRB approval, the first implantation in a human showed no intraoperative vascular and neurological complications and demonstrated feasibility. This successfully completed Phase 1 development of the device. Conclusion: The elastomeric nucleus device may mimic native disc behavior in mechanical tests, offering an effective way for treating LDH by way of Phase 2 and subsequent clinical trials or postmarket surveillance in the future.

3.
Biomed Eng Online ; 22(1): 31, 2023 Mar 27.
Article in English | MEDLINE | ID: mdl-36973768

ABSTRACT

BACKGROUND: Isolated ACL reconstructions (ACLR) demonstrate limitations in restoring native knee kinematics. This study investigates the knee mechanics of ACLR plus various anterolateral augmentations using a patient-specific musculoskeletal knee model. MATERIALS AND METHODS: A patient-specific knee model was developed in OpenSim using contact surfaces and ligament details derived from MRI and CT data. The contact geometry and ligament parameters were varied until the predicted knee angles for intact and ACL-sectioned models were validated against cadaveric test data for that same specimen. Musculoskeletal models of the ACLR combined with various anterolateral augmentations were then simulated. Knee angles were compared between these reconstruction models to determine which technique best matched the intact kinematics. Also, ligament strains calculated by the validated knee model were compared to those of the OpenSim model driven by experimental data. The accuracy of the results was assessed by calculating the normalised RMS error (NRMSE); an NRMSE < 30% was considered acceptable. RESULTS: All rotations and translations predicted by the knee model were acceptable when compared to the cadaveric data (NRMSE < 30%), except for the anterior/posterior translation (NRMSE > 60%). Similar errors were observed between ACL strain results (NRMSE > 60%). Other ligament comparisons were acceptable. All ACLR plus anterolateral augmentation models restored kinematics toward the intact state, with ACLR plus anterolateral ligament reconstruction (ACLR + ALLR) achieving the best match and the greatest strain reduction in ACL, PCL, MCL, and DMCL. CONCLUSION: The intact and ACL-sectioned models were validated against cadaveric experimental results for all rotations. It is acknowledged that the validation criteria are very lenient; further refinement is required for improved validation. The results indicate that anterolateral augmentation moves the kinematics closer to the intact knee state; combined ACLR and ALLR provide the best outcome for this specimen.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Joint Instability , Humans , Biomechanical Phenomena , Anterior Cruciate Ligament Injuries/surgery , Range of Motion, Articular , Anterior Cruciate Ligament Reconstruction/methods , Joint Instability/surgery , Cadaver , Anterior Cruciate Ligament/diagnostic imaging , Anterior Cruciate Ligament/surgery , Knee Joint/diagnostic imaging , Knee Joint/surgery
4.
Int J Spine Surg ; 16(5): 802-814, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36007955

ABSTRACT

BACKGROUND: The practice of cement augmentation in pedicle screw fixation is well established. However, there is a lack of consensus regarding the optimal screw design or cement type. This remains a clinically important question given the incidence of cement augmentation-associated complications. While fenestrated screws have become widely used in clinical practice, the relationship between fenestration placement along the screw axis and cement plume geometry and pullout strength have yet to be clarified. This study was designed to evaluate the mechanical and geometric properties of different fenestrated screw designs and cement viscosities in pedicle screw fixation. METHODS: Three different screw fenestration configurations and 2 different cement viscosities were examined in this study. Axial pullout tests were conducted in both foam blocks and cadaveric vertebrae. All vertebral specimens underwent tests of bone mineral density. In the foam blocks, 6 tests were conducted for each augmentation combination and also for nonaugmented controls. In the cadaveric testing, 36 lumbar vertebrae were instrumented with a cemented and uncemented control screw to compare features of fixation. Computed tomography (CT) images were taken to assess the geometric profile of the cement plumes in both the foam blocks and the cadaveric vertebrae. RESULTS: In both foam blocks and vertebral specimens, cementation was shown to confer a significant increase in pullout strength. Significant correlations existed between the anterior-posterior and lateral cement plume diameters and pullout strength in cadaveric vertebra and foam blocks, respectively. Within instrumented vertebra, variables such as the width of the vertebral body and screw insertion were found to significantly correlate with enhanced fixation. CT analysis of the instrumented vertebra demonstrated that a centrally distributed pattern of fenestrations was found to result in a cement plume with consistently predictable distribution within the vertebral body, without evidence of leak. CONCLUSION: Cementation of fenestrated pedicle screws increases overall pullout forces; however, there is an unclear relationship between the geometric properties of the cement plume and the overall strength of the screw-bone interface. This study demonstrates that the plume diameter, vertebral body width, and angle of screw insertion are correlated with enhanced pullout strength. Furthermore, varying the fenestration design of injectable screws resulted in a set of predictable plume patterns, which may be associated with fewer complications. Further investigation is required to clarify the optimal geometric and biomechanical properties of injectable pedicle screws and their role in establishing the cement-bone interface. CLINICAL RELEVANCE: This study is relevant to currently practicing spinal surgeons and biomechanical engineers.

5.
PLoS One ; 17(1): e0262684, 2022.
Article in English | MEDLINE | ID: mdl-35085320

ABSTRACT

BACKGROUND: The ligaments in the knee are prone to injury especially during dynamic activities. The resulting instability can have a profound impact on a patient's daily activities and functional capacity. Musculoskeletal knee modelling provides a non-invasive tool for investigating ligament force-strain behaviour in various dynamic scenarios, as well as potentially complementing existing pre-planning tools to optimise surgical reconstructions. However, despite the development and validation of many musculoskeletal knee models, the effect of modelling parameters on ligament mechanics has not yet been systematically reviewed. OBJECTIVES: This systematic review aimed to investigate the results of the most recent studies using musculoskeletal modelling techniques to create models of the native knee joint, focusing on ligament mechanics and modelling parameters in various simulated movements. DATA SOURCES: PubMed, ScienceDirect, Google Scholar, and IEEE Xplore. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Databases were searched for articles containing any numerical ligament strain or force data on the intact, ACL-deficient, PCL-deficient, or lateral extra-articular reconstructed (LER) knee joints. The studies had to derive these results from musculoskeletal modelling methods. The dates of the publications were between 1 January 1995 and 30 November 2021. METHOD: A customised data extraction form was created to extract each selected study's critical musculoskeletal model development parameters. Specific parameters of the musculoskeletal knee model development used in each eligible study were independently extracted, including the (1) musculoskeletal model definition (i.e., software used for modelling, knee type, source of geometry, the inclusion of cartilage and menisci, and articulating joints and joint boundary conditions (i.e., number of degrees of freedom (DoF), subjects, type of activity, collected data and type of simulation)), (2) specifically ligaments modelling techniques (i.e., ligament bundles, attachment points, pathway, wrapping surfaces and ligament material properties such as stiffness and reference length), (3) sensitivity analysis, (4) validation approaches, (5) predicted ligament mechanics (i.e., force, length or strain) and (6) clinical applications if available. The eligible papers were then discussed quantitatively and qualitatively with respect to the above parameters. RESULTS AND DISCUSSION: From the 1004 articles retrieved by the initial electronic search, only 25 met all inclusion criteria. The results obtained by aggregating data reported in the eligible studies indicate that considerable variability in the predicted ligament mechanics is caused by differences in geometry, boundary conditions and ligament modelling parameters. CONCLUSION: This systematic review revealed that there is currently a lack of consensus on knee ligament mechanics. Despite this lack of consensus, some papers highlight the potential of developing translational tools using musculoskeletal modelling. Greater consistency in model design, incorporation of sensitivity assessment of the model outcomes and more rigorous validation methods should lead to better agreement in predictions for ligament mechanics between studies. The resulting confidence in the musculoskeletal model outputs may lead to the development of clinical tools that could be used for patient-specific treatments.


Subject(s)
Anterior Cruciate Ligament/physiology , Knee Joint/physiology , Anterior Cruciate Ligament Injuries/physiopathology , Biomechanical Phenomena/physiology , Computer Simulation , Humans , Mechanical Phenomena
6.
Am J Sports Med ; 49(13): 3628-3637, 2021 11.
Article in English | MEDLINE | ID: mdl-34495796

ABSTRACT

BACKGROUND: Preoperative quantification of bone loss has a significant effect on surgical decision making and patient outcomes. Various measurement techniques for calculating glenoid bone loss have been proposed in the literature. To date, no studies have directly compared measurement techniques to determine which technique, if any, is the most reliable. PURPOSE/HYPOTHESIS: To identify the most consistent and accurate techniques for measuring glenoid bone loss in anterior glenohumeral instability. Our hypothesis was that linear measurement techniques would have lower consistency and accuracy than surface area and statistical shape model-based measurement techniques. STUDY DESIGN: Controlled laboratory study. METHODS: In 6 fresh-frozen human shoulders, 3 incremental bone defects were sequentially created resulting in a total of 18 glenoid bone defect samples. Analysis was conducted using 2D and 3D computed tomography (CT) en face images. A total of 6 observers (3 experienced and 3 with less experience) measured the bone defect of all samples with Horos imaging software using 5 common methods. The methods included 2 linear techniques (Shaha, Griffith), 2 surface techniques (Barchilon, PICO), and 1 statistical shape model formula (Giles). Intraclass correlation (ICC) using a consistency model was used to determine consistency between observers for each of the measurement methods. Paired t tests were used to calculate the accuracy of each measurement technique relative to physical measurement. RESULTS: For the more experienced observers, all methods indicated good consistency (ICC > 0.75; range, 0.75-0.88), except the Shaha method, which indicated moderate consistency (0.65 < ICC < 0.75; range, 0.65-0.74). Estimated consistency among the experienced observers was better for 2D than 3D images, although the differences were not significant (intervals contained 0). For less experienced observers, the Giles method in 2D had the highest estimated consistency (ICC, 0.88; 95% CI, 0.76-0.95), although Giles, Barchilon, Griffith, and PICO methods were not statistically different. Among less experienced observers, the 2D images using Barchilon and Giles methods had significantly higher consistency than the 3D images. Regarding accuracy, most of the methods statistically overestimated the actual physical measurements by a small amount (mean within 5%). The smallest bias was observed for the 2D Barchilon measurements, and the largest differences were observed for Giles and Griffith methods for both observer types. CONCLUSION: Glenoid bone loss calculation presents variability depending on the measurement technique, with different consistencies and accuracies. We recommend use of the Barchilon method by surgeons who frequently measure glenoid bone loss, because this method presents the best combined consistency and accuracy. However, for surgeons who measure glenoid bone loss occasionally, the most consistent method is the Giles method, although an adjustment for the overestimation bias may be required. CLINICAL RELEVANCE: The Barchilon method for measuring bone loss has the best combined consistency and accuracy for surgeons who frequently measure bone loss.


Subject(s)
Joint Instability , Shoulder Joint , Cadaver , Humans , Joint Instability/diagnostic imaging , Reproducibility of Results , Shoulder Joint/diagnostic imaging , Tomography, X-Ray Computed
7.
Orthop J Sports Med ; 9(4): 23259671211000464, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33997064

ABSTRACT

BACKGROUND: Meniscus root repairs are important for restoring knee function after a complete meniscus root tear. Various suturing patterns have been proposed for the root repair. The 2-simple-stitches (TSS) method is currently the preferred technique, as it is simplest to perform and allows the least displacement of the meniscus root. PURPOSE: To compare the biomechanical properties of a posterior medial meniscus transtibial root repair consisting of an all-inside meniscal repair device (AMRD) construct with the TSS pullout suture pattern. STUDY DESIGN: Controlled laboratory study. METHODS: Ten pairs of cadaveric medial menisci were prepared with 1 of the 2 constructs. The constructs were randomized between pairs. All constructs were subjected to preloading with 2 N for 10 seconds and then cyclic loading from 5 N to 20 N for 1000 cycles at a frequency of 0.5 Hz. Subsequently, the menisci were loaded to failure at a rate of 0.5 mm/s. All loads were applied in-line with the circumferential meniscal fibers near the posterior medial meniscal horn. RESULTS: The mean yield load and stiffness were similar for both constructs. The elongation after cyclic loading was greater for the AMRD. The displacement at both yield load and ultimate failure were also higher for the AMRD. The ultimate failure load of the AMRD was also significantly higher. During load to failure, the mode of failure in the AMRD was heterogeneous. All the TSS constructs failed by suture cutout. CONCLUSION: Posterior medial meniscus root repairs using both the AMRD and TSS constructs have elongation under the biomechanically acceptable threshold of 3 mm. The stiffness and yield loads indicate similar mechanical properties of the constructs. However, the significantly higher elongation for the AMRD leaves the TSS method as the preferred option for transtibial repairs. Despite this, the AMRD construct may still represent a viable alternative to the TSS suture pattern, comparable to alternative suture patterns with similar limitations. CLINICAL RELEVANCE: The AMRD construct may represent a viable alternative to the TSS suture pattern.

8.
J ISAKOS ; 6(2): 66-73, 2021 03.
Article in English | MEDLINE | ID: mdl-33832979

ABSTRACT

OBJECTIVES: Given the common occurrence of residual laxity and re-injury post anterior cruciate ligament reconstruction (ACLR), additional anterolateral procedures are increasingly used in combination with an ACLR. Despite the perception that there is a risk of over-constraining the lateral tibiofemoral (LTF) compartment, potentially leading to osteoarthritis, assessment on their effect on intra-articular compartment pressures is still lacking. Our objective was therefore, through a pilot biomechanical study, to compare LTF contact pressures after the most commonly used anterolateral procedures. METHODS: A controlled laboratory pilot study was performed using 4 fresh-frozen cadaveric whole lower limbs. Through 0° to 90° of flexion, LTF contact pressures were measured with a Tekscan sensor, located under the lateral meniscus. Knee kinematics were obtained in 3 conditions of rotation (NR: neutral, ER: external and IR: internal rotation) to record the position of the knees for each loading condition. A Motion Analysis system with a coordinate system based on CT scans 3D bone modelling was used. After an ACLR, defined as the reference baseline, 5 anterolateral procedures were compared: anterolateral ligament reconstruction (ALLR), modified Ellison, deep Lemaire, superficial Lemaire and modified MacIntosh procedures. The last 3 procedures were randomised. For each procedure, the graft was fixed in NR at 30° of flexion and with a tension of 20 N. RESULTS: Compared with isolated ACLR, addition of either ALLR or modified Ellison procedure did not increased the overall LTF contact pressure (all p>0.05) through the full range of flexion for the IR condition. Conversely, deep Lemaire, superficial Lemaire and modified MacIntosh procedure (all p<0.05) did increase the overall LTF contact pressure compared with ACLR in IR. No significant difference was observed in ER and NR conditions. CONCLUSION: This pilot study, comparing the main anterolateral procedures, revealed that addition of either ALLR or modified Ellison procedure did not change the overall contact pressure in the LTF compartment through 0° to 90° of knee flexion. In contrast, the deep and superficial Lemaire, and modified MacIntosh procedures significantly increased overall LTF contact pressures when the knee was internally rotated.


Subject(s)
Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/methods , Ligaments, Articular/surgery , Tenodesis/methods , Anterior Cruciate Ligament Injuries/physiopathology , Biomechanical Phenomena , Cadaver , Humans , Joint Instability/surgery , Knee Joint/physiopathology , Knee Joint/surgery , Ligaments, Articular/physiopathology , Pilot Projects , Pressure , Range of Motion, Articular , Rotation
9.
J ISAKOS ; 6(2): 74-81, 2021 03.
Article in English | MEDLINE | ID: mdl-33832980

ABSTRACT

OBJECTIVE: The optimal anterolateral procedure to control anterolateral rotational laxity of the knee is still unknown. The objective was to compare the ability of five anterolateral procedures performed in combination with anterior cruciate ligament reconstruction (ACLR) to restore native knee kinematics in the setting of a deficient anterior cruciate ligament (ACL) and anterolateral structures. METHODS: A controlled laboratory study was performed using 10 fresh-frozen cadaveric whole lower limbs with intact iliotibial band. Kinematics from 0° to 90° of flexion were recorded using a motion analysis three-dimensional (3D) optoelectronic system, allowing assessment of internal rotation (IR) and anteroposterior (AP) tibial translation at 30° and 90° of flexion. Joint centres and bony landmarks were calculated from 3D bone models obtained from CT scans. Intact knee kinematics were assessed initially, followed by sequential section of the ACL and anterolateral structures (anterolateral ligament, anterolateral capsule and Kaplan fibres). After ACLR, five anterolateral procedures were performed consecutively on the same knee: ALLR, modified Ellison, deep Lemaire, superficial Lemaire and modified MacIntosh. The last three procedures were randomised. For each procedure, the graft was fixed in neutral rotation at 30° of flexion and with a tension of 20 N. RESULTS: Isolated ACLR did not restore normal overall knee kinematics in a combined ACL plus anterolateral-deficient knee, leaving a residual tibial rotational laxity (p=0.034). Only the ALLR (p=0.661) and modified Ellison procedure (p=0.641) restored overall IR kinematics to the normal intact state. Superficial and deep Lemaire and modified MacIntosh tenodeses overconstrained IR, leading to shifted and different kinematics compared with the intact condition (p=0.004, p=0.001 and p=0.045, respectively). Compared with ACLR state, addition of an anterolateral procedure did not induce any additional control on AP translation at 30° and 90° of flexion (all p>0.05), except for the superficial Lemaire procedure at 90° (p=0.032). CONCLUSION: In biomechanical in vitro setting, a comparison of five anterolateral procedures revealed that addition of either ALLR or modified Ellison procedure restored overall native knee kinematics in a combined ACL plus anterolateral-deficient knee. Superficial and deep Lemaire and modified MacIntosh tenodeses achieved excellent rotational control but overconstrained IR, leading to a change from intact knee kinematics. LEVEL OF EVIDENCE: The level-of-evidence statement does not apply for this laboratory experiments study.


Subject(s)
Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/methods , Joint Instability/surgery , Knee Joint/surgery , Tenodesis/methods , Biomechanical Phenomena , Cadaver , Fascia Lata/surgery , Humans , Knee Joint/physiopathology , Ligaments, Articular/physiopathology , Ligaments, Articular/surgery , Range of Motion, Articular , Plastic Surgery Procedures/methods , Rotation , Tibia/physiopathology , Tibia/surgery
10.
Orthop J Sports Med ; 9(1): 2325967120969640, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33490294

ABSTRACT

BACKGROUND: Suture pullout during rehabilitation may result in loss of tension in the inferior glenohumeral ligament (IGHL) and contribute to recurrent instability after capsular plication, performed with or without labral repair. To date, the suture pullout strength in the IGHL is not well-documented. This may contribute to recurrent instability. PURPOSE/HYPOTHESIS: A cadaveric biomechanical study was designed to investigate the suture pullout strength of sutures in the IGHL. We hypothesized that there would be no significant variability of suture pullout strength between specimens and zones. Additionally, we sought to determine the impact of early mobilization on sutures in the IGHL at time zero. We hypothesized that capsular plication sutures would fail under low load. STUDY DESIGN: Descriptive laboratory study. METHODS: Seven fresh-frozen cadaveric shoulders were dissected to isolate the IGHL complex, which was then divided into 18 zones. Sutures in these zones were attached to a linear actuator, and the resistance to suture pullout was recorded. A suture pullout strength map of the IGHL was constructed. These loads were used to calculate the load applied at the hand that would initiate suture pullout in the IGHL. RESULTS: Mean suture pullout strength for all specimens was 61.6 ± 26.1 N. The maximum load found to cause suture pullout through tissue was found to be low, regardless of zone of the IGHL. Calculations suggest that an external rotation force applied to the hand of only 9.6 N may be sufficient to tear capsular sutures at time zero. CONCLUSION: This study did not provide clear evidence of desirable locations for fixation in the IGHL. However, given the low magnitude of failure loads, the results suggest the timetable for initiation of range-of-motion exercises should be reconsidered to prevent suture pullout through the IGHL. CLINICAL RELEVANCE: From this biomechanical study, the magnitude of force required to cause suture pullout through the IGHL is met or surpassed by normal postoperative early range-of-motion protocols.

11.
Animals (Basel) ; 10(11)2020 Nov 11.
Article in English | MEDLINE | ID: mdl-33187204

ABSTRACT

The current project aims to build on knowledge of the nociceptive capability of equine skin to detect superficial acute pain, particularly in comparison to human skin. Post-mortem samples of gluteal skin were taken from men (n = 5) and women (n = 5), thoroughbreds and thoroughbred types (mares, n = 11; geldings, n = 9). Only sections that contained epidermis and dermis through to the hypodermis were analysed. Epidermal depth, dermal depth and epidermal nerve counts were conducted by a veterinary pathologist. The results revealed no significant difference between the epidermal nerve counts of humans and horses (t = 0.051, p = 0.960). There were no significant differences between epidermal thickness of humans (26.8 µm) and horses (31.6 µm) for reference (left side) samples (t = 0.117, p = 0.908). The human dermis was significantly thinner than the horse dermis (t = -2.946, p = 0.007). Epidermal samples were thicker on the right than on the left, but only significantly so for horses (t = 2.291, p = 0.023), not for humans (t = 0.694, p = 0.489). The thicker collagenous dermis of horse skin may afford some resilience versus external mechanical trauma, though as this is below the pain-detecting nerve endings, it is not considered protective from external cutaneous pain. The superficial pain-sensitive epidermal layer of horse skin is as richly innervated and is of equivalent thickness as human skin, demonstrating that humans and horses have the equivalent basic anatomic structures to detect cutaneous pain. This finding challenges assumptions about the physical capacity of horses to feel pain particularly in comparison to humans, and presents physical evidence to inform the discussion and debate regarding the ethics of whipping horses.

12.
J Spine Surg ; 6(1): 3-12, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32309640

ABSTRACT

BACKGROUND: To assess whether lumbar pedicle screw placement with a minimally invasive surgical (MIS) vs. open technique imparts different biomechanical parameters and thus may affect failure rates. METHODS: Human cadaveric disarticulated lumbar vertebrae 1-5 were stabilised in cement. Pedicle screws were inserted either via the 'MIS' or 'open' technique, based on previously described anatomical landmarks. Each vertebra had one 'MIS' and one 'open' technique screw. Specimens were tested with an Instron mechanical testing machine, positioned to allow for testing of direct coaxial force. Load was applied until failure occurred, and load-displacement curves generated for each screw. RESULTS: Average failure load was found to be 685±399 N for MIS, versus 661±323 N for open technique (P=0.75). The average ultimate failure load was 748±421 N for MIS, versus 772±326 N for open (P=0.74). Average displacement until failure was 0.95±0.49 mm for MIS as compared to 0.95±0.62 mm for open (P=0.996). Axial stiffness was 936±217 N/mm for MIS and 1,016±263 N/mm for open (P=0.19). Average work required to result in failure was 0.84±1.09 J for MIS and 0.82±1.05 J for open (P=0.94). CONCLUSIONS: There was no significant difference in the biomechanical properties of the MIS as compared with open lumbar pedicle screws, when tested until failure under direct coaxial force. The clinical implication may be that there is no significant advantage in the biomechanical properties of MIS versus open lumbar pedicle screw insertion techniques.

13.
Knee ; 27(3): 871-877, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32220536

ABSTRACT

BACKGROUND: Patellar tendinopathy is an overuse condition affecting athletes, often with a high morbidity if left untreated. High-level evidence fails to support the use of surgery. A tibial tubercle osteotomy (TTO) has been suggested as a surgical option to improve patient outcomes. Our aim was to explore whether a distalising TTO will alter the patellar tendon to quadriceps tendon force ratio and the sagittal patellar tilt. METHODS: Six cadaver limbs were placed in a custom jig with a mechanical testing machine applying cyclical loads of 200-500 N to the quadriceps tendon. The knee was fixed at 0, 15, 30, 45, 60, 75 and 90° of flexion and a buckle transducer recorded the resultant patellar tendon force. Testing was performed with the native tibial tubercle position and with the tubercle distalised by 11 mm. Testing was also performed with the tubercle anteriorised by 10 mm at both of these tubercle positions, a total of four different testing positions. RESULTS: There was a significant decrease in the patellar tendon to quadriceps tendon force ratio from 30-60° of knee flexion. There was a significant increase in the sagittal patellar tilt at 30° of knee flexion with distalisation. CONCLUSION: This biomechanical study shows that the patellar tendon to quadriceps tendon force ratio can be altered with a distalising tibial tubercle osteotomy. A tibial tubercle osteotomy may be a biomechanical treatment option for recalcitrant patellar tendinopathy by decreasing the load through the patellar tendon, allowing the athlete to maintain higher training volumes and loads.


Subject(s)
Osteotomy , Patellar Ligament/surgery , Tendinopathy/surgery , Tibia/surgery , Aged , Aged, 80 and over , Biomechanical Phenomena/physiology , Cadaver , Female , Humans , Male , Middle Aged , Patellar Ligament/physiopathology , Tendinopathy/physiopathology , Weight-Bearing/physiology
14.
J Biomech Eng ; 141(10)2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31175841

ABSTRACT

As the use of glenoid suture anchors in arthroscopic and open reconstruction, for instability after Bankart lesions of the shoulder, increases, an emerging problem has been the incidence of glenoid rim fractures through suture drill holes. Very little is known regarding the effect of the Hill-Sachs lesion on the glenoid's susceptibility to fracture and how drill hole location can further affect this. This study used finite element modeling techniques to investigate the risk of fracture of the glenoid rim in relation to variable sized Hill-Sachs defects impacting on the anterior glenoid edge with suture anchor holes placed in varying positions. The distribution of Von Mises (VM) stresses and the factor of safety (FOS) for each of the configurations were calculated. The greatest peak in VM stresses was generated when the glenoid was loaded with a small Hill-Sachs lesion. The VM stresses were lessened and the FOS increased (reducing likelihood of failure) with increasing size of the Hill-Sachs lesion. Placement of the suture drill holes at 2 mm from the glenoid rim showed the highest risk of failure; and when combined with a medium sized Hill-Sachs lesion, which matched the central line of the drill holes, a potentially clinically significant configuration was presented. The results of this study are useful in assisting the surgeon in understanding the interaction between the Hill-Sachs lesion size and the placement of suture anchors with the purpose of minimizing the risk of subsequent rim fracture with new injury.

15.
J Orthop Traumatol ; 19(1): 11, 2018 Aug 21.
Article in English | MEDLINE | ID: mdl-30128979

ABSTRACT

BACKGROUND: In anterior cruciate ligament reconstruction, quadrupled semitendinosus (Quad ST) grafts have potential advantages over doubled semitendinosus-gracilis (ST/G) including larger diameter and gracilis preservation, however the ideal tibial fixation method of the resultant shorter Quad ST graft remains elusive if a fixed-loop suspensory fixation device is used on the femur. We investigated whether the tibial fixation biomechanical properties of a Quad ST fixed indirectly with polyethylene terephthalate tape tied over a screw in a full outside-in created tunnel was superior to a ST/G graft fixed with an interference screw. MATERIALS AND METHODS: In a controlled laboratory study, six cadaveric matched pairs of each construct were subjected to cyclic loading to mimic physiologic loading during rehabilitation. This included preconditioning cycling, cyclic loading to 220 N for 500 cycles, then cyclic loading to 500 N for 500 cycles. RESULTS: High standard deviations across the measured parameters occurred with no significant difference between measured parameters of elongation for the different constructs. Elongation of the Quad-ST construct was greater at 10 and 100 cycles, but not statistically different. Four of the six Quad-ST constructs failed below 100 cycles, compared with two failures below 100 cycles in the ST/G construct. There was a strong correlation between cycles to failure and bone mineral density for the Quad ST-tape constructs. CONCLUSIONS: Tibial fixation of Quad ST with a tied tape-screw construct in a full-length tunnel was not biomechanically superior to ST/G graft fixed with an interference screw, exhibited greater nonsignificant construct elongation with earlier failure, and was more reliant on bone mineral density. LEVEL OF EVIDENCE: In vitro laboratory study.


Subject(s)
Anterior Cruciate Ligament Reconstruction/methods , Anterior Cruciate Ligament/surgery , Bone Screws , Gracilis Muscle/transplantation , Tendons/transplantation , Tibia/surgery , Biomechanical Phenomena , Cadaver , Humans , Middle Aged
16.
PeerJ ; 6: e5120, 2018.
Article in English | MEDLINE | ID: mdl-30042881

ABSTRACT

The aim of this study was to determine the role of the perlecan (Hspg2) heparan sulphate (HS) side chains on cell and matrix homeostasis in tail and Achilles tendons in 3 and 12 week old Hspg2 exon 3 null HS deficient (Hspg2Δ3 - ∕Δ3 -) and C57 BL/6 Wild Type (WT) mice. Perlecan has important cell regulatory and matrix organizational properties through HS mediated interactions with a range of growth factors and morphogens and with structural extracellular matrix glycoproteins which define tissue function and allow the resident cells to regulate tissue homeostasis. It was expected that ablation of the HS chains on perlecan would severely disrupt normal tendon organization and functional properties and it was envisaged that this study would better define the role of HS in normal tendon function and in tendon repair processes. Tail and Achilles tendons from each genotype were biomechanically tested (ultimate tensile stress (UTS), tensile modulus (TM)) and glycosaminoglycan (GAG) and collagen (hydroxyproline) compositional analyses were undertaken. Tenocytes were isolated from tail tendons from each mouse genotype and grown in monolayer culture. These cultures were undertaken in the presence of FGF-2 to assess the cell signaling properties of each genotype. Total RNA was isolated from 3-12 week old tail and Achilles tendons and qRT-PCR was undertaken to assess the expression of the following genes Vcan, Bgn, Dcn, Lum, Hspg2, Ltbp1, Ltbp2, Eln and Fbn1. Type VI collagen and perlecan were immunolocalised in tail tendon and collagen fibrils were imaged using transmission electron microscopy (TEM). FGF-2 stimulated tenocyte monolayers displayed elevated Adamts4, Mmp2, 3, 13 mRNA levels compared to WT mice. Non-stimulated tendon Col1A1, Vcan, Bgn, Dcn, Lum, Hspg2, Ltbp1, Ltbp2, Eln and Fbn1 mRNA levels showed no major differences between the two genotypes other than a decline with ageing while LTBP2 expression increased. Eln expression also declined to a greater extent in the perlecan exon 3 null mice (P < 0.05). Type VI collagen and perlecan were immunolocalised in tail tendon and collagen fibrils imaged using transmission electron microscopy (TEM). This indicated a more compact form of collagen localization in the perlecan exon 3 null mice. Collagen fibrils were also smaller by TEM, which may facilitate a more condensed fibril packing accounting for the superior UTS displayed by the perlecan exon 3 null mice. The amplified catabolic phenotype of Hspg2Δ3 - ∕Δ3 - mice may account for the age-dependent decline in GAG observed in tail tendon over 3 to 12 weeks. After Achilles tenotomy Hspg2Δ3 - ∕Δ3 - and WT mice had similar rates of recovery of UTS and TM over 12 weeks post operatively indicating that a deficiency of HS was not detrimental to tendon repair.

17.
J Ultrasound Med ; 37(8): 2075-2081, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29451317

ABSTRACT

Ultrasound (US)-guided microinvasive procedures are defined as those performed via needles without notable scarring. Ten cadaver hands underwent US-guided microinvasive carpal tunnel release using a novel needle-based tool, the micro i-Blade (Summit Medical Products, Inc, Sandy, UT). A US-imaged landmark, the inflexion point of the ligaments distal to the hook of the hamate, was used to position the distal extent of the cut. The transverse carpal ligament was successfully released in all hands without damage to nerves or arteries. In 3 specimens, the fascia between the thenar and hypothenar muscles was partly preserved, whereas the palmar aponeurosis was partly cut in 1 specimen. The micro i-Blade with the cutting knife retracted was also useful as a probe palpated through the palm of the cadaver hand, to test the release of the transverse carpal ligament and to guide the procedure.


Subject(s)
Carpal Tunnel Syndrome/surgery , Median Nerve/surgery , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Ultrasonography, Interventional/methods , Humans , Needles , Surgical Instruments , Wrist Joint
18.
J Spine Surg ; 2(3): 178-184, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27757430

ABSTRACT

BACKGROUND: Commercial fusion cages typically provide support in the central region of the endplate, failing to utilize the increased compressive strength around the periphery. This study demonstrates the increase in compressive strength that can be achieved if the bony periphery of the endplate is loaded. METHODS: Sixteen cadaveric lumbar vertebrae (L1-L5) were randomly divided into two even groups. A different commercial mass produced implant (MPI) was allocated to each group: (I) a Polyether-ether-ketone (PEEK) anterior lumber inter-body fusion (ALIF) MPI; and (II) a titanium ALIF MPI. Uniaxial compression at a displacement rate of 0.5 mm/sec was applied to all vertebrae during two phases: (I) with the allocated MPI situated in the central region of the endplate; (II) with an aluminum plate, designed to load the bony periphery of the endplate. The failure load and mode of failure was recorded. RESULTS: From phase 1 to phase 2, the failure load increased from 1.1±0.4 to 2.9±1.4 kN for group 1; and from 1.3±1.0 to 3.0±1.9 kN for group 2. The increase in strength from phase 1 to phase 2 was statistically significant for each group (group 1: P<0.01, group 2: P<0.05, paired t-test). There was no significant difference between the groups in either phase (P>0.05, t-test). The mode of failure in phase 1 was the implant being forced through the endplate for both groups. In phase 2, the mode of failure was either a fracture of the epiphyseal rim or buckling of the side wall of the vertebral body. CONCLUSIONS: Loading the periphery of the vertebral endplate achieved significant increase in compressive load capacity compared to loading the central region of the endplate. Clinically, this implies that patient-specific implants which load the periphery of the vertebral endplate could decrease the incidence of subsidence and improve surgical outcomes.

19.
Proc Inst Mech Eng H ; 230(7): 668-74, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27098752

ABSTRACT

Peri-prosthetic femoral neck fracture after femoral head resurfacing can be either patient-related or surgical technique-related. The study aimed to develop a patient-specific finite element modelling technique that can reliably predict an optimal implant position and give minimal strain in the peri-prosthetic bone tissue, thereby reducing the risk of peri-prosthetic femoral neck fracture. The subject-specific finite element modelling was integrated with optimization techniques including design of experiments to best possibly position the implant for achieving minimal strain for femoral head resurfacing. Sample space was defined by varying the floating point to find the extremes at which the cylindrical reaming operation actually cuts into the femoral neck causing a notch during hip resurfacing surgery. The study showed that the location of the maximum strain, for all non-notching positions, was on the superior femoral neck, in the peri-prosthetic bone tissue. It demonstrated that varus positioning resulted in a higher strain, while valgus positioning reduced the strain, and further that neutral version had a lower strain.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Femur Head/surgery , Hip Prosthesis , Biomechanical Phenomena , Femoral Neck Fractures/prevention & control , Femur Head/diagnostic imaging , Femur Neck/diagnostic imaging , Femur Neck/physiopathology , Femur Neck/surgery , Finite Element Analysis , Humans , Imaging, Three-Dimensional , Models, Anatomic , Tomography, X-Ray Computed
20.
J Comput Assist Tomogr ; 39(6): 925-35, 2015.
Article in English | MEDLINE | ID: mdl-26418538

ABSTRACT

OBJECTIVE: To assess the accuracy and suitability of dual-energy computed tomography (DECT) in scanning metals used in orthopedic implants. MATERIALS AND METHODS: Four metal phantoms (Cobalt Chrome, Titanium Grade 5, Stainless Steel 316, and Stainless Steel 630), commonly used materials in orthopedic implants, were scanned by conventional, polychromatic CT as well as Gemstone Spectrum Imaging (GSI) DECT, with and without metal artefact reduction software (MARS). Scans were assessed for artefact based on Hounsfield unit values; and surfaces generated, based on a Canny edge detection algorithm. Two separate metal implants were also scanned and assessed for dimensional accuracy. RESULTS: Conventional, polychromatic CT, and GSI DECT (without MARS) scans displayed major beam hardening in the presence of all four metals. The GSI DECT with MARS showed very clear and reproducible boundaries with minimal noise surrounding the metal phantoms. However, geometric analysis found overestimation of the dimensions, volume, and surface area for most of the metal phantoms. Titanium displayed the least artefact, compared to the other metals, in all scan scenarios. CONCLUSIONS: Although metal artefact reduction using GSI DECT looks superior to conventional CT, when measured objectively, it was shown to overestimate geometries and skew dimensions. The GSI DECT with MARS should be used with caution, especially when assessing questions of implant shape or wear.


Subject(s)
Artifacts , Metals , Prostheses and Implants , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Humans , Orthotic Devices , Phantoms, Imaging , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...