Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Article in English | MEDLINE | ID: mdl-35055731

ABSTRACT

This research aims to describe the relationship between resilience and burnout facing COVID-19 pandemics. The sample was n = 831 lecturers and professors of a Mexican public university. This study is a quantitative, non-experimental, cross-sectional, explanatory, and ex post facto research using Structural Equations Modeling with latent variables under the partial least square's method technique. We used the CD-RISC-25 and SBI questionnaires to measure resilience and burnout, respectively. Structural Equations Modeling (SEM-PLS) allowed the visualization of the exogenous variable (resilience) in endogenous variables (dimensions of SBI burnout: E9 guilt, E7 emotional exhaustion, E8 indolence, and E6 work illusion). To this day, there are very few previous studies that jointly analyze in Mexico the characteristics of resilience and burnout in the face of the COVID-19 pandemic. Findings show that resources availability has the strongest correlation with accomplishment in teaching, followed by cynicism and emotional exhaustion. These results have important professional implications.


Subject(s)
Burnout, Professional , COVID-19 , Resilience, Psychological , Burnout, Professional/epidemiology , Burnout, Psychological , Cross-Sectional Studies , Faculty , Humans , Pandemics , SARS-CoV-2 , Surveys and Questionnaires
2.
Article in English | MEDLINE | ID: mdl-34948502

ABSTRACT

This research uses structural equation modeling to determine the influence of uncertainty due to the COVID-19 pandemic as an independent variable in the negative emotional states and resilience (as mediating variables) vs. drug addiction, alcoholism, and suicide ideation as dependent variables in 5557 students from a public state university in Northern Mexico. The five variables are related through eight hypotheses and tested using partial least squares. We used an adapted questionnaire sent by email in May 2020. Findings show that uncertainty facing the COVID-19 pandemic had a direct and significant influence on negative emotional states and a significant inverse effect on resilience; in the trajectory, drug addiction and alcoholism, and suicide ideation are explained.


Subject(s)
Alcoholism , COVID-19 , Substance-Related Disorders , Alcoholism/epidemiology , Humans , Pandemics , SARS-CoV-2 , Suicidal Ideation , Uncertainty
3.
Article in English | MEDLINE | ID: mdl-32756344

ABSTRACT

No previous studies in Mexico have been found that jointly analyze physical and leisure activities as variables related to mental health in police officers. This paper presents research on burnout in Mexican Police officers. The question it answers is: is there any association of burnout with physical and leisure activities and personal profile? A total of 276 police officers (87% men and 13% women) participated. To obtain information, the Spanish Burnout Inventory and the Operational Police Stress questionnaires were used. A cross sectional study design was utilized with tests of validity and reliability, goodness of fit, analysis of variance (ANOVA), and analysis of k-means clusters. Results showed that a high number of policemen had high prevalence of burnout and a high level of mental exhaustion, and that exercise was positively and significantly related to lower burnout risk. Men showed higher risk than women. Results should be considered to improve interventions and occupational health practices in the police force. This paper improves understanding of burnout among policemen and the importance of exercise and leisure activities to alleviate burnout.


Subject(s)
Burnout, Professional , Exercise , Leisure Activities , Police , Burnout, Professional/epidemiology , Cross-Sectional Studies , Female , Humans , Male , Mexico , Police/psychology , Reproducibility of Results , Surveys and Questionnaires
4.
Rev Salud Publica (Bogota) ; 20(1): 110-116, 2018.
Article in English | MEDLINE | ID: mdl-30183893

ABSTRACT

OBJECTIVE: To assess a LED-fluorescence microscopy (LED-FM) capacitation program for the training of laboratory technicians without previous experience in FM. METHODS: We evaluated a teaching program that consists of a three-day course followed by an "in situ" two-month phase in which technicians acquired skills without the help of a FM expert; in order to gain confidence to recognize auramine-stained bacillus, during this phase, technicians examined duplicate slides stained by Ziehl Neelsen (ZN) and FM in a unblinded way. Technicians with acceptable performance, continued with a blinded-training period. Testing panels and rechecking process were used to evaluate proficiency after different length of experience. RESULTS: Post-course panel results showed that 70% of trainees made Low False Positive errors (LFPs). Analysis of two other panels showed that LFPs significantly decreased (Chi-squared test, p<0.05) as the "in situ" training phase progressed. Processing at least three slides/day was associated with acceptable performance. During the blinded-training period, results of the rechecking process showed that sensitivity (96.8%) and specificity (99.8%) levels were satisfactory. CONCLUSION: Moderate training (a three-day course) is not enough to make technicians proficient in LED-FM; however, great ability can be reached after a short "in situ" training phase even without the presence of experienced staff available in field to review doubtful results. Training was more effective in services with a minimum workload of 750 slides/year.


Subject(s)
Medical Laboratory Personnel/education , Microscopy, Fluorescence , Mycobacterium tuberculosis/isolation & purification , Tuberculosis/diagnosis , Argentina , Capacity Building , Clinical Competence , Feasibility Studies , Female , Humans , Male , Microscopy, Fluorescence/methods , Quality Control
5.
Rev. salud pública ; 20(1): 110-116, ene.-feb. 2018. tab
Article in English | LILACS | ID: biblio-962100

ABSTRACT

ABSTRACT Objective To assess a LED-fluorescence microscopy (LED-FM) capacitation program for the training of laboratory technicians without previous experience in FM. Methods We evaluated a teaching program that consists of a three-day course followed by an "in situ" two-month phase in which technicians acquired skills without the help of a FM expert; in order to gain confidence to recognize auramine-stained bacillus, during this phase, technicians examined duplicate slides stained by Ziehl Neelsen (ZN) and FM in a unblinded way. Technicians with acceptable performance, continued with a blinded-training period. Testing panels and rechecking process were used to evaluate proficiency after different length of experience. Results Post-course panel results showed that 70% of trainees made Low False Positive errors (LFPs). Analysis of two other panels showed that LFPs significantly decreased (Chi-squared test, p<0.05) as the "in situ" training phase progressed. Processing at least three slides/day was associated with acceptable performance. During the blinded-training period, results of the rechecking process showed that sensitivity (96.8%) and specificity (99.8%) levels were satisfactory. Conclusion Moderate training (a three-day course) is not enough to make technicians proficient in LED-FM; however, great ability can be reached after a short "in situ" training phase even without the presence of experienced staff available in field to review doubtful results. Training was more effective in services with a minimum workload of 750 slides/year.(AU)


RESUMEN Objetivo Evaluar un programa de capacitación en microscopía de fluorescencia LED (MF-LED) para el entrenamiento de técnicos de laboratorio sin experiencia en MF. Métodos Se evaluó un programa de capacitación que consiste en un curso de tres días seguido de dos meses de entrenamiento «in situ¼, en donde los técnicos adquirieron habilidades sin presencia de un experto en la práctica diaria; para alcanzar confianza en el reconocimiento del bacilo, los técnicos, durante estos meses, examinaron en forma «no cegada¼ extendidos duplicados teñidos por Ziehl Neelsen (ZN) y MF. Aquellos laboratoristas que lograron rendimiento aceptable continuaron su entrenamiento «a ciegas¼. Su desempeño fue evaluado en distintos períodos del entrenamiento mediante paneles de láminas y relectura de extendidos. Resultados Los resultados de un panel posterior al curso mostraron que 70% de los participantes cometieron errores falsos positivos bajos (FPB). Dos paneles posteriores evidenciaron que los FPB disminuían significativamente (prueba de Chi cuadrado, p<0.05) a medida que el entrenamiento avanzaba. El procesamiento de al menos tres extendidos/ día se asoció con desempeño aceptable. Durante el período a ciegas, la relectura de láminas evidenció que la sensibilidad (96,8%) y especificidad (99,8%) fueron satisfactorias. Conclusiones Una capacitación moderada (curso de tres días) no es suficiente para adquirir competencia en MF-LED; sin embargo, se puede alcanzar habilidad después de una corta capacitación «in situ¼, incluso si no hay personal con experiencia disponible en el servicio para revisar los resultados dudosos diariamente. El entrenamiento fue más efectivo en servicios con carga de trabajo mínima de 750 extendidos/año.(AU)


Subject(s)
Humans , Training Courses , Laboratory Personnel/education , Argentina , Multicenter Study , Analysis of Situation , Microscopy, Fluorescence
6.
Biomédica (Bogotá) ; 37(2): 164-174, abr.-jun. 2017. tab
Article in English | LILACS | ID: biblio-888456

ABSTRACT

ABSTRACT Introduction: Light-emitting diode fluorescence microscopy (LED-FM) has been endorsed by the World Health Organization (WHO) for tuberculosis diagnosis, but its accuracy in HIV-infected patients remains controversial, and only some few studies have explored procedural factors that may affect its performance. Objective: To evaluate the performance of LED-FM for tuberculosis diagnosis in patients with and without HIV infection using a newer, less expensive LED lamp. Materials and methods: We compared the performance of LED-FM and Ziehl-Neelsen (ZN) microscopy on respiratory specimen smears from tuberculosis (TB) suspects and patients on treatment examined by different technicians blinded for HIV-status and for the result of the comparative test. We analyzed the effect of concentrating specimens prior to microscopy using different examination schemes and user-appraisal of the LED device. Results: Of the 6,968 diagnostic specimens collected, 869 (12.5%) had positive Mycobacterium tuberculosis cultures. LED-FM was 11.4% more sensitive than ZN (p<0.01). Among HIV-positive TB patients, sensitivity differences between LED-FM and ZN (20.6%) doubled the figure obtained in HIV-negative patients or in those with unknown HIV status (9.3%). After stratifying by direct and concentrated slides, the superiority of LED-FM remained. High specificity values were obtained both with LED-FM (99.9%) and ZN (99.9%).The second reading of a sample of slides showed a significantly higher positive detection yield using 200x magnification (49.4 %) than 400x magnification (33.8%) (p<0.05). The LED-device had a very good acceptance among the technicians. Conclusion: LED-FM better performance compared with ZN in HIV-infected patients and user-appraisal support the rapid roll-out of LED-FM. Screening at 200x magnification was essential to achieve LED-FM increased sensitivity.


RESUMEN Introducción. La microscopía de fluorescencia con lámpara LED (MF-LED) ha sido recomendada por la Organización Mundial de la Salud (OMS) para el diagnóstico de la tuberculosis, pero su precisión en pacientes con HIV continúa siendo controversial y en pocos estudios se han explorado los factores metodológicos que pueden afectar su utilidad. Objetivo. Evaluar el rendimiento de la MF-LED en el diagnóstico de la tuberculosis en pacientes con HIV y sin él mediante un novedoso dispositivo LED. Materiales y métodos. Se comparó el rendimiento de la MF-LED y la microscopía en frotis de muestras respiratorias con tinción de Ziehl-Neelsen (M-ZN) examinados por técnicos cegados en cuanto al estado de HIV y el resultado de la prueba comparativa. Se analizó el efecto de concentrar muestras antes de la microscopía, usar diferentes esquemas de observación y la valoración con el dispositivo LED. Resultados. De las 6.968 muestras recolectadas, 869 (12,5 %) resultaron con cultivo positivo para Mycobacterium tuberculosis. La MF-LED fue 11,4 % más sensible que la M-ZN (p<0,01). Entre los pacientes con tuberculosis positivos para HIV, la diferencia de sensibilidad entre la MF-LED y la M-ZN (20,6 %) duplicó la cifra obtenida en pacientes negativos para HIV o con estatus desconocido (9,3 %). Al estratificar los frotis en directos y concentrados, se mantuvo la superioridad de la MF-LED. Las especificidades de la MF-LED (99,9 %) y la M-ZN (99,9 %) resultaron elevadas. La lectura de una muestra de frotis mostró una positividad significativamente mayor con un aumento de 200X (49,4 %) que con uno de 400X (33,8 %) (p<0,05). El dispositivo LED tuvo una buena aceptación entre los técnicos. Conclusión. Debido al mejor desempeño de la MF-LED comparada con la M-ZN en pacientes con HIV y su fácil utilización, se recomienda su adopción. La utilización del aumento de 200X fue esencial para el incremento de la sensibilidad de la MF-LED.


Subject(s)
Humans , Sputum/microbiology , Tuberculosis/diagnosis , Tuberculosis/microbiology , Tuberculosis, Pulmonary/diagnosis , Tuberculosis, Pulmonary/microbiology , HIV Infections/complications , Argentina , Sensitivity and Specificity , Laboratories , Microscopy, Fluorescence
7.
Biomedica ; 37(2): 164-174, 2017 06 01.
Article in Spanish | MEDLINE | ID: mdl-28527280

ABSTRACT

INTRODUCTION: Light-emitting diode fluorescence microscopy (LED-FM) has been endorsed by the World Health Organization (WHO) for tuberculosis diagnosis, but its accuracy in HIV-infected patients remains controversial, and only some few studies have explored procedural factors that may affect its performance. OBJECTIVE: To evaluate the performance of LED-FM for tuberculosis diagnosis in patients with and without HIV infection using a newer, less expensive LED lamp. MATERIALS AND METHODS: We compared the performance of LED-FM and Ziehl-Neelsen (ZN) microscopy on respiratory specimen smears from tuberculosis (TB) suspects and patients on treatment examined by different technicians blinded for HIV-status and for the result of the comparative test. We analyzed the effect of concentrating specimens prior to microscopy using different examination schemes and user-appraisal of the LED device. RESULTS: Of the 6,968 diagnostic specimens collected, 869 (12.5%) had positive Mycobacterium tuberculosis cultures. LED-FM was 11.4% more sensitive than ZN (p;0.01). Among HIV-positive TB patients, sensitivity differences between LED-FM and ZN (20.6%) doubled the figure obtained in HIVnegative patients or in those with unknown HIV status (9.3%). After stratifying by direct and concentrated slides, the superiority of LED-FM remained. High specificity values were obtained both with LED-FM(99.9%) and ZN (99.9%).The second reading of a sample of slides showed a significantly higher positive detection yield using 200x magnification (49.4 %) than 400x magnification (33.8%) (p;0.05). The LEDdevice had a very good acceptance among the technicians. CONCLUSION: LED-FM better performance compared with ZN in HIV-infected patients and user-appraisal support the rapid roll-out of LED-FM. Screening at 200x magnification was essential to achieve LEDFM increased sensitivity.


Subject(s)
HIV Infections/complications , Sputum/microbiology , Tuberculosis, Pulmonary/diagnosis , Tuberculosis, Pulmonary/microbiology , Tuberculosis/diagnosis , Tuberculosis/microbiology , Argentina , Humans , Laboratories , Microscopy, Fluorescence , Sensitivity and Specificity
8.
Rev Argent Microbiol ; 48(2): 122-7, 2016.
Article in English | MEDLINE | ID: mdl-27291283

ABSTRACT

Blinded rechecking is a method proposed for external quality assurance (EQA) of auramine-stained acid-fast bacilli (AFB) smears using fluorescence microscopy (FM), however, this procedure is not well developed and slides fading over time could compromise its implementation. Since bleaching of fluorescent molecules involves temperature-dependent chemical reactions, it is likely that low temperatures could slow down this process. We stored auramine-stained slides under different environmental conditions, including -20°C, and examined them over time. The slides stored in all the environments faded. At -20°C, fading was not reduced in relation to room temperature. Restaining and re-examining smears after five months showed that the slides containing saliva and storage at -20°C were associated with failure in AFB reappearance. In conclusion, the practice of freezing slides until they are viewed should be discouraged as it has a negative effect on blinded rechecking by reducing reading concordance after restaining. Specimen quality should be considered when interpreting FM-EQA results.


Subject(s)
Benzophenoneidum/radiation effects , Fluorescent Dyes/radiation effects , Microscopy, Fluorescence/methods , Photobleaching , Quality Assurance, Health Care/methods , Sputum/microbiology , Staining and Labeling/methods , Tuberculosis/diagnosis , Argentina , Benzophenoneidum/analysis , Cryopreservation , Feasibility Studies , Fluorescent Dyes/analysis , Humans , Lighting , Microscopy, Fluorescence/instrumentation , Observer Variation , Predictive Value of Tests , Preservation, Biological/methods , Reproducibility of Results , Single-Blind Method , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...