Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
2.
Kardiologiia ; 60(10): 4-12, 2020 Sep 16.
Article in Russian | MEDLINE | ID: mdl-33228499

ABSTRACT

Recommendation provides information to employees of medical departments at any level and primarily primary care about the possible proarrhythmic and adverse effects of drugs used for the treatment of COVID-19 patients and the features of therapy for COVID-19 patients with heart rhythm and conduction disorders receiving permanent antiarrhythmic therapy.


Subject(s)
Anti-Arrhythmia Agents , Coronavirus Infections , Pandemics , Pneumonia, Viral , Anti-Arrhythmia Agents/adverse effects , Arrhythmias, Cardiac/chemically induced , Arrhythmias, Cardiac/therapy , Betacoronavirus , COVID-19 , Coronavirus Infections/drug therapy , Humans , SARS-CoV-2 , COVID-19 Drug Treatment
3.
JAMA ; 321(13): 1261-1274, 2019 04 02.
Article in English | MEDLINE | ID: mdl-30874766

ABSTRACT

Importance: Catheter ablation is effective in restoring sinus rhythm in atrial fibrillation (AF), but its effects on long-term mortality and stroke risk are uncertain. Objective: To determine whether catheter ablation is more effective than conventional medical therapy for improving outcomes in AF. Design, Setting, and Participants: The Catheter Ablation vs Antiarrhythmic Drug Therapy for Atrial Fibrillation trial is an investigator-initiated, open-label, multicenter, randomized trial involving 126 centers in 10 countries. A total of 2204 symptomatic patients with AF aged 65 years and older or younger than 65 years with 1 or more risk factors for stroke were enrolled from November 2009 to April 2016, with follow-up through December 31, 2017. Interventions: The catheter ablation group (n = 1108) underwent pulmonary vein isolation, with additional ablative procedures at the discretion of site investigators. The drug therapy group (n = 1096) received standard rhythm and/or rate control drugs guided by contemporaneous guidelines. Main Outcomes and Measures: The primary end point was a composite of death, disabling stroke, serious bleeding, or cardiac arrest. Among 13 prespecified secondary end points, 3 are included in this report: all-cause mortality; total mortality or cardiovascular hospitalization; and AF recurrence. Results: Of the 2204 patients randomized (median age, 68 years; 37.2% female; 42.9% had paroxysmal AF and 57.1% had persistent AF), 89.3% completed the trial. Of the patients assigned to catheter ablation, 1006 (90.8%) underwent the procedure. Of the patients assigned to drug therapy, 301 (27.5%) ultimately received catheter ablation. In the intention-to-treat analysis, over a median follow-up of 48.5 months, the primary end point occurred in 8.0% (n = 89) of patients in the ablation group vs 9.2% (n = 101) of patients in the drug therapy group (hazard ratio [HR], 0.86 [95% CI, 0.65-1.15]; P = .30). Among the secondary end points, outcomes in the ablation group vs the drug therapy group, respectively, were 5.2% vs 6.1% for all-cause mortality (HR, 0.85 [95% CI, 0.60-1.21]; P = .38), 51.7% vs 58.1% for death or cardiovascular hospitalization (HR, 0.83 [95% CI, 0.74-0.93]; P = .001), and 49.9% vs 69.5% for AF recurrence (HR, 0.52 [95% CI, 0.45-0.60]; P < .001). Conclusions and Relevance: Among patients with AF, the strategy of catheter ablation, compared with medical therapy, did not significantly reduce the primary composite end point of death, disabling stroke, serious bleeding, or cardiac arrest. However, the estimated treatment effect of catheter ablation was affected by lower-than-expected event rates and treatment crossovers, which should be considered in interpreting the results of the trial. Trial Registration: ClinicalTrials.gov Identifier: NCT00911508.


Subject(s)
Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Catheter Ablation , Heart Arrest/prevention & control , Hemorrhage/prevention & control , Stroke/prevention & control , Aged , Anti-Arrhythmia Agents/adverse effects , Atrial Fibrillation/complications , Atrial Fibrillation/mortality , Catheter Ablation/adverse effects , Female , Heart Arrest/etiology , Hemorrhage/etiology , Hospitalization/statistics & numerical data , Humans , Intention to Treat Analysis , Kaplan-Meier Estimate , Male , Middle Aged , Recurrence , Registries , Risk Factors , Stroke/etiology
4.
J Interv Card Electrophysiol ; 34(3): 325-32, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22426601

ABSTRACT

The recent introduction of subcutaneous implantable cardioverter defibrillator (S-ICD) has raised attention about the potential of this technology for clinical use in daily clinical practice. We review the methods and results of the four studies conducted in humans for approval of this innovative technology for daily practice. Two studies using a temporary S-ICD system (acute human studies) were conducted to search for an appropriate lead configuration and energy requirements. For this purpose, 4 S-ICD configurations were tested in 78 patients at the time of transvenous (TV)-ICD implantation. The optimal configuration was tested in 49 more patients to comparatively assess the subcutaneous defibrillation threshold (S-DFT) versus the standard TV-ICD. Long-term implants were evaluated in 55 patients using an implanted system (chronic human study). The acute humans studies led to an optimal S-ICD configuration comprising a parasternal electrode and left anterolateral thoracic pulse generator. Both configurations successfully terminated 98% of induced ventricular fibrillation (VF), but significantly higher energy levels were required with S-ICD than with TV-ICD systems (36.6 ± 19.8 J vs. 11.1 ± 8.5 J). In the chronic study, all 137 VF episodes induced at time of implant were detected with a 98% conversion rate. Two pocket infections and four lead revisions were required during 10 ± 1 months of follow-up. During this period, survival was 98%, and 12 spontaneous ventricular tachyarrhythmias were detected and treated by the device. These data show that the S-ICD systems here consistently detected and converted VF induced at time of implant as well as sustained ventricular tachyarrhythmias occurring during follow-up (248).


Subject(s)
Defibrillators, Implantable , Electric Countershock/instrumentation , Ventricular Fibrillation/therapy , Electrocardiography , Electrodes, Implanted , Equipment Design , Humans , Ventricular Fibrillation/physiopathology
5.
Asian Cardiovasc Thorac Ann ; 18(6): 529-35, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21149400

ABSTRACT

Radiofrequency ablation of atrioventricular nodal reentrant tachycardia is commonly guided by slow and sharp bipolar potentials of the atrioventricular slow nodal pathway. We optimized the morphology of the guiding potential by unipolar mapping of the slow nodal pathway. We identified a novel unipolar dual-component atrial electrogram at the anterior limb of the coronary sinus ostium. The first component was a positive delta-wave type that corresponded to the isoelectric phase on a bipolar electrogram. The second component had fast biphasic morphology and corresponded to the R wave on a bipolar atrial electrogram. Of 104 consecutive patients with typical atrioventricular nodal reentrant tachycardia, 51 were treated with ablation guided by the novel potential, and 53 underwent ablation using the conventional technique. There was no recurrence of tachycardia in any of these patients. In those treated by the novel potential, there was significantly less radiofrequency power applied and a shorter duration of application than in patients treated by the traditional approach. The novel approach to mapping and ablation of the slow nodal pathway in atrioventricular nodal reentrant tachycardia guided by unipolar recording was safe and effective, and comparable to the traditional technique.


Subject(s)
Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac , Heart Conduction System/physiopathology , Tachycardia, Atrioventricular Nodal Reentry/surgery , Action Potentials , Adult , Case-Control Studies , Catheter Ablation/adverse effects , Electrocardiography , Female , Humans , Male , Middle Aged , Moscow , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Time Factors , Treatment Outcome
6.
N Engl J Med ; 363(1): 36-44, 2010 Jul 01.
Article in English | MEDLINE | ID: mdl-20463331

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, we conducted two short-term clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation threshold in comparison with that of the standard transvenous ICD. Then we evaluated the long-term use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS: The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (+/-SD) energy requirement (36.6+/-19.8 J vs. 11.1+/-8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65-J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10+/-1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS: In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.)


Subject(s)
Defibrillators, Implantable , Heart Diseases/therapy , Adult , Aged , Aged, 80 and over , Electrocardiography , Electrodes, Implanted , Equipment Design , Female , Heart Diseases/physiopathology , Humans , Male , Middle Aged , Pilot Projects , Stroke Volume , Young Adult
SELECTION OF CITATIONS