1.
Surg Infect (Larchmt) ; 23(3): 280-287, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35172116

ABSTRACT

Background: Debridement, antibiotic agents, and implant retention (DAIR) is a currently accepted approach for the treatment of early prosthetic joint infections (PJI). The success of a DAIR procedure has shown variable results throughout the published literature. Scoring systems such as the Kidney, Liver, Index surgery, Cemented prosthesis, and C-reactive protein value (KLIC) score for the selection of patients that are likely to benefit from DAIR have proved to be helpful in decision making. Our study aims to further validate the KLIC score using a large external multicentric cohort and to evaluate other risk factors for failure. Patients and Methods: A retrospective analysis of patients with an early acute PJI who were treated with DAIR and recorded in a database of eight Spanish university hospitals was performed. According to pre-operative variables of the KLIC study, patients were categorized into five groups: group A, ≤2 points; group B, 2.5-3.5 points; group C, 4-5 points; group D, 5.5-6.5 points; and group E, ≥7 points. Failure rates were compared between groups at 60 days and after 60 days of DAIR. Further variables for risk of failure were also analyzed. Results: A total of 455 patients with early acute PJI were included in the analyses. At 60 days, patients presenting with pre-operative elevated C-reactive protein serum levels, Staphylococcus aureus, and polymicrobial infections were associated with failure. Failure rates recorded were 12% for group A (n = 210), 18% for group B (n = 83), 26% for group C (n = 89), 24% for group D (n = 66), and 0% for group E (n = 7). Univariable analysis between consecutive groups of the KLIC score showed no differences for failure before 60 days of the DAIR procedure. Scheduled surgery and having the procedure performed by a specialized unit were also identified as important factors for DAIR success. Conclusions: Our results suggest the KLIC score was not useful for predicting failure in our cohort. Furthermore, our results indicate a specialized unit should conduct DAIR procedures.


Subject(s)
Prosthesis-Related Infections , Anti-Bacterial Agents/therapeutic use , Debridement , Humans , Prosthesis-Related Infections/surgery , Retrospective Studies , Risk Factors , Treatment Outcome
2.
Acta Orthop Belg ; 87(3): 393-399, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34808711

ABSTRACT

This study investigates the clinical and radiological results of a tapered femoral stem (Corail®) and uncemented threaded acetabular cups (Tropic®) and in addition an analysis of the complications and retrieved implants was conducted. Between January 1990 and September 1998, 301 total hips arthroplasties in 268 patients were implanted. 78 patients (87 hips) had died and 9 patients (12 hips) had been lost to follow-up, leaving at the time of the latest follow-up 180 patients (202 hips). The mean age at surgery was 56,1 (27-75) years. Of the 154 unrevised hips, the median Harris and Merle d'Aubigne and Postel hip scores were 83,3 points and 15,3 points respectively at the latest follow-up. The median follow-up time was 16.9 years (10,4-25). No femoral component was revised for aseptic loosening ; osteolysis was observed in the 9,5% of the implants (13 stems). 48 hips (23%) were revised and 27 cups (56,2%) needed revision surgery because of massive polyethylene wear. Pelvic osteolysis was found out in 80 cups (58,8%). 87 hips (63,9%) showed signs of a progressive wear of the liner, more than 2mm in 48 hips. Kaplan-Meier survivorship analysis at 15 years follow-up was 81.2% with revision for any reason (85.8% for mechanical or radiographic loosening). High rates of polyethylene wear and the high prevalence of pelvic osteolysis are serious matters in these types of implants with high rates of revision at 15 years follow-up so we decided to abandon the concept of a threaded cup design in favor of a press-fit acetabular cup.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/diagnostic imaging , Acetabulum/surgery , Arthroplasty, Replacement, Hip/adverse effects , Follow-Up Studies , Humans , Prosthesis Design , Prosthesis Failure , Reoperation , Treatment Outcome