ABSTRACT

AIMS: To assess the hypothesis that fluoroscopically-guided helical needle transendocardial delivery of autologous bone marrow (ABM) mononuclear cells (MNCs) in chronic post myocardial infarction patients is safe and improves ejection fraction (EF). METHODS AND RESULTS: Twenty ischaemic heart failure patients with an EF ≤40% were enrolled. ABMMNCs were prepared, counted for CD34+ and CD133+ content, and delivered percutaneously to the heart at 5 to 10 peri-infarct sites. Two-dimensional (2D) transthoracic echocardiography, EF measurements, Holter, and exercise tolerance time (ETT) were performed at baseline, one week (wk), and 6, 12, and 24 months (mo). 96±29 million ABMMNCs were injected into 8.5±2.6 peri-infarct sites over 42±17 minutes (n=20). There were no adverse events associated with the catheter-based cell transplantation procedure or significant increases in ventricular events on Holter. EF improved over baseline from 34.9±4.3% to 41.9±5.1% at 12 mo to 42.2±7.1% (p=0.00005) at 24 mo. ETT improvements were statistically significant from 246±113 sec to 373±183 sec at 12 mo and 371±181 sec at 24 mo (p=0.006). CONCLUSIONS: ABMMNCs delivered with the helical needle transendocardial catheter was safe in this uncontrolled open label study. Increased EF and ETT support the safety of the procedure and technologies involved and warrant additional investigation.


Subject(s)
Bone Marrow Transplantation , Heart Failure/surgery , Myocardial Infarction/surgery , Aged , Argentina , Bone Marrow Transplantation/adverse effects , Bone Marrow Transplantation/instrumentation , Catheters , Echocardiography , Electrocardiography, Ambulatory , Equipment Design , Exercise Test , Exercise Tolerance , Female , Fluoroscopy , Heart Failure/diagnosis , Heart Failure/etiology , Heart Failure/physiopathology , Humans , Injections , Male , Middle Aged , Myocardial Infarction/complications , Myocardial Infarction/diagnosis , Myocardial Infarction/physiopathology , Needles , Radiography, Interventional , Recovery of Function , Stroke Volume , Time Factors , Transplantation, Autologous , Treatment Outcome , Ventricular Function, Left
2.
Am Heart J ; 154(1): 79.e1-7, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17584556

ABSTRACT

BACKGROUND: Cell therapy has shown benefit in preclinical and clinical studies, although debate continues on the mechanism of action and the most appropriate methods for performing such therapies. We assessed the hypothesis that helical needle transendocardial (TE) delivery of autologous bone marrow (ABM) mononuclear cells around regions of hypo- or akinesia in patients after chronic myocardial infarction (MI) would be safe and possibly improve ejection fraction (EF). METHODS AND RESULTS: Ten stable post-MI patients with an EF <40% were enrolled. Autologous bone marrow cells were aspirated from the iliac crest and delivered percutaneously with a TE helical needle catheter. A total of 86 x 10(6) cells were injected into 7.1 +/- 3.1 sites around the infarct to target the peri-infarct zones. Two-dimensional echocardiographic left ventricle EF measurements, 24-hour Holter, and exercise tolerance testing were performed at baseline, day of procedure, 1 and 12 weeks, and 6 and 12 months. There were no adverse events associated with the catheter-based cell transplantation procedure. At 6 and 12 months, all patients showed an improvement in left ventricle EF over baseline (35.2 +/- 4.6 to 40.8 +/- 4.5, P = .003 at 6 months; 35.2 +/- 4.6 to 42.3 +/- 5.1, P = .0001 at 12 months). CONCLUSIONS: Autologous bone marrow cells delivered with the helical needle TE catheter was safe in this small uncontrolled study in patients with chronic MI. Increased EF and other positive data trends support continued development of this therapeutic strategy in larger controlled trials.


Subject(s)
Bone Marrow Transplantation/instrumentation , Bone Marrow Transplantation/methods , Myocardial Infarction/therapy , Aged , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Bone Marrow Transplantation/adverse effects , Catheterization , Chronic Disease , Exercise Test , Exercise Tolerance , Female , Follow-Up Studies , Heart Failure/etiology , Humans , Male , Middle Aged , Needles , Pilot Projects , Transplantation, Autologous/instrumentation , Transplantation, Autologous/methods