Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 160: 721-728, 2016 Nov 01.
Article in English | MEDLINE | ID: mdl-27591668

ABSTRACT

We present a new chemistry to determine nitrites implemented in a microfluidic paper-based analytical device (µPAD). The device is fabricated in cellulose paper with a sample reception area and three replicate detection areas with recognition chemistry immobilized by adsorption. The method involves the use of nitrite in an acid medium reaction to generate nitrous acid, which produces the oxidation of s-dihydrotetrazine: 1,2-dihydro-3,6-bis(3,5-dimethyl-1H-pyrazol-1-yl)-1,2,4,5-tetrazine (DHBPTz), which change the detection zone from colorless to pink. We used a digital camera and smartphone for the quantitative analysis of nitrite with the color coordinate S of the HSV color space as the analytical parameter. Parameters such as concentration and volume of s-dihydrotetrazine, pH, sample volume and reaction time were studied. The detection limit for this method is 1.30µM nitrite. To estimate the selectivity of the method an interference study of common ions in water samples was performed. The procedure was applied to natural water and compared with reference procedures.

2.
Anal Bioanal Chem ; 408(11): 3013-20, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26869344

ABSTRACT

A portable reconfigurable platform for copper (Cu(II)) determination based on luminescent carbon dot (Cdots) quenching is described. The electronic setup consists of a light-emitting diode (LED) as the carbon dot optical exciter and a photodiode as a light-to-current converter integrated in the same instrument. Moreover, the overall analog conditioning is simply performed with one integrated solution, a field-programmable analog array (FPAA), which makes it possible to reconfigure the filter and gain stages in real time. This feature provides adaptability to use the platform as an analytical probe for carbon dots coming from different batches with some variations in luminescence characteristics. The calibration functions obtained that fit a modified Stern-Volmer equation were obtained using luminescence signals from Cdots quenching by Cu(II). The analytical applicability of the reconfigurable portable instrument for Cu(II) using Cdots has been successfully demonstrated in tap water analysis.


Subject(s)
Carbon/chemistry , Copper/analysis , Luminescence , Reference Standards , X-Ray Diffraction
3.
Nanoscale Res Lett ; 9(1): 410, 2014.
Article in English | MEDLINE | ID: mdl-25242902

ABSTRACT

We report the monitoring of porous silicon (pSi) degradation in aqueous solutions using a consumer-grade digital camera. To facilitate optical monitoring, the pSi samples were prepared as one-dimensional photonic crystals (rugate filters) by electrochemical etching of highly doped p-type Si wafers using a periodic etch waveform. Two pSi formulations, representing chemistries relevant for self-reporting drug delivery applications, were tested: freshly etched pSi (fpSi) and fpSi coated with the biodegradable polymer chitosan (pSi-ch). Accelerated degradation of the samples in an ethanol-containing pH 10 aqueous basic buffer was monitored in situ by digital imaging with a consumer-grade digital camera with simultaneous optical reflectance spectrophotometric point measurements. As the nanostructured porous silicon matrix dissolved, a hypsochromic shift in the wavelength of the rugate reflectance peak resulted in visible color changes from red to green. While the H coordinate in the hue, saturation, and value (HSV) color space calculated using the as-acquired photographs was a good monitor of degradation at short times (t < 100 min), it was not a useful monitor of sample degradation at longer times since it was influenced by reflections of the broad spectral output of the lamp as well as from the narrow rugate reflectance band. A monotonic relationship was observed between the wavelength of the rugate reflectance peak and an H parameter value calculated from the average red-green-blue (RGB) values of each image by first independently normalizing each channel (R, G, and B) using their maximum and minimum value over the time course of the degradation process. Spectrophotometric measurements and digital image analysis using this H parameter gave consistent relative stabilities of the samples as fpSi > pSi-ch.

4.
Chem Commun (Camb) ; 49(11): 1103-5, 2013 Feb 04.
Article in English | MEDLINE | ID: mdl-23283251

ABSTRACT

Carbon dots were synthesized by a simple and green strategy for selective and sensitive Cu(2+) ion detection using both down and upconversion fluorescence. These fluorescent nanosensors show low cytotoxicity and are applied for intracellular sensing and imaging of Cu(2+) in biological systems.


Subject(s)
Carbon/chemistry , Copper/analysis , Nanoparticles/chemistry , Animals , Carbon/pharmacology , Fluorescence , Green Chemistry Technology , Mice , NIH 3T3 Cells
SELECTION OF CITATIONS
SEARCH DETAIL
...