Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
EuroIntervention ; 19(10): e844-e855, 2023 Dec 04.
Article in English | MEDLINE | ID: mdl-37860860

ABSTRACT

BACKGROUND: In the prospective, multicentre, randomised TARGET All Comers study, percutaneous coronary intervention (PCI) with the FIREHAWK biodegradable-polymer sirolimus-eluting stent (BP-SES) was non-inferior to the durable-polymer everolimus-eluting stent (DP-EES) for the primary endpoint of target lesion failure (TLF) at 12 months. AIMS: We aimed to report the final study outcomes at 5 years. METHODS: Patients referred for PCI were randomised to receive either a BP-SES or DP-EES in a 1:1 ratio in 10 European countries. Randomisation was stratified by centre and ST-elevation myocardial infarction (STEMI) presentation, and clinical follow-up extended to 5 years. The primary endpoint was TLF (composite of cardiac death, target vessel myocardial infarction [MI], or ischaemia-driven target lesion revascularisation). Secondary endpoints included patient-oriented composite events (POCE; composite of all-cause death, all MI, or any revascularisation and its components). RESULTS: From December 2015 to October 2016, 1,653 patients were randomly assigned to the BP-SES or DP-EES groups, of which 93.8% completed 5-year clinical follow-up or were deceased. At 5 years, TLF occurred in 17.1% of the BP-SES group and in 16.3% of the DP-EES group (p=0.68). POCE occurred in 34.0% of the BP-SES group and 32.7% of the DP-EES group (p=0.58). Revascularisation was the most common POCE, occurring in 19.3% of patients receiving BP-SES and 19.2% receiving DP-EES, of which less than one-third was ischaemia-driven target lesion-related. In the landmark analysis, there were no differences in the rates of TLF and POCE between groups from 1 to 5 years, and these results were consistent across all subgroups. CONCLUSIONS: In an all-comers population requiring stent implantation for myocardial ischaemia, the BP-SES was non-inferior to the DP-EES for the primary endpoint of TLF at 12 months, and results were sustained at 5 years, confirming the long-term safety and efficacy of the FIREHAWK BP-SES.


Subject(s)
Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Sirolimus , Drug-Eluting Stents/adverse effects , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Treatment Outcome , Absorbable Implants , Everolimus , Myocardial Infarction/etiology , Polymers
2.
Catheter Cardiovasc Interv ; 98(3): 503-510, 2021 09.
Article in English | MEDLINE | ID: mdl-33029937

ABSTRACT

OBJECTIVES: This final report from the REMEDEE Registry assessed the long-term safety and efficacy of the dual-therapy COMBO stent in a large unselected patient population. BACKGROUND: The bio-engineered COMBO stent (OrbusNeich Medical BV, The Netherlands) is a dual-therapy pro-healing stent. Data of long-term safety and efficacy of the this stent is lacking. METHODS: The prospective, multicenter, investigator-initiated REMEDEE Registry evaluated clinical outcomes after COMBO stent implantation in daily clinical practice. One thousand patients were enrolled between June 2013 and March 2014. RESULTS: Five-year follow-up data were obtained in 97.2% of patients. At 5-years, target lesion failure (TLF) (composite of cardiac death, target-vessel myocardial infarction, or target lesion revascularization) was present in 145 patients (14.8%). Definite or probable stent thrombosis (ST) occurred in 0.9%, with no additional case beyond 3-years of follow-up. In males, 5-year TLF-rate was 15.6 versus 12.6% in females (p = .22). Patients without diabetes mellitus (DM) had TLF-rate of 11.4%, noninsulin-treated DM 22.7% (p = .001) and insulin-treated DM 41.2% (p < .001). Patients presenting with non-ST segment elevation acute coronary syndrome (NSTE-ACS) had higher incidence of TLF compared to non-ACS (20.4 vs. 13.3%; p = .008), while incidence with STE-ACS was comparable to non-ACS (10.7 vs. 13.3%; p = .43). CONCLUSION: Percutaneous coronary intervention with the dual-therapy COMBO stent in unselected patient population shows low rates of TLF and ST to 5 years. Remarkably, no case of ST was noted beyond 3 years.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Female , Humans , Male , Prospective Studies , Prosthesis Design , Registries , Risk Factors , Stents , Time Factors , Treatment Outcome
3.
Cardiovasc Revasc Med ; 21(5): 567-570, 2020 05.
Article in English | MEDLINE | ID: mdl-31662276

ABSTRACT

BACKGROUND: Data of long-term safety and efficacy of the COMBO dual-therapy stent is lacking. REMEDEE Registry evaluated the COMBO stent and showed low clinical event rates up to 3 year. We report the clinical outcomes at 4-year follow-up of this registry. METHODS: The REMEDEE Registry is a prospective, multicenter registry with minimal exclusion criteria, evaluating clinical outcomes after treatment with the COMBO stent. A 1000 patients were enrolled between June 2013 and March 2014. Target lesion failure (TLF), defined as a composite of cardiac death, target-vessel myocardial infarction (TV-MI) and target lesion revascularization (TLR), at 4-year follow-up was the primary focus of this analysis. RESULTS: Four-year follow-up data were obtained in 97.3% of patients. TLF was present in 117 patients (11.9%). Cardiac death occurred in 45 patients (4.6%), TV-MI was observed in 25 patients (2.6%) and TLR was performed in 73 patients (7.5%). Of the 7.5% TLR at 4 years, 1.5% were beyond 2 years. Definite ST was seen in 7 patients (0.7%) and probable ST in 1 (0.1%). No definite or probable ST occurred between 3 and 4 years follow-up. At 4-year follow-up, 93.1% of patients were free of ischemic symptoms. CONCLUSION: This registry showed excellent 4-year results after COMBO stent placement, with no ST beyond 3 years.


Subject(s)
Acute Coronary Syndrome/therapy , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/mortality , Aged , Cause of Death , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Europe , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Product Surveillance, Postmarketing , Prospective Studies , Prosthesis Design , Recurrence , Registries , Risk Factors , Time Factors , Treatment Outcome
5.
JACC Cardiovasc Interv ; 12(17): 1679-1687, 2019 09 09.
Article in English | MEDLINE | ID: mdl-31129092

ABSTRACT

OBJECTIVES: The aim of this study was to assess the 2-year clinical outcomes of the Firehawk stent (Shanghai MicroPort Medical Group, Shanghai, China), a novel abluminal groove-filled biodegradable-polymer sirolimus-eluting coronary stent, compared with XIENCE (Abbott Vascular, Santa Clara, California), a durable-polymer everolimus-eluting coronary stent. BACKGROUND: The long-term outcomes of the Firehawk stent have not been evaluated beyond 1 year in a randomized all-comers clinical trial. METHODS: The TARGET All Comers study is a prospective, multicenter, all-comers, randomized, noninferiority trial conducted in Europe. A total of 1,653 patients were randomly assigned to undergo implantation of either the Firehawk or the XIENCE stent. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS: At 2-year follow-up, the incidence of target lesion failure was 8.7% in the Firehawk group versus 8.6% in the XIENCE group (p = 0.92). The event rates of individual components of the primary endpoint were comparable for the 2 groups. Landmark analyses between 1- and 2-year follow-up revealed no statistically significant difference of TLF for the Firehawk versus the XIENCE stent. Beyond 1 year, very late definite or probable stent thrombosis occurred in 3 patients (0.4%) in the Firehawk group and in 7 patients (0.9%) in the XIENCE group (p = 0.34). CONCLUSIONS: The 2-year follow-up of the TARGET All Comers study confirms comparable safety and efficacy profiles of the Firehawk and XIENCE stents.


Subject(s)
Absorbable Implants , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Polymers/chemistry , Sirolimus/administration & dosage , Aged , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Dual Anti-Platelet Therapy , Europe , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Prosthesis Design , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 94(3): 342-347, 2019 09 01.
Article in English | MEDLINE | ID: mdl-30565371

ABSTRACT

BACKGROUND: The bio-engineered COMBO stent (OrbusNeich Medical BV, The Netherlands) is a dual-therapy pro-healing stent. This novel technology may allow a shorter duration of dual antiplatelet therapy (DAPT) after stenting. We present the first 3 year clinical outcomes of patients treated with COMBO stent. METHODS AND RESULTS: The prospective, multicenter, investigator-initiated, all-comers REMEDEE Registry evaluates clinical outcomes after COMBO stent treatment. A 1,000 patients were enrolled between June 2013 and March 2014. Patients had a mean of 65 years ±11, 26% of the patients were females and 18% diabetics. More than 50% of patients presented with acute coronary syndrome, 60% of treated lesions were AHA/ACC lesion type B2 or C. Target lesion failure (TLF) at 3 year follow-up occurred in 10.7% of patients (N = 105). The separate components cardiac death, target vessel myocardial infarction and target lesion revascularization occurred in 4.1%, 2.0%, and 7.1%, respectively of patients. Definite stent thrombosis (ST) was observed in 0.7% of all patients. At 3-year follow-up there were only 73 patients taking DAPT. CONCLUSIONS: At 3-year follow-up, patients treated with COMBO stent in the present large prospective all-comers cohort, continue to show good clinical outcomes. Clinicaltrials.gov identifier: NCT01874002. CONDENSED ABSTRACT: The COMBO stent is a sirolimus-eluting stent with a luminal anti-CD34-antibody layer, that binds endothelial progenitor cells. These cells can differentiate to endothelial cells and stimulate early endothelialization of the stent. The REMEDEE Registry is the first large, multicenter, prospective, cohort study evaluating the clinical outcomes of 1,000 all-comers patients treated with COMBO stent. Target lesion failure at 3 year follow-up was 10.7% and the rate of definite ST was 0.7%.


Subject(s)
Acute Coronary Syndrome/therapy , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention/instrumentation , Stents , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/mortality , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Europe , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prospective Studies , Registries , Risk Factors , Time Factors , Treatment Outcome
7.
Lancet ; 392(10153): 1117-1126, 2018 09 29.
Article in English | MEDLINE | ID: mdl-30190206

ABSTRACT

BACKGROUND: The FIREHAWK is a drug-eluting stent with a fully biodegradable sirolimus-containing polymer coating localised to recessed abluminal grooves on the stent surface. We investigated clinical outcomes with this targeted, low-dose, biodegradable polymer, sirolimus-eluting stent compared with XIENCE durable polymer, everolimus-eluting stents in an all-comers population. METHODS: The TARGET All Comers study was a prospective, multicentre, open-label randomised non-inferiority trial done at 21 centres in ten European countries. Patients with symptomatic or asymptomatic coronary artery disease and objective evidence of myocardial ischaemia who qualified for percutaneous coronary intervention were randomised 1:1 to undergo implantation of a FIREHAWK or XIENCE. Randomisation was web-based, with random block allocation and stratification by centre and ST elevation myocardial infarction. Outcome assessors were masked to treatment allocation, but treating physicians and patients were not. The primary endpoint was target lesion failure at 12 months, a composite of cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation. The control event rate for XIENCE was assumed to be 7%, the non-inferiority margin was 3.5%, and the primary analysis was in the intention-to-treat population, censoring patients who did not have either an event before 365 days or contact beyond 365 days. Late lumen loss was the primary endpoint of an angiographic substudy designed to investigate the non-inferiority of the FIREHAWK compared with the XIENCE stent. This trial is registered with ClinicalTrials.gov, number NCT02520180. FINDINGS: From Dec 17, 2015, to Oct 14, 2016, 1653 patients were randomly assigned to implantation of the FIREHAWK (n=823) or XIENCE (n=830). 65 patients in the FIREHAWK group and 66 in the XIENCE group had insufficient follow-up data and were excluded from the analyses. At 12 months, target lesion failure occurred in 46 (6·1%) of 758 patients in the FIREHAWK group and in 45 (5·9%) of 764 patients in the XIENCE group (difference 0·2%, 90% CI -1·9 to 2·2, pnon-inferiority=0·004, 95% CI -2·2 to 2·6, psuperiority=0·88). There were no differences in ischaemia-driven revascularisation or stent thrombosis rates at 12 months. 176 patients were included in the angiographic substudy, in which in-stent late lumen loss was 0·17 mm (SD 0·48) in the FIREHAWK group and 0·11 mm (0·52) in the XIENCE group (p=0·48), with an absolute difference of 0·05 mm (95% CI -0·09 to 0·18, pnon-inferiority=0·024). INTERPRETATION: In a broad all-comers population of patients requiring stent implantation for myocardial ischaemia, the FIREHAWK was non-inferior to the XIENCE as assessed with the primary endpoint of target lesion failure at 12 months and in-stent late lumen loss at 13 months. The FIREHAWK is a safe and effective alternative stent to treat patients with ischaemic coronary artery disease in clinical practice. FUNDING: Shanghai Microport Medical.


Subject(s)
Absorbable Implants , Drug-Eluting Stents , Immunosuppressive Agents/administration & dosage , Myocardial Ischemia/surgery , Sirolimus/administration & dosage , Aged , Equivalence Trials as Topic , Everolimus/administration & dosage , Female , Humans , Intention to Treat Analysis , Male , Middle Aged , Prospective Studies , Prosthesis Design , Treatment Outcome
8.
Open Heart ; 4(2): e000634, 2017.
Article in English | MEDLINE | ID: mdl-28761685

ABSTRACT

OBJECTIVE: The dual-therapy stent combines an abluminal biodegradable drug-eluting coating, with a 'pro-healing' luminal layer. This bioengineered layer attracts circulating endothelial progenitor cells that can differentiate into normal endothelium. Rapid endothelialisation of the stent might allow safe short dual antiplatelet therapy. We aim to assess clinical outcomes in patients treated with this novel device at 2-year follow-up. METHODS: A total of 1000 patients were included in the REMEDEE Registry to evaluate clinical outcomes after treatment with the dual-therapy stent. This prospective, multicentre, European registry included all-comers patients, which resulted in a high-risk patient population. Target lesion failure (TLF), a combined endpoint consisting of cardiac death, target vessel myocardial infarction (tv-MI) and target lesion revascularisation (TLR), at 2-year follow-up was the primary focus of this analysis. Subgroup analyses were performed according to diabetes mellitus (DM), gender, age, acute coronary syndrome, smoking, hypertension, hypercholesterolaemia, previous stroke, peripheral vascular disease and chronic renal failure. RESULTS: TLF at 2 years was observed in 84 patients (8.5%), with 3.0% cardiac death, 1.2% tv-MI and 5.9% TLR. Definite stent thrombosis at 2 years was 0.6%. In the presence of DM or chronic renal failure, a higher TLF was observed. CONCLUSIONS: The dual-therapy stent shows favourable clinical outcomes from 12 months onwards. Two years after stent placement, low TLF and very low stent thrombosis rates are observed in this large prospective all-comers cohort study. TRIAL REGISTRATION NUMBER: NCT01874002; Results.

9.
Catheter Cardiovasc Interv ; 90(2): E31-E37, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28145609

ABSTRACT

BACKGROUND: Patients presenting with acute coronary syndrome (ACS) are at increased risk of complications after percutaneous coronary intervention with stent placement compared to patients with stable angina (SA) treated in an elective setting. The novel pro-healing COMBO stent is a bio-engineered drug eluting stent designed to promote vessel healing. Therefore, the stent may reduce this difference in clinical outcomes between elective and ACS-patients and prevent late stent thrombosis. METHODS AND RESULTS: The European, prospective, multicenter, 1000 all-comers patient REMEDEE registry evaluates clinical outcomes after COMBO stent placement in ACS- and elective patients. The primary endpoint at 12 months is target lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target lesion revascularization. A total of 49.9% (n = 498) of patients presented with acute coronary syndrome. TLF was 7.1% in ACS patients, definite and probable stent thrombosis was observed in 0.5% of ACS patients and in all within 9 days post stenting. We found no significant difference in TLF between ACS and non-ACS patients and a low overall rate of TLF. CONCLUSIONS: The COMBO stent is a safe and efficient device for patients presenting with ACS. Low ST rate and only early stent thrombosis were observed. © 2017 Wiley Periodicals, Inc.


Subject(s)
Acute Coronary Syndrome/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/mortality , Aged , Coronary Thrombosis/etiology , Coronary Thrombosis/prevention & control , Drug Therapy, Combination , Europe , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/prevention & control , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Platelet Aggregation Inhibitors/administration & dosage , Prospective Studies , Prosthesis Design , Registries , Risk Factors , Time Factors , Treatment Outcome
10.
Int J Cardiol ; 226: 60-64, 2017 Jan 01.
Article in English | MEDLINE | ID: mdl-27788391

ABSTRACT

BACKGROUND: The COMBO stent is a novel sirolimus-eluting stent with a luminal anti-CD34+ antibody layer to promote vessel healing. No data is currently available on clinical outcomes after treatment with this novel bio-engineered device in diabetic patients. We evaluate clinical outcomes at twelve months after COMBO stent placement in patients without diabetes mellitus (non-DM), patients with non-insulin-treated diabetes mellitus (nITDM) and patients with insulin-treated diabetes mellitus (ITDM). METHODS: This study is a pre-specified subgroup analysis of the 1000 patient all-comers REMEDEE Registry. The primary endpoint is target lesion failure (TLF), which is a combined endpoint consisting of cardiac death, target vessel-myocardial infarction (tv-MI) and target lesion revascularization (TLR) at twelve months follow-up. Kaplan Meier method is used with log rank to compare outcomes between groups. RESULTS: This subgroup analysis includes 807 non-DM, 117 nITDM and 67 ITDM. Kaplan-Meier estimates for TLF at twelve months are 4.4% in non-DM, 6.8% in nITDM and 20.3% in ITDM, p<0.001 (non-DM vs nITDM p=0.244, non-DM vs ITDM p<0.001). CONCLUSIONS: This study gives the first insight into the impact of insulin-treated diabetes mellitus on clinical outcome of patients treated with the novel COMBO stent. At one year after COMBO stent placement significantly higher rates of target lesion failure are seen in patients with ITDM compared to patients with nITDM and patients without DM.


Subject(s)
Diabetes Mellitus, Type 1/mortality , Diabetes Mellitus, Type 1/therapy , Diabetes Mellitus, Type 2/mortality , Diabetes Mellitus, Type 2/therapy , Drug-Eluting Stents/trends , Insulin/administration & dosage , Aged , Bioengineering/trends , Diabetes Mellitus, Type 1/diagnosis , Diabetes Mellitus, Type 2/diagnosis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/mortality , Percutaneous Coronary Intervention/trends , Prospective Studies , Registries , Treatment Outcome
11.
JACC Cardiovasc Interv ; 9(11): 1127-34, 2016 06 13.
Article in English | MEDLINE | ID: mdl-27209254

ABSTRACT

OBJECTIVES: This registry evaluated the safety and clinical outcomes of the Combo stent in an all-comers population in routine clinical practice. We report 1-year results. BACKGROUND: Limitations of current generation drug-eluting stents (DES) are 3-fold: stent thrombosis, neoatherosclerosis related to impaired healing, and repeat revascularization due to (late-) in-stent restenosis. The Combo stent combines an abluminal biodegradable coating eluting sirolimus and a luminal anti-CD34(+) antibody layer to attract endothelial progenitor cells in order to promote vessel healing, thus preventing neointima formation and restenosis. METHODS: The REMEDEE (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coatED bio-Engineered StEnt) post-market registry was an international, multicenter, prospective trial that evaluated clinical outcomes after deployment of the Combo stent, in an all-comers population of patients treated with a Combo stent in the setting of routine clinical care. Clinical endpoints were target lesion failure (TLF), defined as a composite of cardiac death, nonfatal myocardial infarction (MI), or target lesion revascularization (TLR). RESULTS: Between June 2013 and March 2014, a total of 1,000 patients were included in the registry, 49.9% of whom presented with acute coronary syndrome. Mean age was 65 ± 11 years old (range: 34 to 94 years of age), and 74% of patients were male; 58.9% of 1,255 lesions were American Heart Association type B2 or C lesions. The primary endpoints were 5.7% TLF, 1.7% cardiac death, 0.7% target vessel MI, and 4.4% TLR. Definite stent thrombosis occurred in 0.5% of subjects; no thrombosis occurred after 9 days post-stenting. CONCLUSIONS: This registry showed excellent 1-year results of novel Combo bioengineered stent technology in an all-comers patient population. (Prospective Registry to Assess the Long-term Safety and Performance of the Combo Stent [REMEDEE]; NCT01874002).


Subject(s)
Acute Coronary Syndrome/therapy , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Sirolimus/administration & dosage , Acute Coronary Syndrome/diagnostic imaging , Adult , Aged , Aged, 80 and over , Cardiovascular Agents/adverse effects , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/prevention & control , Coronary Thrombosis/etiology , Coronary Thrombosis/prevention & control , Europe , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/prevention & control , Neointima , Percutaneous Coronary Intervention/adverse effects , Product Surveillance, Postmarketing , Prospective Studies , Prosthesis Design , Registries , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome , Wound Healing
SELECTION OF CITATIONS