Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
2.
Ann Surg Treat Res ; 95(3): 129-134, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30182018

ABSTRACT

PURPOSE: PEAK PlasmaBlade is a recent and distinctive type of electrosurgical device. Previous studies have already documented some meaningful advantages of this device over conventional electrosurgery. This study compared the use of PEAK PlasmaBlade to standard electrosurgery in mastectomy and breast conservative surgery. The purpose was to test the impact of PEAK PlasmaBlade on the wound-healing process and on postsurgical complications in breast cancer surgery. METHODS: Sixty patients undergoing breast cancer surgery were enrolled. The PEAK PlasmaBlade was used for 20 of those. A standard electrosurgical device was used for the other 40 patients. The 2 groups were homogenous in age, body mass index, comorbidities and type of surgery. We recorded wound complications, serum drainage amount and duration of stay, blood loss, time of surgery, length of hospital stay, and total number of medications required. RESULTS: The 2 groups were not significantly different in terms of patient characteristics. A statistically significant reduction in incidence of seroma was observed in the PEAK group: only 10% versus 37.5% of the patients in the conventional electrosurgery group developed this complication (Fisher exact test, P = 0.034). CONCLUSION: Seroma is the most important wound complication in breast surgery. The research of new instruments that might reduce its incidence is desirable. In order to validate or deny the results of this study, it is necessary to enroll more subjects and to consider the impact of this device on axillary lymph node dissection.

3.
Gland Surg ; 7(2): 234-238, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29770317

ABSTRACT

An incomplete regression of the mammary line during embryogenesis occurs in 0.2-6% of the population, which may result in the presence of ectopic breast tissue (EBT). The development of a carcinoma in the EBT is a rare event. The authors present a case report of a 76-year-old female patient, with a lobular carcinoma in an abdominal wall EBT submitted to surgery and adjuvant chemotherapy.

4.
Gland Surg ; 6(5): 525-529, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29142844

ABSTRACT

Use of antibiotic prophylactic (AP) in clean surgery is still controversial. We reviewed the literature of the last 10 years to identify the best way to approach the use of prophylactic antibiotic in thyroid surgery. In thyroid surgery, it is a highly controversial topic primarily due to the lack of evidence in "support" of or "against" antibiotic use. In this review, the authors analyze the literature on the use of AP in thyroid surgery in order to evaluate if the available data support or contradict this use routinely.

5.
Eur Radiol ; 26(2): 381-9, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26045345

ABSTRACT

PURPOSE: To compare the diagnostic performance of cone-beam CT (CBCT)-guided and CT fluoroscopy (fluoro-CT)-guided technique for transthoracic needle biopsy (TNB) of lung nodules. METHODS: The hospital records of 319 consecutive patients undergoing 324 TNBs of lung nodules in a single radiology unit in 2009-2013 were retrospectively evaluated. The newly introduced CBCT technology was used to biopsy 123 nodules; 201 nodules were biopsied by conventional fluoro-CT-guided technique. We assessed the performance of the two biopsy systems for diagnosis of malignancy and the radiation exposure. RESULTS: Nodules biopsied by CBCT-guided and by fluoro-CT-guided technique had similar characteristics: size, 20 ± 6.5 mm (mean ± standard deviation) vs. 20 ± 6.8 mm (p = 0.845); depth from pleura, 15 ± 15 mm vs. 15 ± 16 mm (p = 0.595); malignant, 60% vs. 66% (p = 0.378). After a learning period, the newly introduced CBCT-guided biopsy system and the conventional fluoro-CT-guided system showed similar sensitivity (95% and 92%), specificity (100% and 100%), accuracy for diagnosis of malignancy (96% and 94%), and delivered non-significantly different median effective doses [11.1 mSv (95 % CI 8.9-16.0) vs. 14.5 mSv (95% CI 9.5-18.1); p = 0.330]. CONCLUSION: The CBCT-guided and fluoro-CT-guided systems for lung nodule biopsy are similar in terms of diagnostic performance and effective dose, and may be alternatively used to optimize the available technological resources. KEY POINTS: • CBCT-guided and fluoro-CT-guided lung nodule biopsy provided high and similar diagnostic accuracy. • Effective dose from CBCT-guided and fluoro-CT-guided lung nodule biopsy was similar. • To optimize resources, CBCT-guided lung nodule biopsy may be an alternative to fluoro-CT-guided.


Subject(s)
Lung Neoplasms/diagnostic imaging , Adult , Aged , Biopsy, Needle/methods , Cone-Beam Computed Tomography/methods , Female , Fluoroscopy/methods , Humans , Image-Guided Biopsy/methods , Lung Neoplasms/pathology , Male , Middle Aged , Radiation Dosage , Radiography, Interventional/methods , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
6.
Int J Surg ; 11 Suppl 1: S73-8, 2013.
Article in English | MEDLINE | ID: mdl-24380559

ABSTRACT

BACKGROUND AND PURPOSE OF THE STUDY: Axillary lymph node status at the time of diagnosis remains one of the most important prognostic factors in women with breast cancer. Sentinel lymph node biopsy (SLNB) proved to be a reliable method for the evaluation of axillary nodal status in early-stage invasive breast cancer. The prognostic value and potential therapeutic consequences of SLN micrometastases remains a matter of great debate. PATIENTS AND METHODS: From January 1998 to March 2011, 1,976 consecutive patients with non-metastatic invasive breast cancer underwent surgical treatment; 1,080 of them (54.6%) underwent SLNB. We collected data regarding demography, preoperative lymphoscintigraphy, type of surgery, histopathologic and immunohistochemical features and adjuvant treatment. MAIN FINDINGS: A mean number of 2.1 ± 1.4 (range 1-13) SLN per patient were collected, a total of 2,294 nodes. SLNs were macrometastatic in 16.7% of patients and micrometastatic in 3.3%. Among the patients with positive SLN 93.6% underwent complete ALND. The overall survival (OS) and disease-free survival (DFS) of 72 patients with micrometastases in SLN at 60 months was 100%, similar to patients with negative SLN (98.7%), quite different from the DFS of N1-N3 patients (85.8%). Statistically significant differences in OS and DFS were observed between patients with N1mi and the group with N1-N3 sentinel node (p < 0.001 and p = 0.04) and also between patients with negative SLN and those with macrometastatic SLN (p < 0.001 for both). CONCLUSION: SLN micrometastases could represents an epiphenomenon of peritumoral lymphovascular invasion which impacts independently on the survival of patients with invasive breast cancer.


Subject(s)
Breast Neoplasms/diagnosis , Breast Neoplasms/pathology , Aged , Analysis of Variance , Disease-Free Survival , Female , Humans , Kaplan-Meier Estimate , Lymphatic Metastasis , Middle Aged , Neoplasm Micrometastasis , Prognosis , Sentinel Lymph Node Biopsy
7.
Am J Obstet Gynecol ; 204(4): 338.e1-7, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21272849

ABSTRACT

OBJECTIVE: The purpose of this study was to determine whether the maximum time for cervical ripening (from 24-12 hours) would influence the efficacy of a transcervical Foley catheter and to compare efficacy to that of a prostaglandin E(2) vaginal insert. STUDY DESIGN: Three hundred ninety-seven women were assigned randomly to (1) Foley catheter left in place for a maximum of 24 hours, (2) Foley catheter left in place for a maximum of 12 hours, or (3) prostaglandin E(2) controlled-release vaginal insert. Primary outcome was vaginal delivery within 24 hours. RESULTS: There were no differences in vaginal delivery rates. The proportion of women who achieved vaginal delivery in 24 hours was lower in the 24-hour Foley catheter group than in the other 2 groups (24-hour Foley catheter, 21.0%; 12-hour Foley catheter, 59.8%; vaginal prostaglandin E(2), 48.5%; P < .0001). CONCLUSION: Cutting the ripening time with a Foley catheter by one-half increases the proportion of women who deliver vaginally within 24 hours and yields efficacy similar to that of prostaglandin E(2) vaginal insert.


Subject(s)
Catheterization , Catheters , Cervical Ripening , Dinoprostone/therapeutic use , Oxytocics/therapeutic use , Administration, Intravaginal , Adult , Delivery, Obstetric , Female , Humans , Labor, Induced , Pregnancy , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...