Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 97: 118-23, 2012 Aug 15.
Article in English | MEDLINE | ID: mdl-22841055

ABSTRACT

A new process to pretreat blood samples has been developed. This process combines the Advanced Oxidation Process (AOP) treatment (using H(2)O(2) and UV irradiation) with acid deactivation of the enzyme catalase in blood. A four-cell reactor has been designed and built in house. The effect of pH on the AOP process has been investigated. The kinetics of the pretreatment process shows that at high C(H(2)O(2),t=0), the reaction is zeroth order with respect to C(H(2)O(2)) and first order with respect to C(blood). The rate limiting process is photon flux from the UV lamp. Degradation of whole blood has been compared with that of pure hemoglobin samples. The AOP pretreatment of the blood samples has led to the subsequent determination of chromium and zinc concentrations in the samples using electrochemical methods.


Subject(s)
Blood Chemical Analysis/methods , Blood/drug effects , Blood/radiation effects , Hydrogen Peroxide/pharmacology , Ultraviolet Rays , Animals , Chromium/blood , Chromium/chemistry , Electrochemistry , Hydrogen-Ion Concentration , Oxidation-Reduction/drug effects , Oxidation-Reduction/radiation effects , Zinc/blood , Zinc/chemistry
2.
Talanta ; 82(2): 675-80, 2010 Jul 15.
Article in English | MEDLINE | ID: mdl-20602953

ABSTRACT

A bismuth bulk electrode (BiBE) has been investigated as an alternative electrode for the anodic stripping voltammetric (ASV) analysis of Pb(II), Cd(II), and Zn(II). The BiBE, which is fabricated in-house, shows results comparable to those of similar analyses at other Bi-based electrodes. Metal accumulation is achieved by holding the electrode potential at -1.4V (vs. Ag/AgCl) for 180 s followed by a square wave voltammetric stripping scan from -1.4 to -0.35 V. Calibration plots are obtained for all three metals, individually and simultaneously, in the 10-100 microg L(-1) range, with a detection limit of 93, 54, and 396 ng L(-1) for Pb(II), Cd(II), Zn(II), respectively. A slight reduction in slope is observed for Cd(II) and Pb(II) when the three metals are calibrated simultaneously vs. individually. Comparing the sensitivities of the metals when calibrated individually vs. in a mixture reveals that Zn(II) is not affected by stripping in a mixture. However, Pb(II) and Cd(II) have decreasing sensitivities in a mixture. The optimized method has been successfully used to test contaminated river water by standard addition. The results demonstrate the ability of the BiBE as an alternative electrode material in heavy metal analysis.


Subject(s)
Bismuth/chemistry , Cadmium/analysis , Lead/analysis , Zinc/analysis , Electrochemistry/methods , Electrodes , Limit of Detection , Potentiometry , Spectrophotometry/methods
3.
Anal Chem ; 78(21): 7582-7, 2006 Nov 01.
Article in English | MEDLINE | ID: mdl-17073430

ABSTRACT

A new method for pretreating blood samples for trace Cr analysis is described. The advanced oxidation process (AOP with H2O2 and 5.5-W UV irradiation for 60 min) is used to remove biological/organic species for subsequent analysis. Prior to the AOP pretreatment, acid (HNO3) is used at pH 3.0 to inhibit the enzyme catalase in the blood samples. Catalytic adsorptive stripping voltammetry at a bismuth film electrode gives a Cr concentration of 6.0 +/- 0.3 ppb in the blood samples. This concentration was confirmed by dry-ashing the blood samples and subsequent analysis by atomic absorption spectroscopy. This current method may be used to monitor chromium, a trace metal in humans, and the efficacy and safety of chromium supplements as adjuvant therapy for diabetes.


Subject(s)
Chromium/blood , Electrochemistry/methods , Adsorption , Calibration , Catalysis , Hydrogen Peroxide , Oxidation-Reduction
SELECTION OF CITATIONS
SEARCH DETAIL
...