Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Asian J Neurosurg ; 18(2): 301-305, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37397042

ABSTRACT

Background The choice of intraoperative fluid in neurosurgical patients is important as we need to maintain adequate cerebral perfusion and oxygenation and also avoid cerebral edema. Normal saline (NS) is commonly used in neurosurgeries, but it leads to hyperchloremic metabolic acidosis, which may result in coagulopathy. Balanced crystalloid with physiochemical composition akin to that of plasma has favorable effects on metabolic profile and may avoid the problems associated with NS. Against this background, the present study aimed to compare the effects of NS versus PlasmaLyte (PL) on coagulation profile in patients undergoing neurosurgical procedures. Methods This prospective, randomized, double-blinded study was conducted in 100 adult patients scheduled to undergo various neurosurgical procedures. Patients were randomly allocated in two groups of 50 each to receive either NS or PL intraoperatively and postoperatively till 4 hours after the surgery. Hemoglobin, hematocrit, coagulation profile (PT, PTT, and INR), serum chloride, pH, blood urea, and serum creatinine were measured prior to induction (baseline) and 4 hours after completion of surgery. Results Demographic characteristics were statistically similar between the two groups. Coagulation profile parameters were comparable between the two groups at baseline as well as 4 hours after surgery. pH was significantly lower in the NS group as compared to the PL group at 4 hours after surgery. Postoperatively blood urea, serum creatinine, and serum chloride levels were significantly raised in the NS group as compared to the PL group. Hemoglobin and hematocrit values were similar between the two groups. Conclusion Coagulation profile parameters were normal and statistically similar with intraoperative infusion of NS versus PL in patients undergoing neurosurgical procedures. However, use of PL was associated with a better acid-base and renal profile in these patients.

2.
Asian J Neurosurg ; 17(3): 463-469, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36398172

ABSTRACT

Objective Skull pin insertion in patients undergoing craniotomies elicits hemodynamic and neuroendocrine stress response that may be deleterious to the patient. Various drugs and techniques have been documented in literature to abate this stress response. Against this background, we aimed to compare the efficacy of intravenous dexmedetomidine and local infiltration of ropivacaine for attenuation of stress response to pin insertion in craniotomies. Methods Eighty-eight adult patients undergoing craniotomy under general anesthesia from March 2019 to April 2020 requiring application of head holder were randomized into two equal groups. After intubation, 0.75 µg kg -1 of dexmedetomidine over 10 minutes through infusion was given in group D, while local infiltration at pin sites was done with 0.5% ropivacaine, 2 mL at each site in group R. Hemodynamic parameters and levels of serum cortisol, prolactin, and blood glucose were measured before and after pin insertion. Unpaired t -test for continuous variables and Mann-Whitney U test was used for nonnormally distributed variables. Results Heart rate was statistically similar between the two groups at all the observed time points. The difference in mean arterial pressure values between the two groups was found to be statistically significant only from 10 to 20 minutes after pin insertion being statistically similar at rest of the time points. Levels of serum glucose, cortisol, and prolactin values 30 minutes after pin insertion were statistically similar between both groups. Conclusion We concluded that both interventions are equally efficacious in attenuation of hemodynamic and stress response to head holder application in patients undergoing craniotomies.

3.
Cureus ; 14(12): e32337, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36628012

ABSTRACT

BACKGROUND: The study objective involves the evaluation of preoperative audiovisual information on the operation theater environment as a tool to relieve anxiety in patients posted for infra umbilical elective surgery under spinal anesthesia. Perioperative anxiety is detrimental to both intraoperative hemodynamic instability and postoperative recovery. MATERIAL AND METHODS:  The design was a single-center, prospective, randomized control trial. There were 120 patients in this study within the 18-60-year-old age range who were American Society of Anaesthesiologists (ASA) class I-II admitted for infra-umbilical surgery excluding lower segment cesarean section (LSCS) under spinal anesthesia. Patients were randomized into two groups: those who were not exposed to an audiovisual tour (NA) (n = 60) and those who were exposed to an audiovisual tour (A) (n = 60). The measurements are based on the demographic details of the patient; the visual analogue score (VAS); and the Amsterdam Preoperative Anxiety and Information Scale (APAIS) for anxiety, hemodynamic parameters i.e., blood pressure (BP), heart rate (HR), respiratory rate (RR), and patient satisfaction score (PSS) on a five-point Likert scale were noted perioperatively for both the groups. RESULTS:  The main results showed a significant (p-value <0.05) decrease in VAS and APAIS for anxiety, HR, and PSS. This was observed during the intraoperative and postoperative periods in the A group in comparison to the NA group. CONCLUSION: The preoperative audiovisual virtual tour of the operation theater effectively reduces perioperative anxiety and stabilizes HR; it also improves the satisfaction of patients undergoing elective surgery under spinal anesthesia.

4.
Acta Obstet Gynecol Scand ; 99(8): 1031-1038, 2020 08.
Article in English | MEDLINE | ID: mdl-31643082

ABSTRACT

INTRODUCTION: It is hypothesized that increased intraabdominal pressure (IAP) may be a cause of preeclampsia. There is, however, a paucity of clinical data regarding IAP in preeclamptics. We evaluated and compared the IAP and its effects on organ functions, in normotensive and preeclamptic patients. MATERIAL AND METHODS: Previously healthy non-laboring patients with a singleton pregnancy scheduled for elective cesarean section under subarachnoid block were enrolled (preeclamptic and normotensive; n = 29 each). IAP was measured using an indwelling Foley catheter, and compared in both cohorts at four predefined time points: just before subarachnoid block, immediately after the onset of sensory block to T6 dermatomal level, just after surgery, and 2 hours later. In addition, the presence of organ dysfunction for respiratory, cardiovascular, renal, hepatic, hematopoietic and central nervous systems were evaluated for association with IAP. RESULTS: Although age, body mass index, gravidity, parity, serum bilirubin, serum creatinine, PaO2 /FiO2 ratio and Glasgow coma score of the preeclamptic and normotensive patients were similar, the mean blood pressure was significantly higher (P < 0.001), the period of gestation less (P = 0.003) and the platelet count lower (P = 0.020) in the former. The IAP was significantly higher in the preeclamptic group at all four time points: respectively, 15.1 (1.0) vs 14.2 (0.9) mm Hg (P = 0.002); 14.9 (0.9) vs 14.1 (1.0) mm Hg (P = 0.002), 10.4 (1.0) vs 9.5 (1.3) mm Hg (P = 0.008) and 10.2 (0.8) vs 9.2 (1.2) mm Hg (P = 0.001). There was no correlation between the IAP and various organ dysfunctions. CONCLUSIONS: Preeclampsia is associated with a significantly higher IAP in patients undergoing a cesarean section. The clinical relevance of this finding needs further investigation.


Subject(s)
Abdomen/physiopathology , Cesarean Section , Pre-Eclampsia/physiopathology , Adult , Female , Humans , Pregnancy , Pregnancy Outcome , Prospective Studies , Risk Factors
5.
J Anaesthesiol Clin Pharmacol ; 35(4): 460-467, 2019.
Article in English | MEDLINE | ID: mdl-31920228

ABSTRACT

BACKGROUND AND AIMS: Ventilation can induce increase in inflammatory mediators that may contribute to systemic organ dysfunction. Ventilation-induced organ dysfunction is likely to be accentuated if there is a pre-existing systemic inflammatory response. MATERIAL AND METHODS: Adult patients suffering from intestinal perforation peritonitis-induced systemic inflammatory response syndrome and scheduled for emergency laparotomy were randomized to receive intraoperative ventilation with 10 ml.kg-1 tidal volume (Group H) versus lower tidal volume of 6 ml.kg-1 along with positive end-expiratory pressure (PEEP) of 10 cmH2O (Group L), (n = 45 each). The primary outcome was postoperative organ dysfunction evaluated using the aggregate Sepsis-related Organ Failure Assessment (SOFA) score. The secondary outcomes were, inflammatory mediators viz. interleukin-6, tumor necrosis factor-α, procalcitonin, and C-reactive protein, assessed prior to (basal) and 1 h after initiation of mechanical ventilation, and 18 h postoperatively. RESULTS: The aggregate SOFA score (3[1-3] vs. 1[1-3]); and that on the first postoperative day (2[1-3] vs. 1[0-3]) were higher for group L as compared to group H (P < 0.05). All inflammatory mediators were statistically similar between both groups at all time intervals (P > 0.05). CONCLUSIONS: Mechanical ventilation with low tidal volume of 6 ml/kg-1 along with PEEP of 10 cmH2O is associated with significantly worse postoperative organ functions as compared to high tidal volume of 10 ml.kg-1 in patients of perforation peritonitis-induced systemic inflammation undergoing emergency laparotomy.

7.
J Anaesthesiol Clin Pharmacol ; 33(1): 57-63, 2017.
Article in English | MEDLINE | ID: mdl-28413273

ABSTRACT

BACKGROUND AND AIMS: Benefits of intraoperative low tidal volume ventilation during laparoscopic surgery are not conclusively proven, even though its advantages were seen in other situations with intraoperative respiratory compromise such as one-lung ventilation. The present study compared the efficacy of intraoperative low tidal volume ventilatory strategy (6 ml/kg along with positive end-expiratory pressure [PEEP] of 10 cmH2O) versus one with higher tidal volume (10 ml/kg with no PEEP) on various clinical parameters and plasma levels of interleukin (IL)-6 in patients undergoing laparoscopic cholecystectomy. MATERIAL AND METHODS: A total of 58 adult patients with American Society of Anesthesiologists physical status I or II, undergoing laparoscopic cholecystectomy were randomized to receive the low or higher tidal volume strategy as above (n = 29 each). The primary outcome measure was postoperative PaO2. Systemic levels of IL-6 along with clinical indices of intraoperative gas exchange, pulmonary mechanics, and hemodynamic consequences were measured as secondary outcome measures. RESULTS: There was no statistically significant difference in oxygenation; intraoperative dynamic compliance, peak airway pressures, or hemodynamic parameters, or the IL-6 levels between the two groups (P > 0.05). Low tidal volume strategy was associated with significantly higher mean airway pressure, lower airway resistance, greater respiratory rates, and albeit clinically similar, higher PaCO2and lower pH (P < 0.05). CONCLUSION: Strategy using 6 ml/kg tidal volume along with 10 cmH2O of PEEP was not associated with any significant improvement in gas exchange, hemodynamic parameters, or systemic inflammatory response over ventilation with 10 ml/kg volume without PEEP during laparoscopic cholecystectomy.

SELECTION OF CITATIONS
SEARCH DETAIL
...