Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Neoplasma ; 64(6): 954-961, 2017.
Article in English | MEDLINE | ID: mdl-28895416

ABSTRACT

Current guidelines for follow-up after resection of colorectal cancer (CRC) recommend regular measurements of carcinoembryogenic antigen (CEA) and imaging tests. Multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) are currently primary imaging modalities, while the role of fluorine-18-fluoro-deoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), which is recommended in patients with negative MDCT and increased CEA, is still uncertain. Our aim was to compare diagnostic performance and prognostic significance of 18F-FDG PET/CT with MRI and tumor markers CEA and carbohydrate antigen 19-9 (CA 19-9) in detection of recurrent CRC. This prospective study included 35 patients with resected CRC, referred to 18F-FDG PET/CT examination for suspected recurrence. During median follow-up of 24.4±1.5 months 18F-FDG PET/CT and MRI results and tumor marker levels were compared with findings of histopathological examination or with results of clinical and imaging follow-up. Management plan before the 18F-FDG PET/CT scan was considered and compared to the final treatment decision. The sensitivity, specificity, positive and negative predictive value and accuracy of 18F-FDG PET/CT and MRI in detection of recurrent colorectal cancer in patient-based analysis were 92.6%, 75%, 92.6%, 75% and 88.6%, and 65.4%, 66.7%, 85%, 40% and 65.7%, respectively. In lesion-based analysis the sensitivity of 18F-FDG PET/CT and MRI was 83.1% and 68.2%, respectively. The overall accuracy of CEA and CA 19-9 in recurrence detection was 48.6% and 54.3%, respectively. PET/CT induced therapy alterations in 13/35 (37.1%) patients. Progression was observed in 16/35 patients during follow-up, with significantly lower risk of progression in patients with treatment changes based on PET findings (Multivariate Cox regression; p=0.017). In addition, elevated CA 19-9 levels in time of PET scan and male gender carried significantly higher risk of progression (p=0.007 and p=0.016, respectively). Kaplan-Meier Log rank test showed significantly longer progression-free survival time in patients who had treatment plan changed based on PET/CT (p=0.046). We can conclude that 18F-FDG PET/CT showed better sensitivity and accuracy compared to MRI in detection of recurrent colorectal cancer, with much better sensitivity compared to CEA and CA 19-9. Patients with treatment changes based on 18F-FDG PET/CT had significantly better prognosis and longer progression-free survival, while elevated values of CA 19-9 and male gender were associated with worse prognosis.


Subject(s)
Colorectal Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Positron Emission Tomography Computed Tomography , Biomarkers, Tumor/analysis , CA-19-9 Antigen/analysis , Carcinoembryonic Antigen/analysis , Female , Fluorodeoxyglucose F18 , Humans , Male , Neoplasm Recurrence, Local , Prognosis , Prospective Studies , Radiopharmaceuticals , Sensitivity and Specificity
2.
Neoplasma ; 63(2): 313-21, 2016.
Article in English | MEDLINE | ID: mdl-26774154

ABSTRACT

Higher intensity of FDG uptake on PET/CT in primary tumor is seen in patients with IDC compared to ILC, also in high grade tumours, tumours with negative ER and higher Ki67 values, while data are inconsistent in case of relation between primary tumor's PgR and HER2 expression with its metabolic activity levels. On account of the lack of studies that include research of breast cancer metastatic lesion metabolism level and its relation to tumor histology and biology, our goal was to investigate the association of metastatic lesions' glucose metabolism level on PET/CT with different histological and biological characteristics of primary tumor. In a total number of N=100 patients, highest SUVmax values for each patient were used in testing difference between metastatic metabolic activity in patients with different tumor histology, grade, ER, PgR and HER2 status, subtype, as well in testing relation of Ki67 index to metastasis' metabolism level. In testing difference between histological types of breast cancer, SUVmax values were also compared separately for each specific anatomical site (regional and distant lymph nodes, bones and liver). No difference was found regarding metastatic SUVmax values in patients with primary IDC (n=55, median SUVmax 9.70) and ILC (n=34, median SUVmax 7.20) independently of anatomic site, and for each of analysed sites separately. No difference was found as well between SUVmax detected in metastasis in patients with different grade (grade II: n=58, median SUVmax 7.70; grade III: n=12, median SUVmax 10.20), ER (59 positive, median SUVmax 8.50; 22 negative, median SUVmax 8.05), PgR (55 positive, median SUVmax 8.50; 23 negative, median SUVmax 7.80), and HER2 (14 positive, median SUVmax 6.84; 51 negative, median SUVmax 8.63) expression in primary tumor, and between patients with different tumor subtype. Ki67 was also not associated with tumor metastatic SUVmax values (n=11, rs = -0.21, p=0.53). We conclude that there is no association of primary breast cancer histological type, grade, ER, PgR, HER2 and Ki67 expression with metabolic activity in metastasis detected on PET/CT.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Energy Metabolism/physiology , Fluorodeoxyglucose F18/metabolism , Glucose/metabolism , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals/metabolism , Bone Neoplasms/metabolism , Bone Neoplasms/secondary , Female , Humans , Ki-67 Antigen/metabolism , Liver Neoplasms/metabolism , Liver Neoplasms/secondary , Lymph Nodes/metabolism , Lymphatic Metastasis/pathology , Male , Middle Aged , Multimodal Imaging , Receptor, ErbB-2/metabolism , Receptors, Estrogen/metabolism , Receptors, Progesterone/metabolism
3.
Neoplasma ; 62(3): 449-55, 2015.
Article in English | MEDLINE | ID: mdl-25866225

ABSTRACT

Neuroblastoma is the most common malignancy in children comprising 7.6% of all infantile cancers. MIBG scintigraphy is a mandatory neuroblastoma diagnostic test, which is among others methods, semi-quantified by the SIOPEN method. The aim of this study was to test both the skeletal and the soft tissue segments of the SIOPEN scoring method in the diagnostic milieu and to correlate them with the Curie score. Since there is little knowledge of their diagnostic power, the following variables were tested: VMA, HVA, LDH, and MYCN, ferritin, bone marrow infiltration, the INSS and the INPC classification. The cross-sectional study with repeated measurements of 143 scintigrams was performed on 76 pediatric patients with suspected or proven neuroblastoma, who had been referred to the Center for Nuclear Medicine of the Clinical Center of Serbia in the period 2007-2012. The range of the SIOPEN soft tissue scores was 0-5. The range of the SIOPEN skeletal scores was 0-57. The range of the Curie scores was 0-26. The skeletal SIOPEN scores were significantly higher in bone marrow positive children, in children with pathologically elevated urinary VMA levels and in children having a more advanced clinical stage. There was no difference in the SIOPEN soft tissue score due to higher VMA levels, or depending on the clinical stage and positive bone marrow assessment. There was no difference between the SIOPEN skeletal and soft tissue scores on one hand and the histological grade of the tumor; elevated or normal levels of HVA, LDH, NSE and ferritin, or the presence or absence of MYNC amplification in the neuroblastoma cell line, on the other hand. The results of both SIOPEN scores showed a high linear correlation with the Curie score. The conclusion is that the soft tissue segment of the SIOPEN score needs further elucidation in a more controlled milieu. Excellent correlation between all segments of the two semi-quantitative scoring methods speaks in favor of the application of the complete SIOPEN scoring system in every day mIBG scanning.

4.
Neoplasma ; 62(2): 295-301, 2015.
Article in English | MEDLINE | ID: mdl-25591595

ABSTRACT

UNLABELLED: Multi-detector computed tomography (MDCT) is most commonly used for staging of non-small cell lung cancer (NSCLC). In recent years, 18F- fluorodeoxyglucose positron emission tomography combined with computed tomography (18F-FDG PET/CT) has also been used for the same purpose. Since studies comparing these two methods are scarce, our aim was to determine how the TNM classification and thereby staging of NSCLC compare between 18F-FDG PET/CT and MDCT. 18F-FDG PET/CT and MDCT were collected in 83 patients with NSCLC 3 to 30 days apart (median 17 days). The investigators interpreting 18F-FDG PET/CT were unaware of MDCT results. The Cohen's kappa (κ) was calculated to determine the rate of agreement. The hypothesis was that the strength of agreement between the two methods will be at least moderate (κ>0.40) based on the adopted criteria (κ<0.20 poor; 0.21-0.40 fair; 0.41-0.60 moderate; 0.61-0.80 good; 0.81-1.00 very good agreement). The agreement was moderate for determining the T class (κ=0.45, overall agreement 58%), poor for the N class (κ=0.13, 42%) and fair for the M class (κ=0.22, 58%). The agreement for overall staging of NSCLC was poor (κ=0.20, 45%). The major source of disagreement was that metastases were present more frequently and/or in larger number on 18F-FDG PET/CT than MDCT in the contralateral mediastinal, supraclavicular, and distant lymph nodes, as well as in the bones and suprarenal glands. Since 18F-FDG PET/CT detected more regional and distant metastases than MDCT, we conclude that FDG PET/CT is useful for staging/restaging and planning treatment of patients with NSCLC. KEYWORDS: Non-small cell lung cancer, positron emission tomography, multidetector computed tomography, metastases detection.

5.
Eur J Radiol ; 84(3): 350-359, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25579474

ABSTRACT

PURPOSE: Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. METHODS: Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient (rS). RESULTS: Median SPV of the esophageal carcinoma (7.1; range: 2.8-13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4-2.4), (Z=-5.511, p<0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF (rS=0.484, p=0.002), BV (rS=0.637, p<0.001) and PS (rS=0.432, p=0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF (rS=0.573, p<0.001), BV (rS=0.849, p<0.001) and PS (rS=0.761, p<0.001). CONCLUSIONS: We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy tissue. The SPV was validated against quantitative CT perfusion measurements and statistically significant correlation was proved.


Subject(s)
Esophageal Neoplasms/diagnostic imaging , Multidetector Computed Tomography , Perfusion Imaging , Tomography, X-Ray Computed , Blood Volume , Esophageal Neoplasms/complications , Esophageal Neoplasms/pathology , Humans , Male , Perfusion , Perfusion Imaging/methods , Prospective Studies , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
6.
J BUON ; 17(3): 537-42, 2012.
Article in English | MEDLINE | ID: mdl-23033296

ABSTRACT

PURPOSE: To assess the value of whole body scintigraphy using (99m)Tc-HYNIC-TOC (Tektrotyd) and with single photon emission computerized tomography (SPECT) in the detection of primary and metastatic neuroendocrine tumors (NETs). METHODS: Thirty patients with different neuroendocrine tumors, mainly gastroenteropancreatic (GEP), were investigated. Whole body scintigraphy was performed 2 h (if necessary 10 min and 24h) after i.v. administration of 740 Mbq (99m)Tc-Tektrotyd, Polatom. In cases of unclear findings obtained by whole body scintigraphy, investigation was followed by SPECT. RESULTS: From 12 patients with NETs of unknown origin, there were 10 true positive (TP), and 2 false negative (FN) findings. Diagnosis was made with SPECT in 6 patients. From 8 patients with gut carcinoids, there were 4 TP, 2 true negative (TN), one FN, and one false positive (FP) finding. Diagnosis was made with SPECT in 2 patients. From 7 patients with neuroendocrine pancreatic carcinomas there were 4 TP and 3 TN findings. Diagnosis was made with SPECT in 2 patients. From 3 patients with gastrinomas there were 2 TP findings and one TN findings. Diagnosis was made with SPECT findings in 2 patients. Sensitivity of (99m)Tc-HYNIC-TOC was 87%, specificity 86%, positive predictive value 95%, negative predictive value 67% and accuracy 87%. CONCLUSION: We concluded that scintigraphy with (99m)Tc-Tektrotyd is an useful method for diagnosis, staging and follow up of the patients with NETs.


Subject(s)
Neuroendocrine Tumors/diagnostic imaging , Octreotide/analogs & derivatives , Organotechnetium Compounds , Tomography, Emission-Computed, Single-Photon/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Neoplasm Staging , Neuroendocrine Tumors/pathology
7.
J BUON ; 17(4): 695-9, 2012.
Article in English | MEDLINE | ID: mdl-23335527

ABSTRACT

PURPOSE: The aim of this study was to evaluate the clinical reliability of the immunoscintigraphy with iodinated monoclonal antibodies for the detection of metastases and recurrences of colon carcinomas. METHODS: A total of 45 patients with colon carcinoma was investigated with gamma camera, after intravenous application of iodinated monoclonal antibodies. RESULTS: The sensitivity of the method was 90%, specificity 86%, positive predictive value 93%, negative predictive value 80% and accuracy 87%. There was statistically significant relationship between immunoscintigraphic and ultrasonographic (US) findings (p=0.005). Also, there was significant relationship between immunoscintigraphy and Dukes stage (p=0.019). Tumor marker levels were not significantly correlated with immunoscintigraphic findings (p<0.05). Significant difference was noted in patients with positive findings for malignancy on US and immunoscintigraphic findings (p=0.006), i.e. patients with positive findings for malignancy had more frequently immunoscintigraphic findings of malignancy. Correlation with other diagnostic procedures (rectoscopy, colonoscopy, CT) did not show significant correlations. CONCLUSION: We conclude that immunoscintigraphy can be helpful in the detection of metastases and recurrences of colon carcinomas.


Subject(s)
Colonic Neoplasms/diagnostic imaging , Iodine Radioisotopes , Radioimmunodetection/methods , Adult , Aged , Antibodies, Monoclonal , Female , Humans , Male , Middle Aged
8.
Neoplasma ; 57(1): 68-73, 2010.
Article in English | MEDLINE | ID: mdl-19895175

ABSTRACT

UNLABELLED: Our aim was to assess clinical utility of 99mTc-EDDA/HYNIC-TOC scintigraphy for evaluation of lung lesions in patients with neuroendocrine tumors (NETs). Single photon emission computed tomography (SPECT) of the thorax and whole body scintigraphy were performed in 34 patients using 99mTc-EDDA/HYNIC-TOC. Visual assessment was complemented by semiquantitative evaluation based on tumor to non-tumor (T/NT) ratio. Clinical, laboratory, and histological findings served as the standard for comparison. Enhanced tracer uptake was observed on both SPECT and whole body scintigraphy in 29 of 34 patients (88% sensitivity). T/NT ratios were significantly higher on SPECT than whole body images (2.96+/-1.07 vs.1.70+/-0.43, p KEYWORDS: 99mTc-EDDA/Hynic-TOC, lung involvement of NETs, T/NT ratio.


Subject(s)
Lung Neoplasms/diagnostic imaging , Neuroendocrine Tumors/diagnostic imaging , Organotechnetium Compounds , Radiopharmaceuticals , Tomography, Emission-Computed, Single-Photon/methods , Adult , Aged , Cell Proliferation , Female , Humans , Ki-67 Antigen/analysis , Lung Neoplasms/pathology , Lung Neoplasms/radiotherapy , Male , Middle Aged , Neuroendocrine Tumors/pathology , Neuroendocrine Tumors/radiotherapy , Whole Body Imaging
9.
Neoplasma ; 56(1): 1-8, 2009.
Article in English | MEDLINE | ID: mdl-19152238

ABSTRACT

Immunoscintigraphy combines the advances in immunology and nuclear medicine to target tumor sites. Visualization of colorectal carcinomas is based on different monoclonal antibodies and their fragments against tumor-associated antigens labeled with gamma emitting radionuclides which accumulate in the tumor tissue due to their interaction with corresponding antigens. Available data on the role of immunoscintigraphy in detection of recurrence and metastases of colorectal carcinomas are reviewed. Despite a variety of investigations related to the application of immunoscintigraphy in diagnostics of colorectal cancer, using different radiolabeled immunoreactive agents and imaging methods there has not been a consensus among the investigators regarding the best modality of the method, including the specific radiopharmaceutical for this purpose. Some general conclusions concerning potentials of immunoscintigraphy in such diagnostics, including expectancy of the newly developed SPECT/CT systems, are suggested. The possibilities of PET imaging of colorectal carcinomas using monoclonal antibodies labeled with positron emitting radionuclides, as well as of the radioimmunoguided surgery and radioimmunotherapy are also discussed. Key words: Immunoscintigraphy, colorectal cancer, recurrences, metastases, radioimmunoguided surgery, SPECT/CT.


Subject(s)
Colorectal Neoplasms/diagnostic imaging , Radioimmunodetection/methods , Radionuclide Imaging/methods , Antibodies, Monoclonal , Humans , Radiopharmaceuticals
10.
Acta Chir Iugosl ; 55(1): 11-6, 2008.
Article in English | MEDLINE | ID: mdl-18510056

ABSTRACT

The aim of this study is the assessment of the relative arterial and venous contribution to the total liver blood flow (hepatic perfusion index-HPI), with two methods (S1 and S2), and estimation of their value. With this correction, HPI nonsignificantly increases (p>0.05) in all the groups of patients, with a very high correlation between the HPI (S1) and HPI (S2) values (p<0.01). In comparison to the portal perfusion in controls, values were significantly (p<0.01) lower in chronic active hepatitis and liver cirrhosis and differed between themselves (p<0.01). In the groups of cirrhotic patients with esophageal varices, sclerosated esophageal varices, recanalized umbilical vein, portal thrombosis and cavernous portal vein, portal perfusion was lower (p<0.01) than in controls, chronic active hepatitis and liver cirrhosis without collaterals. Both angioscintigraphic methods are useful for the estimation of the disturbances in the portal system. Because of the more exact estimation of the liver perfusion, S2 is recommended.


Subject(s)
Liver Circulation , Portal System/diagnostic imaging , Esophageal and Gastric Varices/etiology , Esophageal and Gastric Varices/physiopathology , Hepatitis, Chronic/complications , Hepatitis, Chronic/diagnostic imaging , Hepatitis, Chronic/physiopathology , Humans , Hypertension, Portal/diagnostic imaging , Hypertension, Portal/etiology , Hypertension, Portal/physiopathology , Liver Cirrhosis/complications , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/physiopathology , Radionuclide Angiography , Venous Thrombosis/diagnostic imaging , Venous Thrombosis/physiopathology
11.
Neoplasma ; 53(5): 444-9, 2006.
Article in English | MEDLINE | ID: mdl-17013541

ABSTRACT

The aim of the study was evaluation of the clinical reliability of the immunoscintigraphy for the detection of metastases and recurrences of colorectal carcinomas using three different radiopharmaceutical substances. With IMACIS 1, the number of true negative findings (TN) was 4/7 and true positive (TP) 3/7, while in one patient, the results of immunoscintigraphy significantly influenced the therapeutical management. With INDIMACIS 19-9, there were 2/8 TN and 6/8 TP. In three patients, immunoscintigraphy results influenced patient further management. With ONCOSCINT in 2 patients findings were TN, in one FN and in one FP. In 3 patients, immunoscintigraphy influenced the management of the patient. Other imaging methods (CT, US, MRI) have advantage in detection of liver metastases, while immunoscintigraphy is more specific for the assessment of reccurences of the abdominal tumors. Thus immunoscintigraphy should be applied in patients with suggested recurrences and inconclusive outcome of routine diagnostic workup.


Subject(s)
Adenocarcinoma/diagnostic imaging , Colorectal Neoplasms/diagnostic imaging , Neoplasm Metastasis/diagnostic imaging , Neoplasm Recurrence, Local/diagnostic imaging , Radioimmunodetection/methods , Radiopharmaceuticals , Antibodies, Monoclonal , Humans , Indium Radioisotopes , Sensitivity and Specificity
12.
Acta Chir Iugosl ; 53(1): 23-7, 2006.
Article in Serbian | MEDLINE | ID: mdl-16989142

ABSTRACT

The aim of the study is evaluation of hepatocellular function, as well as morphology and patency of the biliary three of the liver transplants by dynamic hepatobiliary scintigraphy. The study was performed in 10 controls and 10 patients after orthotopic transplantation (up to two years). Sixty minutes dynamic acquisition (1 frame/min) was performed with scintillation camera after injection of 360 MBq 99mTc-diethyl- IDA. Hepatobiliary scintigrams were analysed for morphology, and parenchymal and hepatobiliary TA curves were generated and analysed as regard to the time to maximal acitivity (Tmax) and the time to half of maximum acitivity (T1/2). Uptake of the radiopharmaceutical was slightly but not significantly delayed (Tmax=18.5 +/- 2.9 min) in comparison to the controls (Tmax=14.2 +/- 3.4min), while excretion was significantly prolonged (T1/2=59.5 +/- 12.1 min) than physiological (Tmax=34.2 +/- 4.1min). Intrahepatic bile flow was nonsignificantly prolonged (Tmax=31.3 +/- 3.7 min) in comparison to the controls (Tmax=25.7 +/- 3.5 min) while extrahepatic one is high significantly prolonged (T1/2=89.0 +/- 14.3 min) than physiological (T1/2 =45.0 +/- 7.2 min). Biliary phase of hepatobiliary scintigraphy showed increased accumulation of radiopharmaceutical in the left (n=1) or right (n=2) hepatic duct. Radionuclide methods are noninvasive, and apear to be sensitive and valuable for the monitoring of liver transplants.


Subject(s)
Biliary Tract/diagnostic imaging , Liver Transplantation/diagnostic imaging , Liver/diagnostic imaging , Humans , Liver/physiopathology , Radionuclide Imaging , Radiopharmaceuticals , Technetium Tc 99m Diethyl-iminodiacetic Acid
13.
Clin Lab Haematol ; 28(5): 317-20, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16999722

ABSTRACT

We report the case of a littoral-cell angioma of the spleen, a recently described benign vascular tumour, whose imaging and pathological characteristics have been discussed only by a few authors. The diagnosis was made after elective splenectomy. The CT images, scintigraphy and histological specimens are presented, and differential diagnoses discussed.


Subject(s)
Hemangioma/complications , Splenic Neoplasms/complications , Splenomegaly/etiology , Adult , Gated Blood-Pool Imaging , Hemangioma/pathology , Hemangioma/surgery , Histocytochemistry , Humans , Male , Splenectomy , Splenic Neoplasms/pathology , Splenic Neoplasms/surgery , Splenomegaly/pathology , Thrombocytopenia/etiology , Tomography, X-Ray Computed
14.
Hepatogastroenterology ; 52(62): 491-5, 2005.
Article in English | MEDLINE | ID: mdl-15816464

ABSTRACT

BACKGROUND/AIMS: The aim of the study is detection and evaluation of the abdominal and gastrointestinal infective foci using 99mTc-ciprofloxacin (Laboratory for radioactive isotopes, Vinca). METHODOLOGY: In total 21 patients with clinical suspicion on abdominal or gastrointestinal infection were investigated. In all the patients, planar liver/spleen scintigraphy was performed. Ciprofloxacin chloride (3.5 mg) was mixed with 555 MBq of 99mTc in 3 mL of physiological solution and incubated for 20 min. After slow i.v. injection in a cubital vein, dynamic acquisition (1 f/min) was performed during the first 60 min in the position of interest, followed by static acquisition (500,000 imp) anterior and posterior view, abdomen and pelvis after 1 h and 4 h in all patients. When necessary, additional scintigrams were acquired after 24 h. In all the patients with negative or equivocal findings of planar scintigraphy, emission computerized tomography (SPECT) was performed (60 positions, 6 degrees). Interpretation was made by three independent observers. Additional data were provided using clinical findings, ultrasonography, computed tomography and magnetic resonance imaging, laboratory analyses, and surgical or microbiological confirmation of infection. RESULTS: There were eleven true-positive findings, seven true negative, two were false negative while one was false positive due to intestinal obstruction. Sensitivity was 79%, specificity 91%, positive predictive value 92%, negative predictive value 77%, accuracy 84%. CONCLUSIONS: According to our results, scintigraphy with radiolabeled ciprofloxacin is a useful method for detection and assessment of exact localization of abdominal and gastrointestinal infections.


Subject(s)
Abdomen/diagnostic imaging , Bacterial Infections/diagnostic imaging , Ciprofloxacin/analogs & derivatives , Gastrointestinal Diseases/diagnostic imaging , Organotechnetium Compounds , Bacterial Infections/metabolism , Ciprofloxacin/pharmacokinetics , False Negative Reactions , False Positive Reactions , Gastrointestinal Diseases/metabolism , Humans , Liver/diagnostic imaging , Liver/metabolism , Organotechnetium Compounds/pharmacokinetics , Predictive Value of Tests , Radionuclide Imaging , Sensitivity and Specificity , Spleen/diagnostic imaging , Spleen/metabolism , Tissue Distribution
15.
Hepatogastroenterology ; 50(52): 1029-31, 2003.
Article in English | MEDLINE | ID: mdl-12845972

ABSTRACT

BACKGROUND/AIMS: The aim of the study is detection of the recurrences and metastases of colorectal carcinomas using 111In-labeled antibodies B72.3. METHODOLOGY: Fourteen patients underwent planar immunoscintigraphy and/or tomoscintigraphy. RESULTS: With tomography in comparison to planar scintigraphy, we can access better distinction of tumor and estimation of its size. Other imaging methods (computed tomography, ultrasonography) have an advantage in detection of liver metastases, while immunoscintigraphy is more specific for the assessment of malignant abdominal tumors and extrahepatic metastases. CONCLUSIONS: The first results point out that Oncoscint CR-103 can be useful in diagnosis of recurrences and metastases of colorectal carcinoma, viability assessment after radiotherapy and in the choice of the adequate surgical treatment in dependence of the spread of the disease.


Subject(s)
Adenocarcinoma/diagnostic imaging , Antibodies, Monoclonal , Colorectal Neoplasms/diagnostic imaging , Indium Radioisotopes , Neoplasm Recurrence, Local/diagnostic imaging , Oligopeptides , Pentetic Acid/analogs & derivatives , Radioimmunodetection , Carcinoma, Squamous Cell/diagnostic imaging , Colorectal Neoplasms/pathology , Humans , Peritoneal Neoplasms/diagnostic imaging , Peritoneal Neoplasms/secondary
16.
Acta Chir Iugosl ; 50(4): 43-6, 2003.
Article in Serbian | MEDLINE | ID: mdl-15307496

ABSTRACT

The aim of the study is detection of the recurrences and metastases of colorectal carcinomas using (111)In labelled antibodies B72.3 in 14 patients. With tomography, we can access better distinction of tumour in comparison to other structures and estimation of its size. Other imaging methods (CT, US) have advantage in detection of liver metastases, while immunoscintigraphy is more specific for the assessment of malignant abdominal tumours and extrahepatic metastases. The first results point out that Oncoscint CR-103 can be useful in diagnosis of recurrences and metastases of colorectal carcinoma, viability assessment after radiotherapy and in the choice of the adequate surgical treatment in dependence of the spread of the disease.


Subject(s)
Adenocarcinoma/diagnostic imaging , Antibodies, Monoclonal , Carcinoma, Squamous Cell/diagnostic imaging , Colorectal Neoplasms/diagnostic imaging , Indium Radioisotopes , Oligopeptides , Pentetic Acid/analogs & derivatives , Radioimmunodetection , Adenocarcinoma/secondary , Carcinoma, Squamous Cell/secondary , Colorectal Neoplasms/pathology , Humans , Neoplasm Recurrence, Local/diagnostic imaging
17.
Acta Chir Iugosl ; 50(2): 25-9, 2003.
Article in Croatian | MEDLINE | ID: mdl-14994566

ABSTRACT

The aim of the study is detection of the abdominal infective foci using 99mTc-ciprofloxacin, radiopharmaceutical supposed to distinguish inflammation from infection. Twenty-one patient was investigated. There were 11 true positive findings, 7 true negative, two were false negative, while 1 was false positive. Sensitivity of the method was 79% and specificity 91%. According to our results, scintigraphy with infection is a useful method for detection and assessment of exact localization of deep seated bacterial infections, which might be useful for (differential) diagnosis, surgical treatment in due time as well as monitoring of the treatment of conservative therapy.


Subject(s)
Abdomen/diagnostic imaging , Anti-Infective Agents , Bacterial Infections/diagnostic imaging , Ciprofloxacin , Technetium , Abdominal Abscess/diagnostic imaging , Abdominal Abscess/drug therapy , Anti-Infective Agents/therapeutic use , Ciprofloxacin/therapeutic use , Humans , Radionuclide Imaging , Sensitivity and Specificity
18.
Acta Chir Iugosl ; 49(3): 81-4, 2002.
Article in Croatian | MEDLINE | ID: mdl-12587454

ABSTRACT

Spleen is being surgically removed because of trauma, in diagnostic and-or therapeutical purposes because of the benignant and malignant diseases. The percentage of morbidity during and after splenectomy is relatively low. During surgery might occur bleeding, trauma of the pancreatic tail, stomach, lineal flexure of the colon, left hemidiafragm, left suprarenal gland and upper pole of the left kidney, which must be correspondingly reclaimed during the same intervention. In the early postoperative period, postoperative bleeding, subfrenic abscess, pulmonal atelectasis, bronchopneumonia and left pleural extravasations might occur. Especially is important notification of these events in due time and adequate conservative and surgical treatment. After splenectomy, there is an increase of the number of trombocytes, which might lead to the tromboembolic complications. In the prevention of these complications in the postoperative period prolonged antiagregation therapy is suggested. Postsplenectomy sepsis is very late, general complication of splenectomy, which occurs because of the lower immunity in the child age. To prevent these complications, partial splenectomies, reimplantations of the spleen, prolonged application of the penicillin medicines after splenectomy and antipneumococcal vaccine are performed.


Subject(s)
Intraoperative Complications , Postoperative Complications , Splenectomy/adverse effects , Humans
19.
Acta Chir Iugosl ; 49(3): 101-6, 2002.
Article in Croatian | MEDLINE | ID: mdl-12587457

ABSTRACT

Auto transplantation of the spleen can be performed in the patients with traumatic rupture of the spleen, in whom spleen could not be conserved in the other way. The right indication for this method is isolated rupture of the spleen (concvasation or complete devascularisation). This method is not recommended in the endangered patients, patients with previous disease of the spleen as well as in the patients with the perforation of the other abdominal organs at the same time. Auto transplantation was performed in 12 patients with isolated splenic rupture and hematoperitoneum, 11 men and one woman. The majority of patients are younger. In 8 patients, autotransplant was placed into big omentum, in three into lipomatous tissue surrounding left kidney, and in one into anterior abdominal wall. In all the patients from this group, following analysis were taken: MCV (middle volume of erythrocytes), HTC, Hb, Le, Glucose, urea, creatinin, sodium, potassium, alkali phosphatasis, target cells, Howell Jolly's bodies, Heinz's bodies, IgG, IgA, IgM, C3, C4, T3, T4, T8, B, segmentated, eosinophiles, lymphocytes, reticulocytes, thrombocytes, fibrinogen, PT, APTT, aggregation of thrombocytes and aggregation of thrombocytes on collagen. The same parameters were taken in 12 patients with surgery similar to splenectomy and in 12 after splenectomy. After splenectomy, there was decrease of the immunologic defending abilities of the organism because of the loss of the childrens function of the spleen, decreased level of the opsonines and tutsin, which leads to the impaired phagocytosis, decreased concentration of IgM and T and B lymphocytes, while in patients after auto transplantation the results were physiological. The most important thing in the assessment of the function of the autotransplanted spleen is scintigraphic investigation using 99mTc-denaturated red blood cells. In our study, auto transplant function was assessed in 10/12 patients by scintigraphy. Five years after surgery, no one patient was proved to have postsplenectomic sepsis.


Subject(s)
Spleen/transplantation , Splenic Rupture/surgery , Transplantation, Autologous/methods , Transplantation, Heterotopic/methods , Female , Follow-Up Studies , Humans , Male , Spleen/injuries , Splenectomy
20.
Acta Chir Iugosl ; 48(1): 25-9, 2001.
Article in Croatian | MEDLINE | ID: mdl-11432249

ABSTRACT

Hepatic radionuclide angiography (HRA) is a recognised method of investigation of liver blood flow disorders caused by: diffuse and focal diseases of liver parenchyma or disorders of blood flow in extrahepatic liver vessels. Hepatic perfusion index (HPI) based on Sarper's slope method is significantly lower in patients with e.g. liver cirrhosis, malignant primary and metastatic liver diseases and portal vene thrombosis, but not in patients with benign focal liver leasions. Determined in liver as a whole, HPI is a sensitive indicator of the presence of malignant liver tumours, but is within normal range in patients with hepatic hemangioma. The aim of the study was to investigate characteristic of blood flow in hemangioma itself, separately from but in relation to the liver blood flow, using hepatic radionuclide angiography. We have examined 12 patients with liver hemangioma confirmed mainly by positive 99mTc-labeled red blood cell scintigraphy, which diagnostic specificity for liver hemangiomas is near 100%. 8/12 hemangiomas resulted in photopenic areas on angioscintigrams, indicating lower blood flow, and rest were isoactive to surrounding liver tissue. Regions of interest have been delineated around the photopenic areas (hemangiomas) and surrounding liver tissue. Time-activity curves have been generated and slope of the fitted hepatic artery and (portal) venous portions of the hemangioma and liver curves have been determined. Perfusion indexes of hemangioma (PIH) and liver (HPI) have been calculated from the slopes, expressing portal venous flow as a portion of entire blood flow to the region. In addition, times of arrival and transit of intravenous bolus of 99mTc-pertechnetate through the hemangioma and liver tissue have also been derived from time-activity curves. Slope of the venous portion of the hemangioma time-activity curve is significantly lower then that of the venous portion of the liver curve (p < 0.01). So that, perfusion index of hemangioma (PIH = 0.34 +/- 0.12 (mean +/- SD) is significantly lower then hepatic perfusion index (HPI = 0.57 +/- 0.08) (p < 0.05). Bearing in mind interference of superimposed liver activity with that of hemangioma, these results indicate that liver hemangiomas are dominantly if not exclusively irrigated by hepatic artery branches. There are no data regarding relation between arterial and venous blood flow in liver hemangiomas determined by HRA. Obtained results are in harmony with arteriography data which confirm slow arterial blood flow through hemangiomas. Portal venous inflow of some angiomatous liver lesions in infants and children, and arterio-portal shunting in hemangiomas have been rarely reported. Results of this study indicate that regional determination of perfusion index and other HRA parameters in patients with focal liver lesion enables differentiation between tissues with different intensity and pattern of blood flow. The method could be used in examination of vascularisation pattern of other focal liver lesions.


Subject(s)
Erythrocytes , Hemangioma/blood supply , Liver Neoplasms/blood supply , Radiopharmaceuticals , Sodium Pertechnetate Tc 99m , Hepatic Artery/diagnostic imaging , Hepatic Veins/diagnostic imaging , Humans , Radionuclide Imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...