Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J AOAC Int ; 99(3): 676-85, 2016 May.
Article in English | MEDLINE | ID: mdl-27297838

ABSTRACT

In 2013, the Thermo Scientific™ SureTect™ Listeria monocytogenes Real-Time PCR Assay was certified by the AOAC Research Institute (RI) Performance Tested Methods(SM) program as a rapid method for the detection of L. monocytogenes from a wide range of food matrixes and surface samples. This report details the method modification studies undertaken to extend the analysis of this PCR assay to the Applied Biosystems™ 7500 Fast PCR Instrument and Applied Biosystems RapidFinder™ Express 2.0 software allowing the use of the SureTect assay on a 96 well format PCR cycler in addition to the current workflow, which uses the 24 well Thermo Scientific PikoReal™ PCR Instrument and Thermo Scientific SureTect software. Because this study was deemed by AOAC-RI to be a level 2 method modification study, a representative range of food matrixes covering raw ground turkey, 2% fat pasteurized milk, and bagged lettuce as well as stainless steel surface samples were analyzed with the Applied Biosystems 7500 Fast PCR Instrument and RapidFinder Express 2.0 software. All testing was conducted in comparison to the reference method detailed in International Organization for Standardization (ISO) 6579:2002. No significant difference by probability of detection statistical analysis was found between the SureTect Listeria monocytogenes PCR Assay or the ISO reference method methods for any of the matrixes analyzed during the study.


Subject(s)
Bacteriological Techniques/instrumentation , Listeria monocytogenes/genetics , Listeria monocytogenes/isolation & purification , Real-Time Polymerase Chain Reaction
2.
J AOAC Int ; 99(2): 407-16, 2016.
Article in English | MEDLINE | ID: mdl-26923177

ABSTRACT

The Thermo Scientific™ SureTect™ Listeria species Real-Time PCR Assay was certified during 2013 by the AOAC Research Institute (RI) Performance Tested Methods(SM) program as a rapid method for the detection of Listeria species from a wide range of food matrixes and surface samples. A method modification study was conducted in 2015 to extend the matrix claims of the product to a wider range of food matrixes. This report details the method modification study undertaken to extend the use of this PCR kit to the Applied Biosystems™ 7500 Fast PCR Instrument and Applied Biosystems RapidFinder™ Express 2.0 software allowing use of the assay on a 96-well format PCR cycler in addition to the current workflow, using the 24-well Thermo Scientific PikoReal™ PCR Instrument and Thermo Scientific SureTect software. The method modification study presented in this report was assessed by the AOAC-RI as being a level 2 method modification study, necessitating a method developer study on a representative range of food matrixes covering raw ground turkey, 2% fat pasteurized milk, and bagged lettuce as well as stainless steel surface samples. All testing was conducted in comparison to the reference method detailed in International Organization for Standardization (ISO) 6579:2002. No significant difference by probability of detection statistical analysis was found between the SureTect Listeria species PCR Assay or the ISO reference method methods for any of the three food matrixes and the surface samples analyzed during the study.


Subject(s)
Food Analysis , Food Microbiology , Listeria/genetics , Listeria/isolation & purification , Real-Time Polymerase Chain Reaction , Humans , Listeria/classification , Real-Time Polymerase Chain Reaction/standards , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL
...