Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
Europace ; 25(4): 1458-1466, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36857597

ABSTRACT

AIMS: Pacing remote from the latest electrically activated site (LEAS) in the left ventricle (LV) may diminish response to cardiac resynchronization therapy (CRT). We tested whether proximity of LV pacing site (LVPS) to LEAS, determined by non-invasive three-dimensional electrical activation mapping [electrocardiographic Imaging (ECGI)], increased likelihood of CRT response. METHODS AND RESULTS: Consecutive CRT patients underwent ECGI and chest/heart computed tomography 6-24 months of post-implant. Latest electrically activated site and the distance to LVPS (dp) were assessed. Left ventricular end-systolic volume (LVESV) reduction of ≥15% at clinical follow-up defined response. Logistic regression probabilistically modelled non-response; variables included demographics, heart failure classification, left bundle branch block (LBBB), ischaemic heart disease (IHD), atrial fibrillation, QRS duration, baseline ejection fraction (EF) and LVESV, comorbidities, use of CRT optimization algorithm, angiotensin-converting enzyme inhibitor(ACE)/angiotensin-receptor blocker (ARB), beta-blocker, diuretics, and dp. Of 111 studied patients [64 ± 11 years, EF 28 ± 6%, implant duration 12 ± 5 months (mean ± SD), 98% had LBBB, 38% IHD], 67% responded at 10 ± 3 months post CRT-implant. Latest electrically activated sites were outside the mid-to-basal lateral segments in 35% of the patients. dp was 42 ± 23 mm [31 ± 14 mm for responders vs. 63 ± 24 mm non-responders (P < 0.001)]. Longer dp and the lack of use of CRT optimization algorithm were the only independent predictors of non-response [area under the curve (AUC) 0.906]. dp of 47 mm delineated responders and non-responders (AUC 0.931). CONCLUSION: The distance between LV pacing site and latest electrical activation is a strong independent predictor for CRT response. Non-invasive electrical evaluation to characterize intrinsic activation and guide LV lead deployment may improve CRT efficacy.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Heart Ventricles/diagnostic imaging , Angiotensin Receptor Antagonists , Angiotensin-Converting Enzyme Inhibitors , Electrocardiography/methods , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Arrhythmias, Cardiac/therapy , Heart Failure/diagnosis , Heart Failure/therapy , Treatment Outcome , Ventricular Function, Left
3.
J Interv Card Electrophysiol ; 65(1): 167-177, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35575867

ABSTRACT

PURPOSE: Our study aimed to assess the achievement of target ablation index (AI) values and their impact on first-pass pulmonary vein isolation (FPI) as well as to identify FPI predictors. METHODS: Atrial fibrillation (AF) ablation was performed according to the local practice, and target AIs were evaluated. The actual AI was calculated as the median value of all ablation points for the anterior and posterior left atrial (LA) walls. RESULTS: A total of 450 patients from nine centers were enrolled. Patients with first-time ablation (n = 408) were divided into the FPI and non-FPI groups. In the FPI group, a higher median target AI was reported for both the anterior and posterior LA walls than those in the non-FPI group. A higher actual AI was observed for the anterior LA wall in the FPI group. The actual AI was equal to or higher than the target AI for the posterior, anterior, and both LA walls in 54%, 47%, and 35% (n = 158) cases, respectively. Parameters such as hypertension, stroke, ablation power, actual AI value on the anterior wall, target AI values on both LA walls, AI achievement on the posterior wall, carina ablation, and operator experience were all associated with FPI in a univariate logistic regression model; only carina ablation was an independent predictor of FPI. CONCLUSIONS: According to our multicenter study, FPI and a target AI were not achieved in a significant proportion of AF ablation procedures. Higher actual and target AI values were associated with FPI, but only carina ablation can independently predict FPI.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria/surgery , Humans , Pulmonary Veins/surgery , Recurrence , Registries , Treatment Outcome
4.
Cardiology ; 145(11): 730-735, 2020.
Article in English | MEDLINE | ID: mdl-33040058

ABSTRACT

This is a prospective multicenter registry of atrial fibrillation (AF) ablation with the Ablation Index (AI) technology, which has been introduced as a marker predicting ablation lesion depth. The index incorporates the main parameters of radiofrequency point-by-point ablation: power, contact force, and time of ablation. The AI is calculated for every operator depending on personal skills, and there are no strict indications on the range of the parameter considering its safety and efficacy during pulmonary vein isolation. The registry aims to evaluate AI values used in different centers by different operators and to evaluate the optimal limits associated with better acute and long-term AF ablation results.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/surgery , Humans , Prospective Studies , Pulmonary Veins/surgery , Registries
SELECTION OF CITATIONS
SEARCH DETAIL
...