Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Kardiologiia ; 61(1): 4-11, 2021 Feb 10.
Article in Russian, English | MEDLINE | ID: mdl-33734050

ABSTRACT

Aim      To evaluate the diagnostic accuracy of cardiac perfusion computed tomography (PCT) with transesophageal electrocardiostimulation (TE ECS) for detection of ischemia in patients with borderline coronary stenosis (50-75 %) compared to measurements of fractional flow reserve (FFR).Material and methods  The study included 25 patients with borderline (50-75 %) coronary stenosis as per data of computed tomography angiography (CTA) or coronary angiography (CAG). Later the patients underwent invasive measurement of FFR and cardiac PCT on a 320-row detector tomograph in combination with the TE ECS stress test.  FFR values <0.8 indicated the hemodynamic significance of stenosis. Myocardial perfusion was evaluated visually based on consensus of two experts.Results All patients completed the study protocol. Cardiac pacing duration was 6 min for all patients. Four patients required intravenous administration of atropine sulphate. PCT with TE ECS detected significant for FFR stenoses with sensitivity, specificity, and predictive value of a positive result and predictive value for a negative result of 47, 90, 87, and 53 %, respectively.Conclusion      PCT with TE ECS in combination with CTA can be considered as an informative method for simultaneous evaluation of the condition of coronary arteries and detection of myocardial ischemia. This method is particularly relevant for assessing the hemodynamic significance of borderline coronary stenoses.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Myocardial Perfusion Imaging , Constriction, Pathologic , Coronary Angiography , Coronary Stenosis/diagnosis , Coronary Vessels/diagnostic imaging , Exercise Test , Hemodynamics , Humans , Predictive Value of Tests
2.
Kardiologiia ; 59(5): 92-96, 2019 May 25.
Article in Russian | MEDLINE | ID: mdl-31131774

ABSTRACT

Radiofrequency ablation is the "gold standard" in atrial fibrillation treatment. The frequency of complications is about 3.5-3.9 %. The symptomatic pulmonary vein stenosis is one of the most severe complications. In this report we present a clinical case of stenosis of all four pulmonary veins after redo catheter ablation of atrial fibrillation in 61year-old patient, and discussion of possible causes, specific features of diagnosis, and possible approaches to treatment of this complication.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Constriction, Pathologic , Humans , Postoperative Complications , Radiofrequency Ablation/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...