Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Atmos Environ (1994) ; 243: 117871, 2020 Dec 01.
Article in English | MEDLINE | ID: mdl-32982566

ABSTRACT

The Jack Rabbit II Special Sonic Anemometer Study (JRII-S), a field project designed to examine the flow and turbulence within a systematically arranged mock-urban environment constructed from CONEX shipping containers, is described in detail. The study involved the deployment of 35 sonic anemometers at multiple heights and locations, including a 32 m tall, unobstructed tower located about 115 m outside the building array to document the approach wind flow characteristics. The purpose of this work was to describe the experimental design, analyze the sonic data, and report observed wind flow patterns within the urban canopy in comparison to the approaching boundary layer flow. We show that the flow within the building array follows a tendency towards one of three generalized flow regimes displaying channeling over a wide range of wind speeds, directions, and stabilities. Two or more sonic anemometers positioned only a few meters apart can have vastly different flow patterns that are dictated by the building structures. Within the building array, turbulence values represented by normalized vertical velocity variance ( σ w 2 ) are at least two to three times greater than that in the approach flow. There is also little evidence that σ w 2 measured at various heights or locations within the JRII array is a strong function of stability type in contrast to the approach flow. The results reinforce how urban areas create complicated wind patterns, channeling effects, and localized turbulence that can impact the dispersion of an effluent release. These findings can be used to inform the development of improved wind flow algorithms to better characterize pollutant dispersion in fast-response models.

2.
J Air Waste Manag Assoc ; 58(9): 1130-44, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18817106

ABSTRACT

Ammonia (NH3) fluxes from waste treatment lagoons and barns at two conventional swine farms in eastern North Carolina were measured. The waste treatment lagoon data were analyzed to elucidate the temporal (seasonal and diurnal) variability and to derive regression relationships between NH3 flux and lagoon temperature, pH and ammonium content of the lagoon, and the most relevant meteorological parameters. NH3 fluxes were measured at various sampling locations on the lagoons by a flowthrough dynamic chamber system interfaced to an environmentally controlled mobile laboratory. Two sets of open-path Fourier transform infrared (FTIR) spectrometers were also used to measure NH3 concentrations for estimating NH3 emissions from the animal housing units (barns) at the lagoon and spray technology (LST) sites. Two different types of ventilation systems were used at the two farms. Moore farm used fan ventilation, and Stokes farm used natural ventilation. The early fall and winter season intensive measurement campaigns were conducted during September 9 to October 11, 2002 (lagoon temperature ranged from 21.2 to 33.6 degrees C) and January 6 to February 2, 2003 (lagoon temperature ranged from 1.7 to 12 degrees C), respectively. Significant differences in seasonal NH3 fluxes from the waste treatment lagoons were found at both farms. Typical diurnal variation of NH3 flux with its maximum value in the afternoon was observed during both experimental periods. Exponentially increasing flux with increasing surface lagoon temperature was observed, and a linear regression relationship between logarithm of NH3 flux and lagoon surface temperature (T1) was obtained. Correlations between lagoon NH3 flux and chemical parameters, such as pH, total Kjeldahl nitrogen (TKN), and total ammoniacal nitrogen (TAN) were found to be statistically insignificant or weak. In addition to lagoon surface temperature, the difference (D) between air temperature and the lagoon surface temperature was also found to influence the NH3 flux, especially when D > 0 (i.e., air hotter than lagoon). This hot-air effect is included in the statistical-observational model obtained in this study, which was used further in the companion study (Part II), to compare the emissions from potential environmental superior technologies to evaluate the effectiveness of each technology.


Subject(s)
Agriculture , Air Pollutants, Occupational/analysis , Ammonia/analysis , Swine/physiology , Waste Disposal, Fluid/methods , Animals , Environmental Monitoring , North Carolina
3.
J Air Waste Manag Assoc ; 58(9): 1145-57, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18817107

ABSTRACT

The need for developing environmentally superior and sustainable solutions for managing the animal waste at commercial swine farms in eastern North Carolina has been recognized in recent years. Program OPEN (Odor, Pathogens, and Emissions of Nitrogen), funded by the North Carolina State University Animal and Poultry Waste Management Center (APWMC), was initiated and charged with the evaluation of potential environmentally superior technologies (ESTs) that have been developed and implemented at selected swine farms or facilities. The OPEN program has demonstrated the effectiveness of a new paradigm for policy-relevant environmental research related to North Carolina's animal waste management programs. This new paradigm is based on a commitment to improve scientific understanding associated with a wide array of environmental issues (i.e., issues related to the movement of N from animal waste into air, water, and soil media; the transmission of odor and odorants; disease-transmitting vectors; and airborne pathogens). The primary focus of this paper is on emissions of ammonia (NH3) from some potential ESTs that were being evaluated at full-scale swine facilities. During 2-week-long periods in two different seasons (warm and cold), NH3 fluxes from water-holding structures and NH3 emissions from animal houses or barns were measured at six potential EST sites: (1) Barham farm--in-ground ambient temperature anaerobic digester/energy recovery/greenhouse vegetable production system; (2) BOC #93 farm--upflow biofiltration system--EKOKAN; (3) Carrolls farm--aerobic blanket system--ISSUES-ABS; (4) Corbett #1 farm--solids separation/ gasification for energy and ash recovery centralized system--BEST; (5) Corbett #2 farm--solid separation/ reciprocating water technology--ReCip; and (6) Vestal farm--Recycling of Nutrient, Energy and Water System--ISSUES-RENEW. The ESTs were compared with similar measurements made at two conventional lagoon and spray technology (LST) farms (Moore farm and Stokes farm). A flow-through dynamic chamber system and two sets of open-path Fourier transform infrared (OP-FTIR) spectrometers measured NH3 fluxes continuously from water-holding structures and emissions from housing units at the EST and conventional LST sites. A statistical-observational model for lagoon NH3 flux was developed using a multiple linear regression analysis of 15-min averaged NH3 flux data against the relevant environmental parameters measured at the two conventional farms during two different seasons of the year. This was used to compare the water-holding structures at ESTs with those from lagoons at conventional sites under similar environmental conditions. Percentage reductions in NH3 emissions from different components of each potential EST, as well as the whole farm on which the EST was located were evaluated from the estimated emissions from water-holding structures, barns, etc., all normalized by the appropriate nitrogen excretion rate at the potential EST farm, as well as from the appropriate conventional farm. This study showed that ammonia emissions were reduced by all but one potential EST for both experimental periods. However, on the basis of our evaluation results and analysis and available information in the scientific literature, the evaluated alternative technologies may require additional technical modifications to be qualified as unconditional ESTs relative to NH3 emissions reductions.


Subject(s)
Agriculture , Air Pollutants, Occupational/analysis , Ammonia/analysis , Swine/physiology , Waste Disposal, Fluid/methods , Animals , North Carolina
4.
J Air Waste Manag Assoc ; 58(9): 1198-207, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18817112

ABSTRACT

A modeling study was conducted on dispersion and dry deposition of ammonia taking one hog farm as a unit. The ammonia emissions used in this study were measured under our OPEN (Odor, Pathogens, and Emissions of Nitrogen) project over a waste lagoon and from hog barns. Meteorological data were also collected at the farm site. The actual layout of barns and lagoons on the farms was used to simulate dry deposition downwind of the farm. Dry deposition velocity, dispersion, and dry deposition of ammonia were studied over different seasons and under different stability conditions using the short-range dispersion/air quality model, AERMOD. Dry deposition velocities were highest under near-neutral conditions and lowest under stable conditions. The highest deposition at short range occurred under nighttime stable conditions and the lowest occurred during daytime unstable conditions. Significant differences in deposition over crop and grass surfaces were observed under stable conditions.


Subject(s)
Agriculture , Air Pollutants, Occupational/analysis , Ammonia/analysis , Swine/physiology , Animals , Environmental Monitoring , Models, Statistical , North Carolina , Seasons , Weather
SELECTION OF CITATIONS
SEARCH DETAIL
...