Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Jpn J Radiol ; 42(2): 158-164, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37633874

ABSTRACT

Recently, computed tomography with photon-counting detector (PCD-CT) has been developed to enable high-resolution imaging at a lower radiation dose. PCD-CT employs a photon-counting detector that can measure the number of incident X-ray photons and their energy. The newly released PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) has been in clinical use at our institution since December 2022. The PCD-CT offers several advantages over current state-of-the-art energy-integrating detector CT (EID-CT). The PCD-CT does not require septa to create a detector channel, while EID-CT does. Therefore, downsizing the anode to achieve higher resolution does not affect the dose efficiency of the PCD-CT. CT is an indispensable modality for evaluating ear ossicles. The ear ossicles and joints are clearly depicted by PCD-CT. In particular, the anterior and posterior legs of the stapes, which are sometimes unclear on conventional CT scans, can be clearly visualized. We present cases of congenital anomalies of the ossicular chain, ossicular chain dislocation, tympanosclerosis, and cholesteatoma in which PCD-CT was useful. This short article reports the usefulness of PCD-CT in the 3D visualization of the ear ossicles.


Subject(s)
Radiographic Image Enhancement , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Radiographic Image Enhancement/methods , Photons , Ear Ossicles/diagnostic imaging
2.
Acta Med Okayama ; 77(6): 647-650, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38145939

ABSTRACT

A 67-year-old man was referred to our hospital for the diagnosis and treatment of prostate cancer. Multidisciplinary discussion led to intensity-modulated radiotherapy preceded by hormone therapy. Before radiotherapy, a biodegradable hydrogel spacer (HS) was placed between the prostate and rectum to reduce radiation injury risk. Three weeks postplacement, pelvic magnetic resonance imaging revealed HS migration into the pelvic vein. Subsequent whole-body contrast-enhanced computed tomography (CECT) revealed HS migration into the pulmonary artery. The patient showed no symptoms or clinical signs. Radiotherapy was completed uneventfully. Complete absorption of the migrated HS was confirmed using CECT images 5 months postplacement.


Subject(s)
Hydrogels , Prostatic Neoplasms , Male , Humans , Aged , Hydrogel, Polyethylene Glycol Dimethacrylate , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/pathology , Prostate/pathology , Rectum/pathology , Prostatic Neoplasms/pathology
3.
Abdom Radiol (NY) ; 47(6): 1929-1938, 2022 06.
Article in English | MEDLINE | ID: mdl-35226124

ABSTRACT

PURPOSE: This study aimed to investigate the characteristics of magnetic resonance imaging (MRI) findings in pure prostatic ductal adenocarcinoma. METHODS: From January 2009 to February 2020, seven patients who were diagnosed with pure prostatic ductal adenocarcinoma and had a referable preoperative MRI scan were included in the study. We evaluated the following MRI findings for each tumor: size, location, presence of multi-cystic component, and apparent diffusion coefficient (ADC) value. RESULTS: The median maximum diameter of the tumors was 22 mm (range 19-70 mm). Regarding transverse distribution, five tumors were located in the periurethral area and two were located peripherally apart from the urethra. Two of the seven tumors had cystic components. The median ADC value of the tumors was 0.754 × 10-3 mm2/s (range 0.570-0.963 × 10-3 mm2/s). Based on the transverse distribution and components of the tumors on MRI, ductal adenocarcinomas were classified into three types: type I as a non-cystic tumor located peripherally apart from the urethra (29%, two cases); type II as a non-cystic tumor located in the periurethral area (43%, three cases); and type III as a tumor with a multi-cystic component (29%, two cases). CONCLUSION: The non-cystic mass with periurethral distribution (type II) and multi-cystic mass (type III) may be characteristic features that differentiate pure ductal adenocarcinoma from ordinary acinar adenocarcinoma on MRI.


Subject(s)
Carcinoma, Acinar Cell , Prostatic Neoplasms , Carcinoma, Acinar Cell/pathology , Diffusion Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Male , Prostatic Neoplasms/pathology
4.
Jpn J Radiol ; 36(4): 285-294, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29429141

ABSTRACT

PURPOSE: The quality of images acquired using single-energy metal artifact reduction (SEMAR) on helical lung computed tomography (CT) in patients with pulmonary arteriovenous malformation (PAVM) after coil embolization was retrospectively evaluated. MATERIALS AND METHODS: CT images were reconstructed with and without SEMAR. Twenty-seven lesions [20 patients (2 males, 18 females), mean age 61.2 ± 11.0 years; number of embolization coils, 9.8 ± 5.0] on contrast-enhanced CT and 18 lesions of non-enhanced lung CT concurrently performed were evaluated. Regions of interest were positioned around the coils and mean standard deviation value was compared as noise index. Two radiologists visually evaluated metallic coil artifacts using a four-point scale: 4 = minimal; 3 = mild; 2 = strong; 1 = extensive. RESULTS: Noise index was significantly improved with SEMAR versus without SEMAR (median [interquartile range]; 194.4 [161.6-211.9] Hounsfield units [HU] vs. 243.9 [220.4-286.0] HU; p < 0.001). Visual score was significantly improved with SEMAR versus without SEMAR (Reader 1, 3 [3] vs.1 [1]; Reader 2, 3 [3] vs.1 [1]; p < 0.001). Significant differences were similarly demonstrated on lung CT (p < 0.001). CONCLUSION: SEMAR provided clear chest CT images in patients who underwent PAVM coil embolization.


Subject(s)
Arteriovenous Malformations/therapy , Artifacts , Blood Vessel Prosthesis , Embolization, Therapeutic/methods , Image Processing, Computer-Assisted/methods , Tomography, Spiral Computed/methods , Adult , Aged , Algorithms , Arteriovenous Malformations/diagnostic imaging , Contrast Media , Female , Humans , Lung/blood supply , Lung/diagnostic imaging , Male , Metals , Middle Aged , Radiographic Image Enhancement/methods , Reproducibility of Results , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...